shao enze

Dr. shao enze

Ningbo University, Ningbo, Zhejiang, China
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 June 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
shao enzeshao enze
shao enze
ZLZhenghui Lu
Zhenghui Lu
Xuanzhen CenXuanzhen Cen
Xuanzhen Cen
ZZZhiyi Zheng
Zhiyi Zheng
DSDong Sun
Dong Sun
Yaodong GuYaodong Gu
Yaodong Gu
The aim of this study was to assess the stiffness of each lower limb joint in healthy persons walking at varying speeds when fatigued. The study included 24 subjects (all male; age: 28.16 ± 7.10 years; height: 1.75 ± 0.04 m; weight: 70.62 ± 4.70 kg). A Vicon three-dimensional analysis system and a force plate were used to collect lower extremity kinematic and kinetic data from the participants before and after walking training under various walking situations. Least-squares linear regression equations were utilized to evaluate joint stiffness during single-leg support. Three velocities significantly affected the stiffness of the knee and hip joint (p < 0.001), with a positive correlation. However, ankle joint stiffness was significantly lower only at maximum speed (p < 0.001). Hip stiffness was significantly higher after walking training than that before training (p < 0.001). In contrast, knee stiffness after training was significantly lower than pre-training stiffness in the same walking condition (p < 0.001). Ankle stiffness differed only at maximum speed, and it was significantly higher than pre-training stiffness (p < 0.001). Walking fatigue appeared to change the mechanical properties of the joint. Remarkably, at the maximum walking velocity in exhaustion, when the load on the hip joint was significantly increased, the knee joint’s stiffness decreased, possibly leading to joint instability that results in exercise injury.

23 August 2022 in Bioengineering
Verified
Journal Article
Open access
PDF file
shao enzeshao enze
shao enze
Qichang MeiQichang Mei
Qichang Mei
JYJingyi Ye
Jingyi Ye
Ukadike UgbolueUkadike Ugbolue
Ukadike Ugbolue
CCChaoyi Chen
Chaoyi Chen
Yaodong GuYaodong Gu
Yaodong Gu
There are still few portable methods for monitoring lower limb joint coordination during the cutting movements (CM). This study aims to obtain the relevant motion biomechanical parameters of the lower limb joints at 90°, 135°, and 180° CM by collecting IMU data of the human lower limbs, and utilizing the Long Short-Term Memory (LSTM) deep neural-network framework to predict the coordination variability of selected lower extremity couplings at the three CM directions. There was a significant (p < 0.001) difference between the three couplings during the swing, especially at 90° vs the other directions. At 135° and 180°, t13-he coordination variability of couplings was significantly greater than at 90° (p < 0.001). It is important to note that the coordination variability of Hip rotation/Knee flexion-extension was significantly higher at 90° than at 180° (p < 0.001). By the LSTM, the CM coordination variability for 90° (CMC = 0.99063, RMSE = 0.02358), 135° (CMC = 0.99018, RMSE = 0.02465) and 180° (CMC = 0.99485, RMSE = 0.01771) were accurately predicted. The predictive model could be used as a reliable tool for predicting the coordination variability of different CM directions in patients or athletes and real-world open scenarios using inertial sensors.

9 July 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JYJingyi Ye
Jingyi Ye
LGlidong gao
lidong gao
shao enzeshao enze
shao enze
BKBálint Kovács
Bálint Kovács
JLJiao Li
Jiao Li
Yaodong GuYaodong Gu
Yaodong Gu
This study’s aim was to examine the effect of non-Newtonian fluid (NN) shoe and ethylene vinyl acetate (EVA) shoe on human lower limb biomechanics and muscle activation during running in hot temperatures. Thirty-five men utilizing a rearfoot strike ran 5 km at a self-selected tempo at an average summer temperature of 41.7 ± 1.0 °C and relative humidity of 80.7 ± 3.5%. The kinematics, kinetics, and muscle activation of the right leg were monitored from landing until the pedal was off the ground. A two-way repeated-measures ANOVA was conducted to investigate the main effects of the shoe condition, temperature, and interaction effect. Wearing NN at high temperature resulted in increased hip range of motion (ROM) (p = 0.001). The knee torque increased significantly when wearing EVA and NN shoes after the temperature increased (p = 0.006). When wearing EVA and NN, the ground reaction force (GRF) and loading rate (LR) increased significantly after the temperature increased (p = 0.001; p = 0.009). When wearing NN after running for 5 km at a high temperature, the displacement range of center of pressure (COP) was significantly reduced (p < 0.001), while the EVA was significantly increased (p < 0.001). Neither pair of shoes substantially altered muscle activity. After excluding the factor of fatigue, the increase in temperature not only changed the properties of the material inside the shoe, but also changed the parameters of the biomechanics of the human lower limbs. After the temperature increases, the shoes made of non-Newtonian fluid materials can quickly stabilize under the condition of increased shear stress and reduce the displacement of the human body. Thus, it indicated that non-Newtonian fluid shoes may lower the risk of injury when running in extremely hot conditions.

2 June 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
shao enzeshao enze
shao enze
Qichang MeiQichang Mei
Qichang Mei
TYTongjun Ye
Tongjun Ye
BKBálint Kovács
Bálint Kovács
JBJulien Baker
Julien Baker
Yaodong GuYaodong Gu
Yaodong Gu
Interval running methodologies simulate competition and training conditions, with the aim of enhancing an athletes’ ability to cope with constant deceleration, acceleration, and sudden changes in direction, as associated athletic and performance challenges. Fifteen male athletes were recruited in this study, in which the anterior cruciate ligament was modeled as a nonlinear elastic passive soft tissue in OpenSim 4.2. Participants completed 5 km interval running training on a treadmill. Before and after the interval running, kinematics, kinetics, and electromyography activity of the lower leg during the cutting maneuvers were collected simultaneously. After running training, the anterior cruciate ligament strain demonstrated a decreasing trend when performing unexpected cutting maneuvers. Principal component analysis showed significant differences in knee moments during abduction-adduction; knee angles in flexion-extension, external-internal rotation, and abduction-adduction, as well as knee contact forces in the sagittal and coronal planes. The findings of the study highlight that athletes generate greater adduction moment at the onset of the cut, followed by greater abduction moment towards the end of the cut, which may have a substantial impact on the anterior cruciate ligament loading. Furthermore, athletes need to be mindful of changes in coronal plane contact forces.

28 April 2026 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
shao enzeshao enze
shao enze
JZJiongxiang Zhao
Jiongxiang Zhao
WLWenlong Li
Wenlong Li
JBJulien S. Baker
Julien S. Baker
TGTibor J. Goda
Tibor J. Goda
Yaodong GuYaodong Gu
Yaodong Gu
Most fatigue-detection approaches for biomechanics rely on computationally intensive black-box models or apply thresholding without correcting for serial dependence, risking inflated false alarms when signals are autocorrelated. This study proposes an autoregressive integrated moving average with statistical process control (ARIMA–SPC) framework that models temporal dependence and identifies fatigue-related biomechanical anomalies from time-normalized ground reaction force and tibial inertial measurement units waveforms. In 32 participants performing repeated 90° lateral cutting maneuver trials before and after a 5-km variable-speed fatigue protocol. This is evident from their autocorrelation function plots, which oscillate and decay exponentially, forming a characteristic “tail-off” pattern. The most compelling finding is that the lag value of the coronal plane with ground reaction force is markedly greater than those of the other two planes (p<0.05). Relative to the long short-term memory model, the ARIMA–SPC model was easier to interpret and delivered stronger anomaly-detection performance, particularly in sensitivity (recall 0.88 vs 0.80; precision 0.92 vs 0.85; F1 score 0.90 vs 0.82). The ARIMA–SPC approach also demonstrated substantially lower inference time (5 s vs 15 s), indicating low computational burden compatible with real-time monitoring constraints. The findings of this study have practical applications in the development of real-time monitoring systems to detect exercise-induced fatigue. And prewhitened residual monitoring provides an interpretable and computationally efficient route for fatigue-related biomechanical anomaly detection.