Rachel Roos

Ms. Rachel Roos

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 October 2024 in Sensors
Verified
Journal Article
Open access
PDF file
ABAnna Bailes
Anna Bailes
MJMarit E Johnson
Marit E Johnson
RRRachel Roos
Rachel Roos
WCWilliam W Clark
William W Clark
HCHarold Allen Cook
Harold Allen Cook
KBKevin Bell
Kevin Bell
Inertial measurement units (IMUs) provide benefits over the traditional optoelectronic motion capture (OMC) systems in measuring kinematics for the low back pain population. The reliability and validity of IMUs to quantify three-dimensional motion for multiple hip/spine segments have not been systematically evaluated. The purpose of this study was to determine the repeated-measures reliability and concurrent validity of an IMU system for measuring the three-dimensional spine/hip kinematics in six common movement assessments. Seventeen participants (32.3 (14.7) years; 11 female) performed two trials each of six range-of-motion assessments while fitted with four IMUs (T1/T2, T12/L1, L5/S1, and femur). The IMUs showed good–excellent reliability for most of the movements in the primary plane and poor–moderate reliability in the non-primary planes. The IMU and OMC systems showed generally good–excellent agreement in the primary plane and RMSE values between 3.03° and 15.75°. The removal of outliers based on the Bland–Altman analysis resulted in RMSE values between 2.44° and 10.30°. The system agreement in the non-primary planes was generally poor–moderate, and the RMSE values ranged from 2.19° to 45.88°. Anomalies in the proprietary sensor fusion algorithm or calibration may have contributed to the large RMSE values, highlighting the importance of assessing data for physiological relevance. The results suggest that these IMUs may be best suited for population-based studies measuring movement in the primary plane and point toward the need for the development of more robust approaches for broader implementation.

18 June 2025 in Sensors
Verified
Journal Article
Open access
PDF file
RRRachel Roos
Rachel Roos
JLJennifer Lambiase
Jennifer Lambiase
MRMichelle Riffitts
Michelle Riffitts
LSLeslie Scholle
Leslie Scholle
SKSimran Kulkarni
Simran Kulkarni
KBKevin Bell
Kevin Bell
Rotator cuff tears are common in individuals over 40, and physical therapy is often prescribed post-surgery. However, access can be limited by cost, convenience, and insurance coverage. CuffLink is a telehealth rehabilitation system that integrates the Strengthening and Stabilization System mechanical exerciser with the interACTION mobile health platform. The system includes a triple-axis accelerometer (LSM6DSOX + LIS3MDL FeatherWing), a rotary encoder, a VL530X time-of-flight sensor, and two wearable BioMech Health IMUs to capture upper-limb motion. CuffLink is designed to facilitate controlled, home-based exercise while enabling clinicians to remotely monitor joint function. Concurrent validity and test–retest reliability were used to assess device accuracy and repeatability. The results showed moderate to good validity for shoulder rotation (ICC = 0.81), device rotation (ICC = 0.94), and linear tracking (from zero: ICC = 0.75 and RMSE = 2.41; from start: ICC = 0.88 and RMSE = 2.02) and good reliability (e.g., RMSEs as low as 1.66 cm), with greater consistency in linear tracking compared to angular measures. Shoulder rotation and abduction exhibited higher variability in both validity and reliability measures. Future improvements will focus on manufacturability, signal stability, and force sensing. CuffLink supports accessible, data-driven rehabilitation and holds promise for advancing digital health in orthopedic recovery.

17 October 2025 in Sensors
Verified
Journal Article
Open access
PDF file
CLConnor Luck
Connor Luck
RRRachel Roos
Rachel Roos
JLJennifer Lambiase
Jennifer Lambiase
MRMichelle Riffitts
Michelle Riffitts
LSLeslie Scholle
Leslie Scholle
MMMichael P. McClincy
Michael P. McClincy
Proper rehabilitation following rotator cuff repair (RCR) is necessary for successful postoperative outcomes, though the average course of physical therapy (PT) is lengthy and costly. The goals of this study were to (1) develop exercise programs for the CuffLink mHealth system and (2) evaluate early prototype efforts at meeting the needs of RCR clients. A panel of 24 clinicians participated in a Delphi study to identify consensus in rehabilitation, key informatic needs, and appropriate interface modalities for client usage. Utilizing the Delphi findings, the iA CuffLink mHealth system was developed, and a pilot evaluation assessed the feasibility and usability of CuffLink through the mHealth App Usability Questionnaire (MAUQ). During the pilot evaluation, the overall MAUQ score was 6.14. All participants (n = 18) viewed messaging the care team and a real time rep counter as “important” or “very important”. All participants either agreed or strongly agreed that quantifying progress would help motivate them to be compliant, and that the app helped them achieve their recovery outcomes compared to the shoulder device alone. Participants were generally pleased with the ease of use, information arrangement, and usefulness of CuffLink. These findings can advance our understanding of the informatics and usability needs in telerehabilitation systems.