Stephen Nyende-Byakika

Prof. Stephen Nyende-Byakika

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2020 in South African Journal of Chemical Engineering
Verified
Journal Article
Open access
MMMpho Muloiwa
Mpho Muloiwa
Stephen Nyende-ByakikaStephen Nyende-Byakika
Stephen Nyende-Byakika
MDMegersa Olumana Dinka
Megersa Olumana Dinka

6 December 2022 in Water Practice & Technology
Verified
Journal Article
Open access
PDF file
MMMpho Muloiwa
Mpho Muloiwa
MDM. O. Dinka
M. O. Dinka
Stephen Nyende-ByakikaStephen Nyende-Byakika
Stephen Nyende-Byakika
The biological aeration unit consumes the highest energy (67.3%) in wastewater treatment compared with physical (18.8%) and chemical (13.9%) treatment processes. The high energy consumption is caused by the supply of oxygen using air pumps/blowers and temperature that controls microorganisms' growth. The purpose of this study was to model and optimize energy consumption in the biological aeration unit. The multilayer perceptron (MLP) artificial neural network (ANN) algorithm was used to model energy consumption. The particle swarm optimization (PSO) algorithm was used to optimize the energy consumption model. Sensitivity analysis was performed to determine the percentage contribution of input variables towards energy consumption. The MLP ANN algorithm modelled energy consumption successfully and produced R², RMSE, and MSE of 0.89, 0.0265, and 0.00070, respectively, during the testing phase. The PSO algorithm optimized energy consumption successfully and produced a global solution of 0.993 kWh/m³. The percentage reduction between the lowest measured and optimized energy consumption was 38.4%. Aeration period (81%) and temperature (10.7%) contributed the highest towards energy consumption. In conclusion, temperature played a significant role in energy consumption compared with airflow rate (4.2%). When the temperature is conducive to allowing the growth of microorganisms, the removal of COD and ammonia will be rapid resulting in low energy consumption.

16 November 2022 in South African Journal of Chemical Engineering
Verified
Journal Article
Open access
MMM. Muloiwa
M. Muloiwa
MDM.O. Dinka
M.O. Dinka
Stephen Nyende-ByakikaStephen Nyende-Byakika
Stephen Nyende-Byakika

25 November 2022 in Water Science & Technology
Verified
Journal Article
Open access
PDF file
MMMpho Muloiwa
Mpho Muloiwa
MDMegersa Dinka
Megersa Dinka
Stephen Nyende-ByakikaStephen Nyende-Byakika
Stephen Nyende-Byakika
The biological treatment process (BTP) is responsible for removing COD and ammonia using microorganisms present in wastewater. The BTP consumes large quantities of energy due to the transfer of oxygen using air pumps/blowers. Energy consumption in the BTP is due to low solubility of oxygen, which results in low aeration efficiency (AE). The aim of the study was to develop an AE model that can be used to monitor the performance of the BTP. MLP ANN algorithm was used to model AE in the BTP. The performance of the AE model was evaluated using R2, MSE, and RMSE. Sensitivity analysis was performed on the AE model to determine variables that drive AE. The results of the study showed that MLP ANN algorithm was able to model AE. R2, MSE, and RMSE results were 0.939, 0.0025, and 0.05 respectively during testing phase. Sensitivity analysis results showed that temperature (34.6%), COD (21%), airflow rate (19.1%), and OTR/KLa (15.7%) drive AE. At high temperatures, the viscosity of wastewater is low which enables oxygen to penetrate the wastewater, resulting in high AE. The AE model can be used to predict the performance of the BTP, which will assist in minimizing energy consumption.

1 December 2018 in Water Practice & Technology
Verified
Journal Article
Closed access
PDF file
Stephen Nyende-ByakikaStephen Nyende-Byakika
Stephen Nyende-Byakika
VFV. S. Frenkel
V. S. Frenkel
YCY. Cohen
Y. Cohen
In water supply management it is commonly thought that consumer satisfaction depends mostly on the amount of water discharged to a network. Because of this, complaints about inadequate supply are usually blamed on insufficient production. However, a recent study by the author indicated that the water distribution and supply network is equally important. A water network modelled in EPANET2 hydraulic solver was subjected to various conditions and constraints, and its responses analyzed. For water to be supplied efficiently, and in addition to augmenting production, greater emphasis must be put on the distribution system. This must be designed and optimized appropriately, to deliver water at the required pressure and discharge. In particular, higher pressures can be obtained when larger diameter pipes are used because friction losses are reduced, thereby reducing pumping costs. One way to improve pressure is by limiting demand.

1 April 2024 in Water and Environment Journal
Verified
Journal Article
Open access
PDF file
MMMpho Muloiwa
Mpho Muloiwa
MDMegersa Olumana Dinka
Megersa Olumana Dinka
Stephen Nyende-ByakikaStephen Nyende-Byakika
Stephen Nyende-Byakika
The solubility of oxygen in a liquid is limited/restricted by the gas–liquid film that prevents gas from dissolving in wastewater. Oxygen in the biological aeration unit (BAU) is required by microorganisms to survive and eliminate organic and inorganic matter. This study developed a volumetric mass transfer coefficient (KLa) model using Artificial Neural Network (ANN) algorithm. The performance of the KLa model was evaluated using coefficient of determination (R2), mean squared error (MSE), and root mean squared error (RMSE). KLa model produced R2 (0.852), MSE (0.0006), and RMSE (0.0245) during the testing phase. Biomass concentration (22.29%), aeration period (20.55%), and temperature (19.63%) contributed the highest towards the KLa model. KLa model showed that the BAU should be operated at high temperatures (35°C), low biomass concentration (1.65 g/L), and low aeration period (1 h) instead of high airflow (30 L/min). Temperature should be included in the modelling of the BAU, to achieve optimum KLa.