Stéphane Marc Ernest Montavon

Dr. Stéphane Marc Ernest Montavon

Department of Equine Surgery, Vetsuisse Fakultät Zürich, Zürich, Switzerland
orcid
DVM, Certified in Equine Rehabilitation

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2013 in Preventive Veterinary Medicine
Verified
Journal Article
Closed access
AEAgneta Egenvall
Agneta Egenvall
CTCarolyne Tranquille
Carolyne Tranquille
ALA.C. Lönnell
A.C. Lönnell
CBC. Bitschnau
C. Bitschnau
AOA. Oomen
A. Oomen
LRLars Roepstorff
Lars Roepstorff

16 February 2016 in Equine Veterinary Journal
Verified
Journal Article
Open access
PDF file
MFM. Fries
M. Fries
Stéphane Marc Ernest MontavonStéphane Marc Ernest Montavon
Stéphane Marc Ernest Montavon
CSC. Spadavecchia
C. Spadavecchia
OLOlivier Levionnois
Olivier Levionnois
Summary: Reasons for performing study: Methods of evaluating locomotor activity can be useful in efforts to quantify behavioural activity in horses objectively. Objectives: To evaluate whether an accelerometric device would be adequate to quantify locomotor activity and step frequency in horses, and to distinguish between different levels of activity and different gaits. Study design: Observational study in an experimental setting. Methods: Dual‐mode (activity and step count) piezo–electric accelerometric devices were placed at each of 4 locations (head, withers, forelimb and hindlimb) in each of 6 horses performing different controlled activities including grazing, walking at different speeds, trotting and cantering. Both the activity count and step count were recorded and compared by the various activities. Statistical analyses included analysis of variance for repeated measures, receiver operating characteristic curves, Bland–Altman analysis and linear regression. Results: The accelerometric device was able to quantify locomotor activity at each of the 4 locations investigated and to distinguish between gaits and speeds. The activity count recorded by the accelerometer placed on the hindlimb was the most accurate, displaying a clear discrimination between the different levels of activity and a linear correlation to speed. The accelerometer placed on the head was the only one to distinguish specifically grazing behaviour from standing. The accelerometer placed on the withers was unable to differentiate different gaits and activity levels. The step count function measured at the hindlimb was reliable but the count was doubled at the walk. Conclusions: The dual‐mode accelerometric device was sufficiently accurate to quantify and compare locomotor activity in horses moving at different speeds and gaits. Positioning the device on the hindlimb allowed for the most accurate results. The step count function can be useful but must be manually corrected, especially at the walk.

22 April 2023 in Sensors
Verified
Journal Article
Open access
PDF file
KGKévin Cédric Guyard
Kévin Cédric Guyard
Stéphane Marc Ernest MontavonStéphane Marc Ernest Montavon
Stéphane Marc Ernest Montavon
JBJonathan Bertolaccini
Jonathan Bertolaccini
MDMichel Deriaz
Michel Deriaz
Quantitative information on how well a horse clears a jump has great potential to support the rider in improving the horse’s jumping performance. This study investigated the validation of a GPS-based inertial measurement unit, namely Alogo Move Pro, compared with a traditional optical motion capture system. Accuracy and precision of the three jumping characteristics of maximum height (Zmax), stride/jump length (lhorz), and mean horizontal speed (vhorz) were compared. Eleven horse–rider pairs repeated two identical jumps (an upright and an oxer fence) several times (n = 6 to 10) at different heights in a 20 × 60 m tent arena. The ground was a fiber sand surface. The 24 OMC (Oqus 7+, Qualisys) cameras were rigged on aluminum rails suspended 3 m above the ground. The Alogo sensor was placed in a pocket on the protective plate of the saddle girth. Reflective markers placed on and around the Alogo sensor were used to define a rigid body for kinematic analysis. The Alogo sensor data were collected and processed using the Alogo proprietary software; stride-matched OMC data were collected using Qualisys Track Manager and post-processed in Python. Residual analysis and Bland–Altman plots were performed in Python. The Alogo sensor provided measures with relative accuracy in the range of 10.5–20.7% for stride segments and 5.5–29.2% for jump segments. Regarding relative precision, we obtained values in the range of 6.3–14.5% for stride segments and 2.8–18.2% for jump segments. These accuracy differences were deemed good under field study conditions where GPS signal strength might have been suboptimal.

21 August 2019 in Veterinary Surgery
Verified
Journal Article
Closed access
PDF file
MBMarco F. Bryner
Marco F. Bryner
SHSeamus E. Hoey
Seamus E. Hoey
Stéphane Marc Ernest MontavonStéphane Marc Ernest Montavon
Stéphane Marc Ernest Montavon
AFAnton E. Fürst
Anton E. Fürst
JKJan Kümmerle
Jan Kümmerle

17 January 2025 in Sensors
Verified
Journal Article
Open access
PDF file
KGKévin Cédric Guyard
Kévin Cédric Guyard
JBJonathan Bertolaccini
Jonathan Bertolaccini
Stéphane Marc Ernest MontavonStéphane Marc Ernest Montavon
Stéphane Marc Ernest Montavon
MDMichel Deriaz
Michel Deriaz
Accurate localization is crucial for numerous applications. While several methods exist for outdoor localization, typically relying on GPS signals, these approaches become unreliable in environments subject to a weak GPS signal or GPS outage. Many researchers have attempted to address this limitation, primarily focusing on real-time solutions. However, for applications that do not require real-time localization, these methods remain suboptimal. This paper presents a novel Transformer-based bidirectional encoder approach to address, in postprocessing, the localization challenges during GPS weak signal phases or GPS outages. Our method predicts the velocity during periods of weak or lost GPS signals and calculates the position through bidirectional velocity integration. Additionally, it incorporates position interpolation to ensure smooth transitions between active GPS and GPS outage phases. Applied to a dataset tracking horse positions—which features velocities up to 10 times those of pedestrians and higher acceleration—our approach achieved an average trajectory error below 3 m, while maintaining stable relative distance errors regardless of the GPS outage duration.

15 July 2022 in Veterinary and Comparative Orthopaedics and Traumatology
Verified
Journal Article
Closed access
PDF file
LGLevin Gfrerer
Levin Gfrerer
SMSilvain Arsene Michel
Silvain Arsene Michel
AFAnton E. Fürst
Anton E. Fürst
GPGabor Piskoty
Gabor Piskoty
BWBernhard Weisse
Bernhard Weisse
MJMichelle A. Jackson
Michelle A. Jackson
Objective The goal of this study was to generate mandibular fractures in three regions of the diastema using a metal impactor to simulate a kick from a horse and to determine the mean deceleration in the initial phase of the impact event, the maximum contact force, the impact energy necessary to create a fracture and the duration of the impact. Study Design Thirty heads of horses aged between 5 and 20 years and euthanatized for various reasons were used. The heads were attached to a steel bar at the occiput at an axial angle of 45 degrees so that the body of the mandible was positioned horizontally and directly under the trajectory of the impactor. A 2 kg solid impactor was dropped with velocities of 6 to 14 m/s to simulate a kick from a horse. The impact was recorded using a high-speed video camera with a frame rate of 30,000 frames per second. Radiographs of the heads were obtained before and after the simulated kick. Results Mandibular fractures with configurations similar to those seen in clinical practice were generated at all three locations. The mean deceleration increased with impact velocity and with more cranially located impact positions. Absorbed energy increased with increasing impact velocity when no fracture was generated. Conclusion The susceptibility to experimental fracture of the diastema increased from rostral to caudal locations, which is most probably caused by decreasing mandibular bone strength and an increase in the curvature at the lateroventral aspect of the mandible in that region. Physical parameters depended on fracture occurrence and type.