Xiaojian Cao

Dr. Xiaojian Cao

Nantong University
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 January 2018 in Metals
Verified
Journal Article
Open access
PDF file
Xiaojian CaoXiaojian Cao
Xiaojian Cao
LXLuopeng Xu
Luopeng Xu
XXXiaoli Xu
Xiaoli Xu
Qingyuan WangQingyuan Wang
Qingyuan Wang
The influence of ultrasonic nanocrystal surface modification (UNSM) on the fatigue fracture characteristics of Ti6Al4V was investigated. Two groups of specimens were separated due to different heat treatment conditions. Group one was stress-relief annealed at 650 °C, and group two was then treated with solid solution-aging. UNSM with the conditions of a static load of 25 N, vibration amplitude of 30 μm, and 36,000 strikes per unit produced about 40 μm surface severe plastic deformation (SPD) layers on both groups of specimens. UNSM improved the microhardness and the compressive residual stress. UNSM also helped achieve a neat surface, almost without changing the surface roughness. The fatigue strengths of these two groups were improved by 7% and 11.7%, respectively. After UNSM, fatigue cracks mainly initiated from the surface of the specimen before the fatigue life of 106 cycles, while they appeared at the internal compress deformed α-phase at the zone between the SPD layer and the core after the fatigue life of 106 cycles. The cracks usually extended along the deformation overflow bands and the process traces on the surface. Through the change of micro-dimples in the fatigue final rupture region, nanocrystals were achieved in the SPD layer. The crystal slip and the surface remodeling together influenced the energy field of crack evolution.

18 October 2017 in Metals
Verified
Journal Article
Open access
PDF file
Xiaojian CaoXiaojian Cao
Xiaojian Cao
XXXiaoli Xu
Xiaoli Xu
CWChong Wang
Chong Wang
Young Sik  PyunYoung Sik Pyun
Young Sik Pyun
Qingyuan WangQingyuan Wang
Qingyuan Wang
The effect of ultrasonic nanocrystal surface modification (UNSM) on the fatigue behavior of Ti6Al4V (TC4) in simulated body fluid (SBF) was investigated. UNSM with the condition of a static load of 25 N, vibration amplitude of 30 μm and 36,000 strikes per unit produced about 35 μm surface severe plastic deformation (SPD) layers on the TC4 specimens. One group was treated with a hybrid surface treatment (UNSM + TiN film). UNSM technique improves the micro hardness and the compressive residual stress. The surface roughness is increased slightly, but it can be remarkably improved by the TiN film. The fatigue strength of TC4 is improved by about 7.9% after UNSM. Though the current density of corrosion is increased and the pitting corrosion is accelerated, UNSM still improved the fatigue strength of TC4 after pre-soaking in SBF by 10.8%. Interior cracks initiate at the deformed carbide and oxide inclusions due to the ultrasonic impacts of UNSM. Corrosion products are always observed at the edge of fracture surface to both interior cracks and surface cracks. Coating a TiN film on the UNSMed surface helps to improve the whole properties of TC4 further.

2 May 2020 in Materials
Verified
Journal Article
Open access
PDF file
ZCZhangjianing Cheng
Zhangjianing Cheng
Xiaojian CaoXiaojian Cao
Xiaojian Cao
XXXiaoli Xu
Xiaoli Xu
SQSHEN Qiangru
SHEN Qiangru
TYTianchong Yu
Tianchong Yu
JJJiang Jin
Jiang Jin
The effect of nano grain surface layer generated by ultrasonic impact on the fatigue behaviors of a titanium alloy Ti3Zr2Sn3Mo25Nb (TLM) was investigated. Three vibration strike-numbers of 24,000 times, 36,000 times and 48,000 times per unit are chosen to treat the surface of TLM specimens. Nanocrystals with an average size of 30 nm are generated. The dislocation motion plays an important role in the transformation of nanograins. Ultrasonic surface impact improves the mechanical properties of TLM, such as hardness, surface residual stress, tensile strength and fatigue strength. More vibration strike numbers will cause a higher enhancement. With a vibration strike number of 48,000 times per square millimeter the rotating-bending fatigue strength of TLM at 107 cycles is improved by 23.7%. All the fatigue cracks initiate from the surface of untreated specimens, while inner cracks appear after the fatigue life of 106 cycles with the ultrasonic surface impact. The crystal slip in the crack initiation zone is the main way of growth for microcracks. Crack cores are usually formed at the junction of crystals. The stress intensity factor of TLM titanium alloy is approximately 7.0 MPa·m1/2.

25 July 2024 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JZJiangpei Zhu
Jiangpei Zhu
MZMei-Ling Zhuang
Mei-Ling Zhuang
YQYuting Qi
Yuting Qi
BCBin Chen
Bin Chen
Xiaojian CaoXiaojian Cao
Xiaojian Cao
In the present study, effect of ultrasonic impact treatment (UIT) on the microstructural characterization and mechanical properties of 316L stainless steel (hereinafter referred to as 316L) was investigated experimentally. The fatigue fracture mechanism of 316L before and after UIT was revealed. The experimental results indicated that the martensitic grain size induced at the impact edge was about 2.00 Å. The surface modified 316L formed a gradient nanostructure and induced a martensitic phase transformation. The hardness of the surface layer of the modified 316L was twice the hardness of its matrix. The tensile strengths of 316L before and after UIT were 576 MPa and 703 MPa, respectively. The stretching stripes of 316L were more disordered after UIT. The fatigue strengths of 316L before and after UIT were 267 MPa and 327 MPa, respectively. The fatigue cracking of 316L started from the austenite grain boundaries. The fatigue fracture surface was relatively rough. The fatigue crack sources of the modified 316L came from internal inclusions. The inclusions were oxides dominated by SiO2. As the stress range increased, the crack initiation site migrated to the interior and the fatigue fracture surface became flatter.

2 April 2026 in Engineering Failure Analysis
Verified
Journal Article
Closed access
WSWenhui Sun
Wenhui Sun
YZYu Zhou
Yu Zhou
FWFaquan Wu
Faquan Wu
Xiaojian CaoXiaojian Cao
Xiaojian Cao
SYShuyang Yu
Shuyang Yu

31 December 2020 in Materials
Verified
Journal Article
Open access
PDF file
Xiaojian CaoXiaojian Cao
Xiaojian Cao
ZJZhu Jiangpei
Zhu Jiangpei
FGFei Gao
Fei Gao
ZGzhu gao
zhu gao
By means of the ultrasonic surface impact (amplitude of 30 μm, strike number of 48,000 times/mm2), nanograins have been achieved in the surfaces of both Ti6Al4V(TC4) and Ti3Zr2Sn3Mo25Nb(TLM) titanium alloys, mainly because of the dislocation motion. Many mechanical properties are improved, such as hardness, residual stress, and roughness. The rotating–bending fatigue limits of TC4 and TLM subjected to ultrasonic impact are improved by 13.1% and 23.7%, separately. Because of the bending fatigue behavior, which is sensitive to the surface condition, cracks usually initiate from the surface defects under high stress amplitude. By means of an ultrasonic impact tip with the size of 8 mm, most of the inner cracks present at the zone with a depth range of 100~250 μm in the high life region. The inner crack core to TC4 usually appears as a deformed long and narrow α-phase, while the cracks in TLM specimens prefer to initiate at the triple grain boundary junctions. This zone crosses the grain refined layer and the deformed coarse grain layer. With the gradient change of elastic parameters, the model shows an increase of normal stress at this zone. Combined with the loss of plasticity and toughness, it is easy to understand these fatigue behaviors.