mustapha tahaikt

Prof. Dr. mustapha tahaikt

Université Ibn-Tofail, Kenitra, Rabat-Salé-Kénitra, Morocco
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 December 2023 in Water Science & Technology
Verified
Journal Article
Open access
PDF file
FAfatima zahra Addar
fatima zahra Addar
IMIdrisse Mohamed
Idrisse Mohamed
SKSarra Kitanou
Sarra Kitanou
MTmustapha tahaikt
mustapha tahaikt
AEAzzedine Elmidaoui
Azzedine Elmidaoui
MTMohamed Taky
Mohamed Taky
The performance of three anion-exchange membranes (AEMs) in the fluoride ions reduction by electrodialysis (ED) is performed on real and synthetic water. The electric potential method measures the potential difference (PD) between two synthetic anion solutions separated by ACS, AFN and AXE membranes. The selectivity of these three AEMs coupled with the membrane CMX, is a cation-exchange membrane (CEM) towards different ions. The removal rate is influenced by the thickness of the polarization layer (PL) which reduces the material transfer and provides an additional barrier. The greater the thickness δ of the PL, the longer the passage time and consequently the removal rate of anions is small. Using the unstirred layer model, δ for each ion will be determined. According to the potential measurement method, none of the tested AEMs are selective to fluoride ions and the order of selectivity is as follows: AFN> AXE> ACS. Best membrane couple selected for fluoride ion removal is ACS/CMX and ion selectivity follows the order: Cl−> NO−3>F−> HCO−3> SO42−. For ACS membrane, both the demineralization rate (DR) and δ of fluoride ions are influenced by the initial concentration of the co-ion according to the following order: NO−3> Cl−> HCO−3> SO2−4.

16 October 2024 in Environmental Monitoring and Assessment
Verified
Journal Article
Closed access
PDF file
IDIkram Daou
Ikram Daou
YDYounes Dehmani
Younes Dehmani
HMHamou MOUSSOUT
Hamou MOUSSOUT
Dison S FrancoDison S Franco
Dison S Franco
Jordana GeorginJordana Georgin
Jordana Georgin
NMNoureddine El Messaoudi
Noureddine El Messaoudi

20 February 2022 in Desalination and Water Treatment
Verified
Journal Article
Open access
MTmustapha tahaikt
mustapha tahaikt
EEElazhar, Fatima Elazhar
Elazhar, Fatima Elazhar
IMIdrisse Mohamed
Idrisse Mohamed
HZHajar Zeggar
Hajar Zeggar
MTMohamed Taky
Mohamed Taky
AEAzzeddine Elmidaouia
Azzeddine Elmidaouia

20 February 2022 in Desalination and Water Treatment
Verified
Journal Article
Open access
MZMohamed Zait
Mohamed Zait
SBSoukayna Benalla
Soukayna Benalla
BBBasma Bachiri
Basma Bachiri
MTmustapha tahaikt
mustapha tahaikt
DRISS DHIBADRISS DHIBA
DRISS DHIBA
MTMohamed Taky
Mohamed Taky

7 February 2022 in Desalination and Water Treatment
Verified
Journal Article
Open access
HZHajar Zeggar
Hajar Zeggar
JTJamal Touir
Jamal Touir
SESoufian El-Ghzizel
Soufian El-Ghzizel
EEElazhar, Fatima Elazhar
Elazhar, Fatima Elazhar
MTmustapha tahaikt
mustapha tahaikt
MTMohamed Taky
Mohamed Taky

9 April 2024 in ChemistryOpen
Verified
Journal Article
Open access
PDF file
MHMohamed Hazra
Mohamed Hazra
MOMohamed Ouzbair
Mohamed Ouzbair
IMIbrahim Maolida
Ibrahim Maolida
OEOmar Elrhaouat
Omar Elrhaouat
MTmustapha tahaikt
mustapha tahaikt
SBSakina Belhamidi
Sakina Belhamidi
In this work, we investigated the feasibility of ammonium removal by electrodialysis (ED), a well‐known electro‐membrane process, based on the selective migration of anions and cations through anion exchange membranes (AEMs) and cation exchange membranes (CEMs). ED experiments are performed using a laboratory pilot. The ion exchange membranes (IEMs) pair used is AXE/CMX, AXE as an AEMs and CMX as a CEMs. The first tests are performed with real groundwater solutions from Kenitra city (Morocco), spiked with an initial concentration of 3 mg/L NH4Cl. The results gave a specific demineralization (SD) to NH4+ ions of 84.60 %; for a demineralization rate (DR) of 80 % and a time of 60 min. The multivariate principal component analysis (PCA) presents a total inertia of 99.23 %, the majority of the variables of which are positively correlated on the C1 axis with a variance of 95.5 % than that of C2 of 3.78 %. The quality of the diluted water determined by the Legrand‐Poirier method showed that the water was aggressive and that the addition of 4.54 mg/L Ca2+ was necessary to balance the water and make it fit for human consumption.