Christina Salchow-Hömmen

Dr. Christina Salchow-Hömmen

Charité-Universitätsmedizin Berlin
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 February 2022 in Frontiers in Human Neuroscience
Verified
Journal Article
Open access
CSChristina Salchow-Hömmen
Christina Salchow-Hömmen
MSMatej Skrobot
Matej Skrobot
MJMagdalena C. E. Jochner
Magdalena C. E. Jochner
TSThomas Schauer
Thomas Schauer
AKAndrea A. Kühn
Andrea A. Kühn
NWNikolaus Wenger
Nikolaus Wenger
The understanding of locomotion in neurological disorders requires technologies for quantitative gait analysis. Numerous modalities are available today to objectively capture spatiotemporal gait and postural control features. Nevertheless, many obstacles prevent the application of these technologies to their full potential in neurological research and especially clinical practice. These include the required expert knowledge, time for data collection, and missing standards for data analysis and reporting. Here, we provide a technological review of wearable and vision-based portable motion analysis tools that emerged in the last decade with recent applications in neurological disorders such as Parkinson's disease and Multiple Sclerosis. The goal is to enable the reader to understand the available technologies with their individual strengths and limitations in order to make an informed decision for own investigations and clinical applications. We foresee that ongoing developments toward user-friendly automated devices will allow for closed-loop applications, long-term monitoring, and telemedical consulting in real-life environments.

8 January 2019 in Sensors
Verified
Journal Article
Open access
PDF file
CSChristina Salchow-Hömmen
Christina Salchow-Hömmen
LCLeonie Callies
Leonie Callies
DLDaniel Laidig
Daniel Laidig
MVMarkus Valtin
Markus Valtin
TSThomas Schauer
Thomas Schauer
TSThomas Seel
Thomas Seel
Objective real-time assessment of hand motion is crucial in many clinical applications including technically-assisted physical rehabilitation of the upper extremity. We propose an inertial-sensor-based hand motion tracking system and a set of dual-quaternion-based methods for estimation of finger segment orientations and fingertip positions. The proposed system addresses the specific requirements of clinical applications in two ways: (1) In contrast to glove-based approaches, the proposed solution maintains the sense of touch. (2) In contrast to previous work, the proposed methods avoid the use of complex calibration procedures, which means that they are suitable for patients with severe motor impairment of the hand. To overcome the limited significance of validation in lab environments with homogeneous magnetic fields, we validate the proposed system using functional hand motions in the presence of severe magnetic disturbances as they appear in realistic clinical settings. We show that standard sensor fusion methods that rely on magnetometer readings may perform well in perfect laboratory environments but can lead to more than 15 cm root-mean-square error for the fingertip distances in realistic environments, while our advanced method yields root-mean-square errors below 2 cm for all performed motions.

10 June 2023 in ACM Transactions on Computer-Human Interaction
Verified
Journal Article
Open access
ASAdwait Sharma
Adwait Sharma
CSChristina Salchow-Hömmen
Christina Salchow-Hömmen
VMVimal Suresh Mollyn
Vimal Suresh Mollyn
ANAditya Shekhar Nittala
Aditya Shekhar Nittala
MHMichael A. Hedderich
Michael A. Hedderich
JSJürgen Steimle
Jürgen Steimle
Gestural interaction with freehands and while grasping an everyday object enables always-available input . To sense such gestures, minimal instrumentation of the user’s hand is desirable. However, the choice of an effective but minimal IMU layout remains challenging, due to the complexity of the multi-factorial space that comprises diverse finger gestures, objects, and grasps. We present SparseIMU , a rapid method for selecting minimal inertial sensor-based layouts for effective gesture recognition. Furthermore, we contribute a computational tool to guide designers with optimal sensor placement. Our approach builds on an extensive microgestures dataset that we collected with a dense network of 17 inertial measurement units (IMUs). We performed a series of analyses, including an evaluation of the entire combinatorial space for freehand and grasping microgestures (393 K layouts), and quantified the performance across different layout choices, revealing new gesture detection opportunities with IMUs. Finally, we demonstrate the versatility of our method with four scenarios.

18 August 2016 in Frontiers in Human Neuroscience
Verified
Journal Article
Open access
CSChristina Salchow-Hömmen
Christina Salchow-Hömmen
DSDaniel Strohmeier
Daniel Strohmeier
SKSascha Klee
Sascha Klee
DJDunja Jannek
Dunja Jannek
KSKarin Schiecke
Karin Schiecke
JHJens Haueisen
Jens Haueisen
A controversy exists on photic driving in the human visual cortex evoked by intermittent photic stimulation. Frequency entrainment and resonance phenomena are reported for frequencies higher than 12 Hz in some studies while missing in others. We hypothesized that this might be due to different experimental conditions, since both high and low intensity light stimulation were used. However, most studies do not report radiometric measurements, which makes it impossible to categorize the stimulation according to photopic, mesopic, and scotopic vision. Low intensity light stimulation might lead to scotopic vision, where rod perception dominates. In this study, we investigated photic driving for rod-dominated visual input under scotopic conditions. Twelve healthy volunteers were stimulated with low intensity light flashes at 20 stimulation frequencies, leading to rod activation only. The frequencies were multiples of the individual alpha frequency (α) of each volunteer in the range from 0.40–2.30*α. 306-channel whole head magnetoencephalography recordings were analyzed in time, frequency, and spatiotemporal domains with the Topographic Matching Pursuit algorithm. We found resonance phenomena and frequency entrainment for stimulations at or close to the individual alpha frequency (0.90–1.10*α) and half of the alpha frequency (0.40–0.55*α). No signs of resonance and frequency entrainment phenomena were revealed around 2.00*α. Instead, on-responses at the beginning and off-responses at the end of each stimulation train were observed for the first time in a photic driving experiment at frequencies of 1.30–2.30*α, indicating that the flicker fusion threshold was reached. All results, the resonance and entrainment as well as the fusion effects, provide evidence for rod-dominated photic driving in the visual cortex.

1 March 2017 in Current Directions in Biomedical Engineering
Verified
Journal Article
Open access
PDF file
MVMarkus Valtin
Markus Valtin
CSChristina Salchow-Hömmen
Christina Salchow-Hömmen
TSThomas Seel
Thomas Seel
DLDaniel Laidig
Daniel Laidig
TSThomas Schauer
Thomas Schauer
The assessment of hand posture and kinematics is increasingly important in various fields. This includes the rehabilitation of stroke survivors with restricted hand function. This paper presents a modular, ambulatory measurement system for the assement of the remaining hand function and for closed-loop controlled therapy. The device is based on inertial sensors and utilizes up to five interchangeable sensor strips to achieve modularity and to simplify the sensor attachment. We introduce the modular hardware design and describe algorithms used to calculate the joint angles. Measurements with two experimental setups demonstrate the feasibility and the potential of such a tracking device.

29 December 2018 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
CSChristina Salchow-Hömmen
Christina Salchow-Hömmen
NJNatalie Jankowski
Natalie Jankowski
MVMarkus Valtin
Markus Valtin
LSLaura Schönijahn
Laura Schönijahn
SBSebastian Böttcher
Sebastian Böttcher
TSThomas Schauer
Thomas Schauer
Surface electrode arrays have become popular in the application of functional electrical stimulation (FES) on the forearm. Arrays consist of multiple, small elements, which can be activated separately or in groups, forming virtual electrodes (VEs). As technology progress yields rising numbers of possible elements, an effective search strategy for suitable VEs in electrode arrays is of increasing importance. Current methods can be time-consuming, lack user integration, and miss an evaluation regarding clinical acceptance and practicability. Two array identification procedures with different levels of user integration—a semi-automatic and a fully automatic approach—are evaluated. The semi-automatic method allows health professionals to continuously modify VEs via a touchscreen while the stimulation intensities are automatically controlled to maintain sufficient wrist extension. The automatic approach evaluates stimulation responses of various VEs for different intensities using a cost function and joint-angles recordings. Both procedures are compared in a clinical setup with five sub-acute stroke patients with moderate hand disabilities. The task was to find suitable VEs in two arrays with 59 elements in total to generate hand opening and closing for a grasp-and-release task. Practicability and acceptance by patients and health professionals were investigated using questionnaires and interviews. Both identification methods yield suitable VEs for hand opening and closing in patients who could tolerate the stimulation. However, the resulting VEs differed for both approaches. The average time for a complete search was 25% faster for the semi-automatic approach (semi-automatic: 7.3min, automatic: 10.5min). User acceptance was high for both methods, while no clear preference could be identified. The semi-automatic approach should be preferred as the search strategy in arrays on the forearm. The observed faster search duration will further reduce when applying the system repeatedly on a patient as only small position adjustments for VEs are required. However, the setup time will significantly increase for generation of various grasp types and adaptation to different arm postures. We recommend different levels of user integration in FES systems such that the search strategy can be chosen based on the users’ preferences and application scenario.