Progressive freeze concentration (PFC) is a process where only a large single ice crystal is formed in the system and grown on the cooling surface so that the separation between the ice crystal and the mother solution is very easy. This makes the system very simple and leads to a lower cost. The conventional setup of PFC produces ice with high purity but lower productivity than suspension freeze concentration (SFC). The volume of ice produced is also usually low. Hence, continued areas of the development for PFC system include the quest for improved productivity and better efficiency. Different kinds of design have been investigated, which are easy to operate and cost-effective besides the ability to obtain high quality of product and better efficiency of the system. The PFC system is recognized as a good alternative if high-quality products can be produced with higher productivity. In this article, previous researches on PFC designs were reviewed for the purpose of providing an understanding on methods of designing a PFC system and also to provide references for future application of PFC.
4 August 2015 in Chemical Engineering Communications
Progressive cryoconcentration (PC) is gaining acceptance in solution concentration process as it could provide an easy separation and ice purification with relatively low energy. In fact, the advantages of PC process as compared to the other concentration methods have led the growth of related studies that aim to provide the best system or condition for the separation process involved. Apart from the provision of appropriate equipment, the PC process should also be conducted at its optimum conditions of operating parameters involved, which could give the highest separation efficiency. Hence, relationship between the parameters, which covers both manipulated and determinant parameters should be studied first. This review summarizes the previous conducted studies on the effect of various operating parameters on the PC performance, which includes effect of coolant temperature, solution flowrate, initial solution concentration, freezing time, ice crystal front growth rate, and stirring rate.
1 December 2015 in Chemical Engineering Research and Design
Microalgae-based products have gained growing interest leading to an increase in large-scale cultivation. However, the high energy associated with microalgae harvesting becomes one of the bottlenecks. This study evaluated an energy-efficient microalga harvesting via ultra-low-pressure membrane (ULPM) filtration (<20 kPa) in combination with aeration. ULPM offered various benefits especially in terms of reducing the energy consumption due to it operated under low transmembrane pressure (TMP). High TMP often associated with high pumping energy hence would increase the amount of energy consumed. In addition, membrane with high TMP would severely affect by membrane compaction. Results showed that membrane compaction leads to up to 66 % clean water permeability loss when increasing the TMP from 2.5 to 19 kPa. The Chlorella vulgaris broth permeabilities decreased from 1660 and 1250 to 296 and 251 L/m2hrbar for corresponding TMPs for system with and without aeration, respectively. However, it was found that membrane fouling was more vulnerable at low TMP due to poor foulant scouring from a low crossflow velocity in which up to 56 % of permeability losses were observed. Membrane fouling is the biggest drawback of membrane system as it would reduce the membrane performance. In this study, aeration was introduced as membrane fouling control to scour-off the foulant from membrane surface and pores. In terms of energy consumption, it was observed that the specific energy consumption for the ULPM were very low of up to 4.4 × 10−3 kWh/m3. Overall, combination of low TMP with aeration offers lowest energy input.