Sahadev Shankarappa

Dr. Sahadev Shankarappa

Amrita Vishwa Vidyapeetham
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 January 2020 in Journal of The Royal Society Interface
Verified
Journal Article
Open access
PMPallavi Madhusudanan
Pallavi Madhusudanan
GRGayathri Raju
Gayathri Raju
SSSahadev Shankarappa
Sahadev Shankarappa
Neural tissue engineering (NTE) is a rapidly progressing field that promises to address several serious neurological conditions that are currently difficult to treat. Selecting the right scaffolding material to promote neural and non-neural cell differentiation as well as axonal growth is essential for the overall design strategy for NTE. Among the varieties of scaffolds, hydrogels have proved to be excellent candidates for culturing and differentiating cells of neural origin. Considering the intrinsic resistance of the nervous system against regeneration, hydrogels have been abundantly used in applications that involve the release of neurotrophic factors, antagonists of neural growth inhibitors and other neural growth-promoting agents. Recent developments in the field include the utilization of encapsulating hydrogels in neural cell therapy for providing localized trophic support and shielding neural cells from immune activity. In this review, we categorize and discuss the various hydrogel-based strategies that have been examined for neural-specific applications and also highlight their strengths and weaknesses. We also discuss future prospects and challenges ahead for the utilization of hydrogels in NTE.

13 January 2014 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
PDF file
BTBrian P. Timko
Brian P. Timko
Manuel ArrueboManuel Arruebo
Manuel Arruebo
SSSahadev Shankarappa
Sahadev Shankarappa
JMJ. Brian McAlvin
J. Brian McAlvin
OOObiajulu S. Okonkwo
Obiajulu S. Okonkwo
DKDaniel S. Kohane
Daniel S. Kohane
Significance: Devices that release a drug in response to a remote trigger would enable on-demand control of the timing and dose of drug released. They would allow the patient or physician to adjust therapy precisely to a target effect, thus improving treatment and reducing toxicity. We have developed implantable reservoirs that release a drug when irradiated with near-infrared laser light. The release rate was correlated to laser intensity, with negligible leakage between doses. Devices containing aspart, a fast-acting analog of insulin, were implanted in diabetic rats and were able to achieve glycemic control upon irradiation. Such devices can be loaded with a wide range of drugs to treat a variety of clinical indications.

1 August 2012 in Journal of Controlled Release
Verified
Journal Article
Open access
CWChristopher B. Weldon
Christopher B. Weldon
JTJonathan H. Tsui
Jonathan H. Tsui
SSSahadev Shankarappa
Sahadev Shankarappa
VNVy T. Nguyen
Vy T. Nguyen
MMMinglin Ma
Minglin Ma
DKDaniel S. Kohane
Daniel S. Kohane
We have developed a local anesthetic-eluting suture system which would combine the function and ubiquity of the suture for surgical repair with the controlled release properties of a biodegradable polymeric matrix. Drug-free and drug-loaded poly(lactic-co-glycolic acid) (PLGA) sutures were fabricated by electrospinning, with or without the local anesthetic bupivacaine. The tensile strength of the electrospun sutures decreased as drug content increased, but strains remained relatively similar across all groups. Sutures released their entire drug payload over the course of 12 days and maintained approximately 12% of their initial tensile strength after 14 days of incubation in vitro. In a rat skin wound model, local analgesia was achieved 1 day after surgery and lasted approximately 1 week in 90% of treated animals (n=10, p<0.05), and all wounds were able to heal normally without the need for further reinforcement. The sutures caused tissue reaction in vivo that was comparable to that seen with a commercially available suture composed of PLGA. Such sutures may enhance perioperative analgesia and mitigate the need for standard postoperative opioid analgesics.

11 March 2016 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
SPSmrithi Padmakumar
Smrithi Padmakumar
John JosephJohn Joseph
John Joseph
MNMadhuri Harsha Neppalli
Madhuri Harsha Neppalli
SMSumi Elizabeth Mathew
Sumi Elizabeth Mathew
SNShantikumar V Nair
Shantikumar V Nair
DMDeepthy Menon
Deepthy Menon

1 February 2018 in Journal of Dermatological Science
Verified
Journal Article
Closed access
GRGayathri Raju
Gayathri Raju
NKNeeraj Katiyar
Neeraj Katiyar
SVSajini Vadukumpully
Sajini Vadukumpully
SSSahadev Shankarappa
Sahadev Shankarappa

2 June 2011 in Journal of Neurochemistry
Verified
Journal Article
Closed access
PDF file
SSSahadev Shankarappa
Sahadev Shankarappa
EPErika Sofía Piedras-Renteria
Erika Sofía Piedras-Renteria
ESEvan Stubbs
Evan Stubbs