Sorin Cristian Popa

Mr. Sorin Cristian Popa

Pathfinder Medical, London, City of London, UK
+1
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2009 in Monthly Notices of the Royal Astronomical Society
Verified
Journal Article
Open access
CJC. E. Jones
C. E. Jones
AMA. Molak
A. Molak
TST. A. A. Sigut
T. A. A. Sigut
AKA. de Koter
A. de Koter
ALA. Lenorzer
A. Lenorzer
Sorin Cristian PopaSorin Cristian Popa
Sorin Cristian Popa

1 January 2021 in EJVES Vascular Forum
Verified
Journal Article
Open access
DLDennis Lui
Dennis Lui
Sorin Cristian PopaSorin Cristian Popa
Sorin Cristian Popa
Robert DickinsonRobert Dickinson
Robert Dickinson
LPLorenzo Patrone
Lorenzo Patrone
Endovascular treatment of challenging infra-inguinal peripheral vascular disease is increasingly common because of new techniques and improved tools. The use of a novel electrically guided 5 F re-entry catheter is presented. By emitting a minute electrical field, detected by a target wire inserted from an opposing access, the catheter's orientation is accurately displayed to the operator, allowing precise re-entry without the need for fluoroscopic alignment. An 84 year old man with tissue loss was treated for a long occlusion of the superficial femoral artery and tibial vessels. Successful subintimal recanalisation was achieved with the help of the ePATH re-entry catheter, restoring inline flow to the foot. This re-entry catheter benefits from an intuitive alignment method, smaller profile, and operator adjustable needle travel, making it a versatile tool for endovascular cases.

25 March 2014 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
Sorin Cristian PopaSorin Cristian Popa
Sorin Cristian Popa
KFKyle Fricke
Kyle Fricke
JDJohn Dubois
John Dubois
AKAnil T. G. Kottam
Anil T. G. Kottam
RSRobert Sobot
Robert Sobot
A full set of finite-element method (FEM) studies of the catheter within a cylindrical cuvette and within an elliptical cuvette are presented along with novel insight on the fundamental electromagnetic properties of the catheter. An in vitro experiment with modified small mouse pressure-volume catheters was conducted and the results are presented as a validation of the FEM models. In addition, sensitivity analysis on the electrode size and position is conducted and the results allow for a novel calibration factor based on catheter geometry to be presented. This calibration factor is used in conjunction with Wei's conductance volume equations to reduce the average measured error in cuvette volume measurements from 26.5% to 5%.

29 June 2022 in Sensors
Verified
Journal Article
Open access
PDF file
MDMamadou Diallo
Mamadou Diallo
CEClemens Eder
Clemens Eder
DBDaniel Brasier
Daniel Brasier
Sorin Cristian PopaSorin Cristian Popa
Sorin Cristian Popa
Robert DickinsonRobert Dickinson
Robert Dickinson
Percutaneous procedures to divert blood flow from one blood vessel to another can be performed with intravascular catheters but demand a method to align a crossing needle from one vessel to another. Fluoroscopic imaging alone is not adequate, and it is preferable to have a sensor on one catheter that detects the correct alignment of an incoming needle. This can be implemented by generating dipole electric fields from the crossing catheter which are detected by a receiving catheter in the target vessel and, thus, can calculate and display the degree of alignment, permitting the operator to rotate the crossing catheter to guarantee alignment when deploying a crossing needle. Catheters were built using this concept and evaluated in vitro. The results show that accurate alignment is achieved, and a successful crossing can be made. The concept is being further developed for further clinical evaluation.