Sanober Khattak

Dr. Sanober Khattak

De Montfort University
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 March 2021 in Buildings
Verified
Journal Article
Open access
PDF file
JSJamal Saif
Jamal Saif
Andrew John WrightAndrew John Wright
Andrew John Wright
SKSanober Khattak
Sanober Khattak
Kasim ElfadliKasim Elfadli
Kasim Elfadli
In hot arid climates, air conditioning in the summer dominates energy use in buildings. In Kuwait, energy demand in buildings is dominated by cooling, which also determines the national peak electricity demand. Schools contribute significantly to cooling demand, but also suffer from poor ventilation. This paper presents analysis of a ventilation and cooling system for school classrooms using a wind catcher for natural ventilation and evaporative cooling. A school classroom in Kuwait with single-sided ventilation was modelled using the DesignBuilder V5.4/EnergyPlus V9.1 software and calibrated using field data. The model was used to analyse the performance of a wind catcher, with and without evaporative cooling, in terms of energy use, thermal comfort and indoor air quality. Compared to the baseline of using air-conditioning only, a wind catcher with evaporative cooling was found to reduce energy use by 52% during the summer months while increasing the comfortable hours from 76% to 100% without any supplementary air conditioning. While the time below the ASHRAE CO2 limit also improved from 11% to 24% with the wind catcher, the indoor air quality was still poor. These improvements came at the cost of a 14% increase in relative humidity. As the wind catcher solution appears to have potential with further development; several avenues for further research are proposed.

1 November 2018 in Energy Reports
Verified
Journal Article
Open access
SKSanober Khattak
Sanober Khattak
RGRichard Greenough
Richard Greenough
VSVishal Sardeshpande
Vishal Sardeshpande
NBNeil Brown
Neil Brown

1 May 2016 in Journal of Cleaner Production
Verified
Journal Article
Open access
SKSanober Khattak
Sanober Khattak
RGRichard Greenough
Richard Greenough
IKIvan Korolija
Ivan Korolija
NBNeil Brown
Neil Brown
Resource accounting is widely practiced to identify opportunities for improving the sustainability of industrial systems. This paper presents a conceptual method for resource accounting in factories that is based on the fundamentals of thermodynamics. The approach uses exergy analysis and treats the factory as an integrated energy system comprising a building, its technical building services and manufacturing processes. The method is illustrated with a case study of an automotive cylinder head manufacturing line in which the resource efficiency of this part of the factory is analysed for different energy system options relating to heating ventilation and air conditioning. Firstly, the baseline is compared with the use of a solar photovoltaic array to generate electricity, and then a heat recovery unit is considered. Finally, both of these options are used together, and here it was found that the non-renewable exergy supply and exergy destruction are reduced by 51.6% and 49.2% respectively. Also, it was found that a conventional energy analysis would overestimate the resource savings from reducing the hot water supplied to the heating system, since energy analysis cannot account for energy quality. Since exergy analysis accounts for both energy quality and quantity it produces a different result. The scientific value of this paper is that it presents an exergy-based approach for factory resource accounting, which is illustrated through application to a real factory. The exergy-based approach is shown to be a valuable complement to energy analysis, which could lead to a more resource efficient system design than one based on energy analysis alone

20 April 2018 in Energies
Verified
Journal Article
Open access
PDF file
SKSanober Khattak
Sanober Khattak
MOMichael Oates
Michael Oates
RGRichard Greenough
Richard Greenough
Exergy analysis has widely been used to assess resource consumption, and to identify opportunities for improvement within manufacturing. The main advantages of this method are its ability to account for energy quality and consumption. However, its application in industrial practice is limited, which may be due to the lack of its consistent application in practice. Current energy management standard, that facilitate consistent application of procedures do not consider the quality aspects of energy flows. An exergy based energy management standards is proposed in this paper that would take into account energy quality aspects, while facilitating the consistent application of exergy analysis in industrial practice. Building on ISO50001, this paper presents guidelines for implementing energy and resource management in factories, incorporating the concepts of exergy and holistic factory simulation, as illustrated through a manufacturing case study. From the factory level analysis, a chilling process was identified to have significant improvement potential. A dry fan cooler, using ambient air was proposed for the improved efficiency of the chillers. Energy based metrics portrayed a system that operated at high efficiency, however exergy analysis indicated much room for further improvement, therefore impacting decision making for technology selection. The contribution of this paper is in presenting a set of prescriptive guidelines that could possibly be further developed into a new energy management standard that would utilize the advantages of exergy analysis towards improved energy and resource management in manufacturing.

20 January 2023 in Journal of Building Engineering
Verified
Journal Article
Open access
WCWoong June Chung
Woong June Chung
SKSanober Khattak
Sanober Khattak
FCFrancesca Cecinati
Francesca Cecinati
SJSu-Gwang Jeong
Su-Gwang Jeong
TKTristan Kershaw
Tristan Kershaw
Sukumar NatarajanSukumar Natarajan
Sukumar Natarajan

5 August 2025 in Sustainability
Verified
Journal Article
Open access
PDF file
AMAbdulrahman Haruna Muhammad
Abdulrahman Haruna Muhammad
Ahmad TakiAhmad Taki
Ahmad Taki
SKSanober Khattak
Sanober Khattak
Green buildings are recognised for their potential to reduce energy consumption, minimise environmental impact, and improve occupants’ well-being, benefits that are especially critical in rapidly urbanising regions. However, questions remain about whether these buildings fully meet occupant comfort expectations while delivering energy efficiency. This is particularly relevant in Africa, where climate conditions and energy infrastructure challenges make sustainable building operation essential. Although interest in sustainable construction has increased, limited research has examined the real-world performance of green buildings in Africa. This study helps address that gap by evaluating indoor thermal comfort in a green-certified office building and two conventional office buildings in Abuja, Nigeria, through post-occupancy evaluation (POE). The Predicted Mean Vote (PMV) and Thermal Sensation Vote (TSV) were used to assess comfort, revealing discrepancies between predicted and actual occupant responses. In the green building, PMV indicated near-neutral conditions (0.28), yet occupants reported a slightly cool sensation (TSV: −1.1). Neutral temperature analysis showed that the TSV-based neutral temperature (26.5 °C) was 2.2 °C higher than the operative temperature (24.3 °C), suggesting overcooling. These findings highlight the importance of incorporating occupant feedback into HVAC control. Aligning cooling setpoints with comfort preferences could improve satisfaction and reduce unnecessary cooling, promoting energy-efficient building operation.