Roozbeh Torkzadeh

Mr. Roozbeh Torkzadeh

Esfahan Regional Electric Company

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 July 2019 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
ASArash Safavizadeh
Arash Safavizadeh
MKMeysam Kordi
Meysam Kordi
FEFariborz Eghtedarnia
Fariborz Eghtedarnia
RTRoozbeh Torkzadeh
Roozbeh Torkzadeh
HMHesamoddin Marzooghi
Hesamoddin Marzooghi
Development of phasor measurement units (PMUs) and wide‐area measurement systems in power systems has enabled transmission system operators to monitor and assess the performance of their grids in real‐time. In this study, a new practical method is proposed and prototyped for real‐time monitoring of transient and short‐term voltage stability using synchrophasor data obtained from PMUs. In the previous related studies, methods for detecting rotor angle and voltage instabilities were presented regardless of how they can be implemented and exploited in real settings. In this study, the authors present a framework considering practical concerns, such as noise of measurements and software requirements. The well‐known Lyapunov exponent (LE) concept is used in the heart of the authors’ methodology. Their methodology uses time‐series data obtained from PMUs for calculating LEs, and by averaging the latest data packages received in the control centre, the performance of their framework is significantly improved under noisy measurements. As the framework is mission‐critical, they considered a suitable architecture merged with a flexible human–computer interaction with the goals of increasing security, reliability, resilience, robustness, and efficiency. Simulation results demonstrate the capability of their framework in fast and accurate assessment of short‐term stability using the IEEE 9‐bus and 69‐bus test systems.

1 May 2014
Verified
Conference Paper
Closed access
RTRoozbeh Torkzadeh
Roozbeh Torkzadeh
AMAhmad Mirzaei
Ahmad Mirzaei
MMMohammad Mehdi Mirjalili
Mohammad Mehdi Mirjalili
AAAlireza Sedighi Anaraki
Alireza Sedighi Anaraki
MSMohammad Reza Sehhati
Mohammad Reza Sehhati
FBFarideh Behdad
Farideh Behdad
An accurate medium term load forecast (MTLF) is essential for expansion planning studies of distribution systems. Also the mid-term electric load as a function of time has a complex nonlinear behavior which makes the ordinary linear prediction methods seems insufficient. In this paper, a combination of multi linear regression and principle components analysis is used to predict weekly electrical peak load of Yazd city distribution system. According to the prediction results, main benefits of proposed method are simplicity of calculations and high accuracy forecasting for multi-horizon predictions. MATLAB© is used to implement the forecaster model.

27 April 2018 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
BABabak Ahmadzadeh‐Shooshtari
Babak Ahmadzadeh‐Shooshtari
RTRoozbeh Torkzadeh
Roozbeh Torkzadeh
MKMeysam Kordi
Meysam Kordi
HMHesamoddin Marzooghi
Hesamoddin Marzooghi
FEFariborz Eghtedarnia
Fariborz Eghtedarnia
In this study, first, it is shown that the least‐squares (LS) algorithm outperforms well known methods such as extended Kalman filter and unscented Kalman filter for synchronous generator (SG) parameters estimation using phasor measurement unit (PMU) data. However, as the LS algorithm may estimate the SG parameters inaccurately if the initial values of SG model state variables are not valid, a modified LS (MLS) algorithm, which estimates the initial values of SG model state variables alongside SG parameters, is proposed. In addition to parameters estimation of an SG classical model, the performance of this algorithm in the estimation of whole electromagnetic parameters and rotor inertia constant of an SG full‐order model is evaluated. Note that conventionally, measurements of generators rotor angles were used to estimate SGs full‐order model parameters; nevertheless, in the proposed MLS algorithm, online SG parameters estimation is accomplished using PMU data without relying on rotor angle measurement that is difficult to be obtained in practise. Simulation results demonstrate the effectiveness of the proposed algorithm in SG parameters estimation for various disturbances and noisy measurements. Furthermore, the effect of mechanical torque signal unavailability on the proposed algorithm capability is studied, where the efficacy of this algorithm is proven.

2 April 2019 in Energies
Verified
Journal Article
Open access
PDF file
MAMoossa Khodadadi Arpanahi
Moossa Khodadadi Arpanahi
MKMeysam Kordi
Meysam Kordi
RTRoozbeh Torkzadeh
Roozbeh Torkzadeh
Hassan Haes AlhelouHassan Haes Alhelou
Hassan Haes Alhelou
PSPierluigi Siano
Pierluigi Siano
Intrinsic mode functions (IMFs) provide an intuitive representation of the oscillatory modes and are mainly calculated using Hilbert–Huang transform (HHT) methods. Those methods, however, suffer from the end effects, mode-mixing and Gibbs phenomena since they use an iterative procedure. This paper proposes an augmented Prony method for power system oscillation analysis using synchrophasor data obtained from a wide-area measurement system (WAMS). In the proposed method, in addition to the estimation of the modal information, IMFs are extracted using a new explicit mathematical formulation. Further, an indicator based on an energy and phase relationship of IMFs is proposed, which allows system operators to recognize the most effective generators/actuators on specific modes. The method is employed as an online oscillation-monitoring framework providing inputs for the so-called wide-area damping control (WADC) module. The efficacy of the proposed method is validated using three test cases, in which the IMFs calculation is simpler and more accurate if compared with other methods.

11 November 2022 in Electric Power Systems Research
Verified
Journal Article
Closed access
MAMoossa Khodadadi Arpanahi
Moossa Khodadadi Arpanahi
RTRoozbeh Torkzadeh
Roozbeh Torkzadeh
ASArash Safavizadeh
Arash Safavizadeh
AAAli Ashrafzadeh
Ali Ashrafzadeh
FEFariborz Eghtedarnia
Fariborz Eghtedarnia

1 June 2020
Verified
Conference Paper
Closed access
HCHarold R. Chamorro
Harold R. Chamorro
RTRoozbeh Torkzadeh
Roozbeh Torkzadeh
MEMojtaba Eliassi
Mojtaba Eliassi
PBPedro Betancourt-Paulino
Pedro Betancourt-Paulino
MRMichel Rezkalla
Michel Rezkalla
WMWilmar Martinez
Wilmar Martinez
The imminent transformation of the power grid with the large inclusion of renewable resources is bringing new challenges to face on. These challenges include an inertia diminution causing drastic changes in the frequency response. This paper analyses the impact of the gradual synthetic inertial control inclusion in the Nordic system as a possible remedial action to contribute in the primary frequency response. Additionally, it proposes slightly changes in the typical synthetic inertial controller to not only reduce the nadir but in the overshoot. Furthermore, the effect of proportional wind power curtailment in improvement of primary frequency response is assessed. Finally, several scenarios for the inertial controller and adjustments are tested in the Nordic 32 test system.