Rodolfo Vitorino Ramalho

Ms. Rodolfo Vitorino Ramalho

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 June 2025 in Processes
Verified
Journal Article
Open access
PDF file
Rodolfo Vitorino RamalhoRodolfo Vitorino Ramalho
Rodolfo Vitorino Ramalho
MFManoel José Mangabeira Pereira Filho
Manoel José Mangabeira Pereira Filho
MSManoel José dos Santos Sena
Manoel José dos Santos Sena
RMRômulo Mendes
Rômulo Mendes
SNSiergberth Ugulino Neto
Siergberth Ugulino Neto
André Luiz Amarante MesquitaAndré Luiz Amarante Mesquita
André Luiz Amarante Mesquita
In the Amazon, nearly one million people remain without reliable access to electricity. Moreover, the rural electricity grid is a mostly single-phase, ground-return type, with poor energy quality and high expenses. This study examines very low-head micro-hydropower (MHP) sites in the Amazon, emphasizing the integration of multiple axial-flow turbines. It includes an analysis of flow duration curves and key curves, both upstream and downstream, to design an MHP plant with multiple units targeting maximized energy yield. The presence of multiple turbines is crucial due to the substantial annual flow variation in the Amazon rivers. One contribution of this work is its scalable framework for ultra-low-head and high flow variability in small rivers, which is applicable in similar hydrological configurations, such as those typical of the Amazon. The design applies the minimum pressure coefficient criterion to increase turbine efficiency. Computational Fluid Dynamics (CFD) simulations forecast turbine efficiency and flow behavior. The CFD model is validated using experimental data available in the literature on a similar turbine, which is similarly used in this study for cost reasons, with discrepancies under 5%, demonstrating robust predictions of turbine efficiency and head behavior as a function of flow. This study also explores the implications of including inlet guide vanes (IGVs). We use a case study of a small bridge in Vila do Janari, situated in the southeastern part of Pará state, where heads range from 1.4 to 2.4 m and turbine flow rates span from 0.23 to 0.92 m3/s. The optimal configuration shows the potential to generate 63 MWh/year.

3 November 2025 in Energy Conversion and Management
Verified
Journal Article
Closed access
TWT.M. Wanzeler
T.M. Wanzeler
Rodolfo Vitorino RamalhoRodolfo Vitorino Ramalho
Rodolfo Vitorino Ramalho
AMA.L. Amarante Mesquita
A.L. Amarante Mesquita
GFG.C. Andrade Furtado
G.C. Andrade Furtado

21 April 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
Rodolfo Vitorino RamalhoRodolfo Vitorino Ramalho
Rodolfo Vitorino Ramalho
MFManoel Pereira Filho
Manoel Pereira Filho
MSManoel Sena
Manoel Sena
RMRômulo Mendes
Rômulo Mendes
SNSiergberth Ugulino Neto
Siergberth Ugulino Neto
André Luiz Amarante MesquitaAndré Luiz Amarante Mesquita
André Luiz Amarante Mesquita
Nearly one million people in Amazon still don't have reliable access to electricity. Moreover, the rural electricity grid is mostly single-phase, ground-return type, with poor energy quality and high expenses. This study examines very low head micro hydro power (MHP) installations in Amazon, emphasizing the integration of multiple axial-flow turbines. It includes an analysis of flow duration curves and key curves, both upstream and downstream, to design an MHP with two or more units aimed at maximizing annual energy generation. The presence of multiple turbines is crucial due to the substantial annual flow variation in the Amazon rivers. This research supports the design of small, cost-effective axial-flow hydraulic turbines. The design applies the minimum pressure coefficient criterion to increase turbine efficiency. Computational Fluid Dynamics (CFD) simulations forecast turbine efficiency and flow behavior. The CFD model is validated against an existing experimental study from the literature on a propeller turbine with a curved plate blade, which is similarly used in this study due to cost reasons. The study also explores the implications of including inlet guide vanes (IGV). A case study is showcased for a location at a small bridge in Vila do Janari, situated in the southeastern part of Pará state, where heads range from 1.4 to 2.4 m and turbine flow rates span from 0.23 to 0.92 m³/s. The optimal configuration shows the potential to generate 63 MWh/year.

24 July 2023 in Brazilian Journal of Environmental Sciences
Verified
Journal Article
Open access
PDF file
IVIngrid Luna Baia Viana
Ingrid Luna Baia Viana
JBJamile Caroline Moreira Batista
Jamile Caroline Moreira Batista
JSJoão Henrique Macedo Sá
João Henrique Macedo Sá
Rodolfo Vitorino RamalhoRodolfo Vitorino Ramalho
Rodolfo Vitorino Ramalho
RLRaynner Menezes Lopes
Raynner Menezes Lopes
André Luiz Amarante MesquitaAndré Luiz Amarante Mesquita
André Luiz Amarante Mesquita
As redes de distribuição de água (WDN) são consideradas fonte renovável potencial, apresentando energia de pressão mais que suficiente para entregar água aos usuários. Para controlar a pressão excessiva, comumente as WDN são divididas em áreas de medição distrital (DMA), com válvulas redutoras de pressão (PRV). A energia desperdiçada pelas PRV pode ser recuperada por bombas como turbinas (PAT). Entretanto, a seleção da bomba adequada ainda é um desafio, pois devem-se considerar as mudanças diárias de pressão e vazão dos consumidores (off-design). Neste artigo, uma combinação de modelos foi validada e aplicada para selecionar a bomba adequada para operar em uma WDN real. A substituição de duas PRV por PAT de uma rede real previamente dividida em duas DMA, operando em velocidade constante, foi investigada. As análises econômica e ambiental também foram efetuadas. A PAT1 foi tecnicamente melhor que PAT2, que apresentou pressão de saída negativa, prejudicando a pressão na DMA2. As melhores eficiências só ocorrem nas vazões no melhor ponto de eficiência da bomba ou próximo a ele, reproduzindo o controle da pressão como se fossem as próprias válvulas. A melhor bomba recuperou 4.331 kWh/ano, o equivalente à redução de 1.732.400 gCO2/ano, atendendo duas casas categorizadas como baixa renda. A utilização de PAT mostrou-se uma alternativa viável, com período de retorno de 2,1 anos, uma vez que é capaz de recuperar a energia renovável. Contudo, para o controle efetivo da pressão em WDN, devem-se buscar outras estratégias de operação, como a operação em velocidade variável.

1 February 2024 in Journal of Applied Fluid Mechanics
Verified
Journal Article
Open access
PDF file
Rodolfo Vitorino RamalhoRodolfo Vitorino Ramalho
Rodolfo Vitorino Ramalho
AMA. L. Amarante Mesquita
A. L. Amarante Mesquita
NFN. Manzanares Filho
N. Manzanares Filho
An analysis of the minimum pressure coefficient on the suction side of the axial-flow pump blades is presented as a design criterion. A Matlab code is used to improve the computer aided design process efficiency and quality. X-Foil software determines the blade profiles' lift and drag coefficients, and a computational fluid dynamics model is applied to certify the pump efficiency. The model is validated from the available experimental data in the literature. The finite volume method is used through the commercial software Ansys CFX, in order to solve the model equations. A case study is presented to design the axial-flow pump for a large circulating water channel that will be used to test ships, naval structures, and hydrokinetic turbines. Particular attention is given to the pump cavitation conditions. The model evaluates the minimum pressure coefficient criterion and pressure coefficient distribution on the blade span, showing satisfactory performance for the pump at the design point and at variable speed.