This paper presents hybrid sensorless speed tracking by an indirect field-oriented control (IFOC) for an induction motor (IM). The sensorless model is based on an improved virtual estimation topology model to predict the virtual speed and flux of the IM using stator current components. The hybrid sensorless model, defined as a modification of voltage with a rotor flux-oriented current model, was also implemented with proportional-integral (PI) control for comparison with the conventional voltage model (CVM). The suggested adaptive mechanism for PI control in the hybrid estimator was able to compensate for the back-EMF error from the rotor flux-oriented current model into the voltage model and change the air gap flux of the IM. An accurate rotor flux position was estimated and used to estimate the speed with low speed error. This IFOC model, with various speed change references, was tested in a simulation environment by using the MATLAB/Simulink program. The proposed hybrid estimator was tested in two different EV operations, which were reverse and forward operations. The effectiveness of the proposed estimator was analyzed for its transient and steady-state performances based on settling time, recovery time and the overshoot and speed error percentages. All the results were in good agreement in terms of the stability of the speed and current controller with minimum speed error obtained, where the average errors were 0.08% and 0.16% for high speed and lower speed, respectively.
30 April 2020 in International Review on Modelling and Simulations (IREMOS)
This project describes the development of a Variable Voltage Variable Frequency (VVVF) system that control the speed of Induction Motor (IM). The target value of VVVF is implemented with the Lookup Table and with the Proportional Integral (PI) for speed control. The LookUp Table give the speed input to be independent control. Both simulation and hardware implementation have been conducted in order to observed the integration between them for generating a suitbale PWM signal to inverter. The results, show, this integration is able to control the IM speed based on the desired target value. Several tests speed at the IM during the reference are 1300rpm and 1500rpm where the real outputs are 1297rpm and 1499rpm. At the end it can be concluded that, the VVVF when combined with the lookup table has created an ecosystem for simple speed control that can be learn and understand by the student.
Control techniques for neural-network-based charging stations (CSs) are attracting attention worldwide. This popularity is due to the emergent need for alternative intelligent and adaptive control solutions for attaining a CS with stabilized power transfer and voltage control at the point of common coupling. This paper demonstrates novel neural-network-based improved virtual synchronous motor (NN-i-VSM) control through the mechanism of the charging voltage feedback in conjunction with a trained neural network model to adaptively produce field excitation (MN) that mimics a virtual flux model. The MN adaptively generates an electromotive force based on the trained NN output to control the rectifying converter response of the CS for power quality enhancement during multiple-CS operation. Simulation results in the scenario of multiple CSs at 750 kW (5 × 150 kW) with varying capacities showed significant improvement in voltage variable tracking capacity of up to 500 V as well as power response overshot reduction and grid voltage response tracking improvement compared with an i-VSM-based CS model. A comprehensive CS efficiency assessment and plant stability analysis, including Bode plot evaluation, further confirmed the superior dynamic response performance and robustness of the NN-i-VSM model over the i-VSM model. The proposed model offers scalable applicability in smart mobility and wireless CS integration, signifying a new control advancement for future generations of multiple-grid-friendly charging infrastructure for penetration of batteries at varying capacities.
9 February 2026 in Journal of Electrical Engineering & Technology
The low inertia system and Low-Frequency Oscillation (LFO) oscillation between 0.1-2 Hz will affect the power system stability. The occurrence of short circuit faults within milliseconds ultimately shifts the load supply from the main source to other generating units, leading to the loss of generator synchronization. By reducing LFOs during stress conditions, the power transfer between loads and generation becomes more stable and controlled. The most alarming issue is the enhancement of power transfer capability between two or more interconnected areas that are being addressed to be solved in this paper. To ensure optimized power flow, centralized control, damp LFOs, and robust performance during critical fault are required. An advanced third generation control for Smart Grid (SG) utilizing the Flexible AC Transmission System (FACTS), in particular Generalized Unified Power Flow Control (GUPFC), has been proposed with hybrid control in this paper. The objective is to create the importance of an online supplementary centralized controller to damp LFOs and to improve the transfer of power between loads to another generation source and the effect of the system due to weak inertia that causes asynchronization. The proposed supplementary controller is the Hybrid Adaptive Fuzzy Logic Neural Network Controller (HAFLNNC), which mitigates the system oscillation. It increases dynamic performance, reduces fluctuation across the DC capacitor, and maintains the bus voltage within a short period of cycle, which is evidenced in the results. Furthermore, the test system has been modelled in a two-area system with synchronous and asynchronous generators, Renewable Energy Resources (RES) as wind farms, grid to vehicles, PV farms, and residential load is considered. Finally, utilizing an SG environment, the performance of symmetrical three-phase to grid faults is critically analyzed in MATLAB/Simulink. At the end the overshoot and setting time improved by about 80% by using the suggested controller where it was indicated that the suggested controller managed to maintain the LFO to avoid generators shutdown.