Robson Pacífico Guimarães Lima

Prof. Robson Pacífico Guimarães Lima

Federal Institute of Pernambuco, Recife, Pernambuco, Brazil
+1
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 April 2022 in Sensors
Verified
Journal Article
Open access
PDF file
RLRobson Pacífico Guimarães Lima
Robson Pacífico Guimarães Lima
Juan Moises Mauricio VillanuevaJuan Moises Mauricio Villanueva
Juan Moises Mauricio Villanueva
HGHeber P. Gomes
Heber P. Gomes
TFThommas Flores
Thommas Flores
A water supply system is considered an essential service to the population as it is about providing an essential good for life. This system typically consists of several sensors, transducers, pumps, etc., and some of these elements have high costs and/or complex installation. The indirect measurement of a quantity can be used to obtain a desired variable, dispensing with the use of a specific sensor in the plant. Among the contributions of this technique is the design of the pressure controller using the adaptive control, as well as the use of an artificial neural network for the construction of nonlinear models using inherent system parameters such as pressure, engine rotation frequency and control valve angle, with the purpose of estimating the flow. Among the various contributions of the research, we can highlight the suppression in the acquisition of physical flow meters, the elimination of physical installation and others. The validation was carried out through tests in an experimental bench located in the Laboratory of Energy and Hydraulic Efficiency in Sanitation of the Federal University of Paraiba. The results of the soft sensor were compared with those of an electromagnetic flux sensor, obtaining a maximum error of 10%.

18 October 2023 in Anais Do Vi Simpósio Brasileiro de Sistemas Elétricos
Verified
Conference Paper
Open access
PDF file
RLRobson Pacífico Guimarães Lima
Robson Pacífico Guimarães Lima
Juan Moises Mauricio VillanuevaJuan Moises Mauricio Villanueva
Juan Moises Mauricio Villanueva
HGHeber P. Gomes
Heber P. Gomes
TFThommas Flores
Thommas Flores
AOAnne Louise Matos Barão Oliveira
Anne Louise Matos Barão Oliveira
The present work describes the methodologies used to evaluate the robustness of an adaptive controller used to promote pressure management in a water supply system when the system is subjected to chaotic inputs. Pressure is one of the most important quantities in supply systems and it directly impacts other associated variables such as flow for example. The standardization of pressure in the supply network, through control adjustment, can reduce the frequency of pipe ruptures, pressure-induced excessive water consumption and volume lost in leaks. To this end, the control technique used in this work was adaptive control. The analyzed controller, based on the technique, can change its gains from the dynamic changes that occur in the system over time, without necessarily having a previous data collection for the controller modeling. Tests were performed emulating chaotic inputs, such as spurious outliers and gaussian noises, likely to occur in water supply systems, to verify the controller's robustness to these inputs. The results obtained and analyzed proved the robustness of the controller, allowing a window of applicability in real supply systems.