MUBASHIR HAYAT KHAN

Dr. MUBASHIR HAYAT KHAN

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 October 2020 in Engineering, Technology & Applied Science Research
Verified
Journal Article
Open access
PDF file
EPE. Pathan
E. Pathan
ABA. Abu Bakar
A. Abu Bakar
SZS. A. Zulkifi
S. A. Zulkifi
MKMUBASHIR HAYAT KHAN
MUBASHIR HAYAT KHAN
HAH. Arshad
H. Arshad
MAMohammad Abdullah Al Asad
Mohammad Abdullah Al Asad
This paper presents a robust H∞ control technique for an islanded microgrid in the presence of sudden changes in load conditions. The proposed microgrid scheme consists of a parallel connected inverter with distributed generations. When the load is suddenly changed the frequency deviates from its nominal value. The objective is to design a robust frequency droop controller in order to achieve the frequency at nominal values without using any secondary controller and communication systems while improving power sharing accuracy. Small signal modeling of the power system is designed for the formulation of the problem and the H∞ optimal linear matrix inequality technique is applied in order to achieve the objectives. The proposed controller has been tested with the MATLAB/ SimPowerSytem toolbox.

8 January 2024 in Sustainability
Verified
Journal Article
Open access
PDF file
MKMUBASHIR HAYAT KHAN
MUBASHIR HAYAT KHAN
SZShamsul Aizam Zulkifli
Shamsul Aizam Zulkifli
Nedim TutkunNedim Tutkun
Nedim Tutkun
ABAlessandro Burgio
Alessandro Burgio
More and more distributed generations (DGs), such as wind, PV or battery bank sources, are connected to electric systems or customer loads. However, the locations of these DGs are based on the highest energy that can be potentially harvested for electric power generation. Therefore, these locations create different line impedances based on the distance from the DGs to the loads or the point of common coupling (PCC). This paper presents an adaptive virtual impedance (AVI) in the predictive control scheme in order to ensure power sharing accuracy and voltage stability at the PCC in a microgrid network. The reference voltage from mismatched feeder impedances was modified by utilizing the suggested AVI-based predictive control for creating equal power sharing between the DGs in order to avoid overburdening any individual DG with low-rated power. The AVI strategy used droop control as the input control for generating equal power sharing, while the AVI output was used as the reference voltage for the finite control set–model predictive control (FCS-MPC) for creating a minimum voltage error deviation for the cost function (CF) for the inverter’s vector switching pattern in order to improve voltage stability at the PCC. The proposed AVI-based controller was tested using two DG inverter circuits in a decentralized control mode with different values of line impedance and rated power. The performance of the suggested controller was compared via MATLAB/Simulink with that of a controller based on static virtual impedance (SVI) in terms of efficiency of power sharing and voltage stability at the PCC. From the results, it was found that (1) the voltage transient magnitude for the AVI-based controller was reduced within less than 0.02 s, and the voltage at the PCC was maintained with about 0.9% error which is the least as compared with those for the SVI-based controller and (2) equal power sharing between the DGs increased during the change in the load demand when using the AVI-based controller as compared with using the SVI-based controller. The proposed controller was capable of giving more accurate power sharing between the DGs, as well as maintaining the voltage at the PCC, which makes it suitable for the power generation of consumer loads based on DG locations for future energy communities.

30 May 2024 in Electronics
Verified
Journal Article
Open access
PDF file
MKMUBASHIR HAYAT KHAN
MUBASHIR HAYAT KHAN
SZShamsul Aizam Zulkifli
Shamsul Aizam Zulkifli
Nedim TutkunNedim Tutkun
Nedim Tutkun
Ismail EkmekciIsmail Ekmekci
Ismail Ekmekci
ABAlessandro Burgio
Alessandro Burgio
In islanded operation, precise power sharing is an immensely critical challenge when there are different line impedance values among the different-rated inverters connected to the same electrical network. Issues in power sharing and voltage compensation at the point of common coupling, as well as the reverse circulating current between inverters, are problems in existing control strategies for parallel-connected inverters if mismatched line impedances are not addressed. Therefore, this study aims to develop an improved decentralized controller for good power sharing with voltage compensation using the predictive control scheme and circulating current minimization between the inverters’ current flow. The controller was developed based on adaptive virtual impedance (AVI) control, combined with finite control set–model predictive control (FCS-MPC). The AVI was used for the generation of reference voltage, which responded to the parameters from the virtual impedance loop control to be the input to the FCS-MPC for a faster tracking response and to have minimum tracking error for better pulse-width modulation generation in the space-vector form. As a result, the circulating current was maintained at below 5% and the inverters were able to share an equal power based on the load required. At the end, the performance of the AVI-based control scheme was compared with those of the conventional and static-virtual-impedance-based methods, which have also been tested in simulation using MATLAB/Simulink software 2021a version. The comparison results show that the AVI FCS MPC give 5% error compared to SVI at 10% and conventional PI at 20%, in which AVI is able to minimize the circulating current when mismatch impedance is applied to the DGs.

8 May 2025 in Sustainability
Verified
Journal Article
Open access
PDF file
MKMUBASHIR HAYAT KHAN
MUBASHIR HAYAT KHAN
SZShamsul Aizam Zulkifli
Shamsul Aizam Zulkifli
Nedim TutkunNedim Tutkun
Nedim Tutkun
MŞMehmet Şimşir
Mehmet Şimşir
Parallel-connected inverters play a crucial role in the grid interface of distributed generation. The world is now moving towards sustainability, while shifting from traditional power systems to renewable energies. With the emergence of microgrids as an alternative for an uninterruptable power supply, there are significant challenges in terms of control strategies. Ensuring stability and reliability in electrical systems amidst the integration of diverse energy sources with varying power ratings into a distribution network presents the need for advanced control techniques. These techniques must effectively maintain power system quality, stability, and reliability when operating in microgrids with parallel-connected inverters. Achieving accurate power sharing under different operating conditions, compensating for voltage and frequency deviations, and maintaining a well-controlled microgrid system are essential objectives. This paper focuses on the categorization of droop-based control with multi-loop insertion approaches. Additionally, it provides a comprehensive analysis of inverter-based microgrid control techniques, emphasizing power-sharing accuracy in various conditions, and presents a detailed comparison of different control strategies.

9 February 2026 in Journal of Electrical Engineering & Technology
Verified
Journal Article
Open access
PDF file
NZNadia Zeb
Nadia Zeb
SZShamsul Aizam Zulkifli
Shamsul Aizam Zulkifli
MSMuhamad Syazmie Sepeeh
Muhamad Syazmie Sepeeh
MKMUBASHIR HAYAT KHAN
MUBASHIR HAYAT KHAN
The low inertia system and Low-Frequency Oscillation (LFO) oscillation between 0.1-2 Hz will affect the power system stability. The occurrence of short circuit faults within milliseconds ultimately shifts the load supply from the main source to other generating units, leading to the loss of generator synchronization. By reducing LFOs during stress conditions, the power transfer between loads and generation becomes more stable and controlled. The most alarming issue is the enhancement of power transfer capability between two or more interconnected areas that are being addressed to be solved in this paper. To ensure optimized power flow, centralized control, damp LFOs, and robust performance during critical fault are required. An advanced third generation control for Smart Grid (SG) utilizing the Flexible AC Transmission System (FACTS), in particular Generalized Unified Power Flow Control (GUPFC), has been proposed with hybrid control in this paper. The objective is to create the importance of an online supplementary centralized controller to damp LFOs and to improve the transfer of power between loads to another generation source and the effect of the system due to weak inertia that causes asynchronization. The proposed supplementary controller is the Hybrid Adaptive Fuzzy Logic Neural Network Controller (HAFLNNC), which mitigates the system oscillation. It increases dynamic performance, reduces fluctuation across the DC capacitor, and maintains the bus voltage within a short period of cycle, which is evidenced in the results. Furthermore, the test system has been modelled in a two-area system with synchronous and asynchronous generators, Renewable Energy Resources (RES) as wind farms, grid to vehicles, PV farms, and residential load is considered. Finally, utilizing an SG environment, the performance of symmetrical three-phase to grid faults is critically analyzed in MATLAB/Simulink. At the end the overshoot and setting time improved by about 80% by using the suggested controller where it was indicated that the suggested controller managed to maintain the LFO to avoid generators shutdown.

6 February 2021 in Engineering, Technology & Applied Science Research
Verified
Journal Article
Open access
PDF file
MSM. A. Shaikh
M. A. Shaikh
EPE. Pathan
E. Pathan
MRM. I. Rabani
M. I. Rabani
SGS. B. Goli
S. B. Goli
AQA. A. Qureshi
A. A. Qureshi
MKMUBASHIR HAYAT KHAN
MUBASHIR HAYAT KHAN
After large-scale photovoltaic (PV) and wind power integration with the national grid, the island grid detection is a crucial technique that identifies when a grid should be considered as dead. This logic is built in an IEC61850 grid controller which mainly depends on the bus bar scheme and fault type. It becomes more complex when the ½ circuit breaker scheme is utilized. The lack of communication redundancy causes island mal-operation due to the substation's DC supply failure. In order to avoid such mal-operation discrepancies, this paper investigates the conventional islanding detection method. Then, an advanced IEC61850 grid controller 2oo3 architecture is proposed for islanding detection, based on SAS redundant communication which improves reliability. However, even if there is an interface communication failure, the power plant control center can still detect the islanding through the proposed IEC61850 grid controller and SCADA IEC60870-5-101/104 gateways integration. This method has the tendency of full supervision of the entire grid and perfect logical judgment by plant operation staff. This feasible and the proposed redundant communication architecture can play a decisive role for power system network stability in order to avoid system blackout.