Rossella Svigelj

Dr. Rossella Svigelj

University of Udine, Italy
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 June 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Rossella SvigeljRossella Svigelj
Rossella Svigelj
NDNicolo Dossi
Nicolo Dossi
CGCristian Grazioli
Cristian Grazioli
Rosanna TonioloRosanna Toniolo
Rosanna Toniolo
Deep Eutectic Solvents (DESs) are a new class of solvents characterized by a remarkable decrease in melting point compared to those of the starting components. The eutectic mixtures can be simply prepared by mixing a Hydrogen Bond Acceptor (HBA) with a Hydrogen Bond Donor (HBD) at a temperature of about 80 °C. They have found applications in different research fields; for instance, they have been employed in organic synthesis, electrochemistry, and bio-catalysis, showing improved biodegradability and lower toxicity compared to other solvents. Herein, we review the use of DESs in biosensor development. We consider the emerging interest in different fields of this green class of solvents and the possibility of their use for the improvement of biosensor performance. We point out some promising examples of approaches for the assembly of biosensors exploiting their compelling characteristics. Furthermore, the extensive ability of DESs to solubilize a wide range of molecules provides the possibility to set up new devices, even for analytes that are usually insoluble and difficult to quantify.

17 March 2022 in Nanomaterials
Verified
Journal Article
Open access
PDF file
Rossella SvigeljRossella Svigelj
Rossella Svigelj
IZIvan Zuliani
Ivan Zuliani
CGCristian Grazioli
Cristian Grazioli
NDNicolo Dossi
Nicolo Dossi
Rosanna TonioloRosanna Toniolo
Rosanna Toniolo
Nanomaterials can be used to modify electrodes and improve the conductivity and the performance of electrochemical sensors. Among various nanomaterials, gold-based nanostructures have been used as an anchoring platform for the functionalization of biosensor surfaces. One of the main advantages of using gold for the modification of electrodes is its great affinity for thiol-containing molecules, such as proteins, forming a strong Au-S bond. In this work, we present an impedimetric biosensor based on gold nanoparticles and a truncated aptamer for the quantification of gluten in hydrolyzed matrices such as beer and soy sauce. A good relationship between the Rct values and PWG-Gliadin concentration was found in the range between 0.1–1 mg L−1 of gliadin (corresponding to 0.2–2 mg L−1 of gluten) with a limit of detection of 0.05 mg L−1 of gliadin (corresponding to 0.1 mg L−1 of gluten). The label-free assay was also successfully applied for the determination of real food samples.

6 October 2021 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Open access
PDF file
Rossella SvigeljRossella Svigelj
Rossella Svigelj
NDNicolo Dossi
Nicolo Dossi
CGCristian Grazioli
Cristian Grazioli
Rosanna TonioloRosanna Toniolo
Rosanna Toniolo
Paper has been widely employed as cheap material for the development of a great number of sensors such as pregnancy tests, strips to measure blood sugar, and COVID-19 rapid tests. The need for new low-cost analytical devices is growing, and consequently the use of these platforms will be extended to different assays, both for the final consumer and within laboratories. This work describes a paper-based electrochemical sensing platform that uses a paper disc conveniently modified with recognition molecules and a screen-printed carbon electrode (SPCE) to achieve the detection of gluten in a deep eutectic solvent (DES). This is the first method coupling a paper biosensor based on aptamers and antibodies with the DES ethaline. Ethaline proved to be an excellent extraction medium allowing the determination of very low gluten concentrations. The biosensor is appropriate for the determination of gluten with a limit of detection (LOD) of 0.2 mg L−1 of sample; it can detect gluten extracted in DES with a dynamic range between 0.2 and 20 mg L−1 and an intra-assay coefficient of 10.69%. This approach can be of great interest for highly gluten-sensitive people, who suffer from ingestion of gluten quantities well below the legal limit, which is 20 parts per million in foods labeled gluten-free and for which highly sensitive devices are essential. Graphical abstract

30 June 2017 in Food Analytical Methods
Verified
Journal Article
Closed access
PDF file
Rossella SvigeljRossella Svigelj
Rossella Svigelj
RBRenzo Bortolomeazzi
Renzo Bortolomeazzi
NDNicolò Dossi
Nicolò Dossi
Agnese GiacominoAgnese Giacomino
Agnese Giacomino
GBGino Bontempelli
Gino Bontempelli
Rosanna TonioloRosanna Toniolo
Rosanna Toniolo

29 October 2015 in Electroanalysis
Verified
Journal Article
Closed access
PDF file
Rosanna TonioloRosanna Toniolo
Rosanna Toniolo
NDNicolò Dossi
Nicolò Dossi
Rossella SvigeljRossella Svigelj
Rossella Svigelj
LPLaura Pigani
Laura Pigani
FTFabio Terzi
Fabio Terzi
GBGino Bontempelli
Gino Bontempelli

1 March 2017 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
RTRosanna Toniolo
Rosanna Toniolo
RBRenzo Bortolomeazzi
Renzo Bortolomeazzi
Rossella SvigeljRossella Svigelj
Rossella Svigelj
NDNicolò Dossi
Nicolò Dossi
ICInnocenzo G. Casella
Innocenzo G. Casella
SDSalvatore Daniele
Salvatore Daniele