Many stadiums will be built in China in the next few decades due to increasing public interest in physical exercise and the incentive policies issued by the government under its National Fitness Program. This paper investigates the energy saving and carbon reduction performance of timber stadiums in China in comparison with stadiums constructed using conventional building materials, based on both life cycle energy assessment (LCEA) and life cycle carbon assessment (LCCA). The authors select five representative cities in five climate zones in China as the simulation environment, simulate energy use in the operation phase of stadiums constructed from reinforced concrete (RC) and timber, and compare the RC and timber stadiums in terms of their life cycle energy consumption and carbon emissions. The LCEA results reveal that the energy saving potential afforded by timber stadiums is 11.05%, 12.14%, 8.15%, 4.61% and 4.62% lower than those of RC buildings in “severely cold,” “cold,” “hot summer, cold winter,” “hot summer, warm winter,” and “temperate” regions, respectively. The LCCA results demonstrate that the carbon emissions of timber stadiums are 15.85%, 15.86%, 18.88%, 19.22% and 22.47% lower than those of RC buildings for the regions above, respectively. This demonstrates that in China, timber stadiums have better energy conservation and carbon reduction potential than RC stadiums, based on life cycle assessment. Thus, policy makers are advised to encourage the promotion of timber stadiums in China to achieve the goal of sustainable energy development for public buildings.
Global warming is resulting in higher summer indoor temperatures in the severe cold region and cold region of China, and this is affecting thermal comfort. Local building design codes consider these regions as cool in summer, and do not consider the phenomenon of overheating or propose countermeasures. This paper studied the possibility of overheating in residential buildings in these areas. It suggested alleviating this phenomenon using external horizontal shading, and discussed how to integrate thermal comfort into the building design and save energy consumption. The IESVE software was used to simulate 18-storey residential buildings with natural ventilation in Yichun, Harbin, Shenyang, Dalian, and Beijing, and to calculate the change in indoor operative temperature. Horizontal shading was designed for case study building to attempt to alleviate the overheating phenomenon in summer. The results showed that the case study building in the five cities experienced different degrees of overheating. External horizontal shading was successful in reducing indoor overheating, especially in the severe cold B and C zones and the cold A and B zones. The relevant building codes should be modified to take this into account. Reasonable design of horizontal shading can effectively reduce energy consumption, particularly when compared with air-conditioned buildings.
Given the prediction of global warming, there is a growing concern about overheating in the severe cold and cold regions of China. In the past decades, indoor thermal comfort has been neglected in building practice, while efficiency-oriented improvements have been developed, such as increased insulation of building envelope. An extensive literature review shows contradictory conclusions about whether increased insulation can alleviate overheating. The aim of this research is to conduct simulations based on measured data to reveal the influence of insulation on overheating in dwellings in these regions of China. An unoccupied residential flat was monitored to determine the extent of overheating while eliminating the effects of other contributors, such as natural ventilation. Validated building performance simulations were carried out with altered insulation layer thickness in Integrated Environmental Solutions-Virtual Environment IESVE software to examine its influence on overheating during summertime in five representative cities. The results showed clear evidence of summer overheating in these regions. In Yichun, Harbin, Shenyang, Dalian and Beijing, walls with increased insulation were found to exacerbate overheating in the bedrooms without natural ventilation by 22.5%, 16.6%, 20.3%, 11.8% and 6.9%, respectively, compared to the uninsulated walls. This study provides useful information for building regulations on energy efficiency and thermal comfort.