Muhammad Tayyab Chaudhry

Dr. Muhammad Tayyab Chaudhry

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Haseeb Rehman KhanHaseeb Rehman Khan
Haseeb Rehman Khan
ZGzeeshan gillani
zeeshan gillani
MJMuhammad Hasan Jamal
Muhammad Hasan Jamal
AAAtifa Athar
Atifa Athar
Muhammad Tayyab ChaudhryMuhammad Tayyab Chaudhry
Muhammad Tayyab Chaudhry
Ming ChenMing Chen
Ming Chen
Climate change and the COVID-19 pandemic have disrupted the food supply chain across the globe and adversely affected food security. Early estimation of staple crops can assist relevant government agencies to take timely actions for ensuring food security. Reliable crop type maps can play an essential role in monitoring crops, estimating yields, and maintaining smooth food supplies. However, these maps are not available for developing countries until crops have matured and are about to be harvested. The use of remote sensing for accurate crop-type mapping in the first few weeks of sowing remains challenging. Smallholder farming systems and diverse crop types further complicate the challenge. For this study, a ground-based survey is carried out to map fields by recording the coordinates and planted crops in respective fields. The time-series images of the mapped fields are acquired from the Sentinel-2 satellite. A deep learning-based long short-term memory network is used for the accurate mapping of crops at an early growth stage. Results show that staple crops, including rice, wheat, and sugarcane, are classified with 93.77% accuracy as early as the first four weeks of sowing. The proposed method can be applied on a large scale to effectively map crop types for smallholder farms at an early stage, allowing the authorities to plan a seamless availability of food.

6 February 2015 in Frontiers of Information Technology & Electronic Engineering
Verified
Journal Article
Closed access
PDF file
Muhammad Tayyab ChaudhryMuhammad Tayyab Chaudhry
Muhammad Tayyab Chaudhry
TLTeck Ling
Teck Ling
SHS. A. Hussain
S. A. Hussain
XLXin-Zhu Lu
Xin-Zhu Lu
Rise in inlet air temperature increases the corresponding outlet air temperature from the server. As an added effect of rise in inlet air temperature, some active servers may start exhaling intensely hot air to form a hotspot. Increase in hot air temperature and occasional hotspots are an added burden on the cooling mechanism and result in energy wastage in data centers. The increase in inlet air temperature may also result in failure of server hardware. Identifying and comparing the thermal sensitivity to inlet air temperature for various servers helps in the thermal-aware arrangement and location switching of servers to minimize the cooling energy wastage. The peak outlet temperature among the relocated servers can be lowered and even be homogenized to reduce the cooling load and chances of hotspots. Based upon mutual comparison of inlet temperature sensitivity of heterogeneous servers, this paper presents a proactive approach for thermal-aware relocation of data center servers. The experimental results show that each relocation operation has a cooling energy saving of as much as 2.1 kW·h and lowers the chances of hotspots by over 77%. Thus, the thermal-aware relocation of servers helps in the establishment of green data centers.

1 January 2014 in The Scientific World Journal
Verified
Journal Article
Open access
PDF file
Muhammad Tayyab ChaudhryMuhammad Tayyab Chaudhry
Muhammad Tayyab Chaudhry
TLTeck Ling
Teck Ling
SHS. A. Hussain
S. A. Hussain
AMAtif Manzoor
Atif Manzoor
A rise in inlet air temperature may lower the rate of heat dissipation from air cooled computing servers. This introduces a thermal stress to these servers. As a result, the poorly cooled active servers will start conducting heat to the neighboring servers and giving rise to hotspot regions of thermal stress, inside the data center. As a result, the physical hardware of these servers may fail, thus causing performance loss, monetary loss, and higher energy consumption for cooling mechanism. In order to minimize these situations, this paper performs the profiling of inlet temperature sensitivity (ITS) and defines the optimum location for each server to minimize the chances of creating a thermal hotspot and thermal stress. Based upon novel ITS analysis, a thermal state monitoring and server relocation algorithm for data centers is being proposed. The contribution of this paper is bringing the peak outlet temperatures of the relocated servers closer to average outlet temperature by over 5 times, lowering the average peak outlet temperature by 3.5% and minimizing the thermal stress.

30 March 2022 in Energies
Verified
Journal Article
Open access
PDF file
MJMuhammad Hasan Jamal
Muhammad Hasan Jamal
Muhammad Tayyab ChaudhryMuhammad Tayyab Chaudhry
Muhammad Tayyab Chaudhry
Usama TahirUsama Tahir
Usama Tahir
Furqan RustamFurqan Rustam
Furqan Rustam
Soojung HurSoojung Hur
Soojung Hur
IAImran Ashraf
Imran Ashraf
Data center servers located in thermal hotspot regions receive inlet air at a higher than the set temperature and thus generate comparatively high outlet temperature. Consequently, there is a rise in energy that is consumed to cool down the servers that otherwise would undergo reliability hazards. The workload deployment across the servers should be resilient to thermal hotspots to ensure smooth performance. In a heterogeneous data center environment, an equally important fact is the placement of the servers in a thermal hotspot-aware manner to lower the peak outlet temperatures. These approaches can be applied proactively with the help of outlet temperature prediction. This paper presents the hotspot adaptive workload deployment algorithm (HAWDA) and hotspot aware server relocation algorithm (HASRA) based on thermal profiling regarding outlet temperature prediction. HAWDA deploys workload on servers in a thermal-efficient manner and HASRA optimizes the server location in thermal hotspot regions to lower the peak outlet temperatures. Performance comparison is carried out to analyze the efficacy of HAWDA against the TASA and GRANITE algorithms. Results suggest that HAWDA provides average peak utilization of the servers similar to GRANITE and TASA without additional burden on the cooling mechanism, with and without server relocation, as HAWDA minimizes the peak outlet temperature.

12 January 2026 in IEEE Sensors Journal
Verified
Journal Article
Closed access
UAUsman Ali
Usman Ali
AZAli Zia
Ali Zia
WAWaqas Ali
Waqas Ali
URUmer Ramzan
Umer Ramzan
ARAbdul Rehman
Abdul Rehman
Wei XiangWei Xiang
Wei Xiang
Reliable induction motor (IM) fault diagnosis is vital for industrial safety and operational continuity, mitigating costly unplanned downtime. Conventional approaches often struggle to capture complex multimodal signal relationships, are constrained to unimodal data or single fault types, and degrade under noise or cross-domain shifts. We propose the multimodal hypergraph contrastive attention network (MM-HCAN), a unified framework that integrates multihead attention with a hypergraph architecture and contrastive learning (CL) to jointly model global and localized intra- and inter-modal dependencies beyond Euclidean embedding spaces. MM-HCAN’s gains are driven by three innovations: 1) a structured multimodal fusion scheme with dynamically constructed hyperedges encoding higher order cross-modal relationships; 2) modality-specific hypergraph Laplacians for fine-grained, context-aware embedding refinement; and 3) triplet-based CL performed directly on the hypergraph manifold, yielding more discriminative, topologyrespecting representations. The model enables simultaneous diagnosis of bearing, stator, and rotor faults, addressing the engineering need for consolidated diagnostics. Evaluated on three real-world benchmarks, MM-HCAN achieves up to 99.82% accuracy with strong cross-domain generalization and robustness to noise. An ablation study confirms the contribution of each component. MM-HCAN offers a scalable and robust solution for comprehensive multifault diagnosis, supporting predictive maintenance and extended asset longevity in industrial environments. Code is available at https://github.com/EngrUsmaanAli/MM-HCAN

1 March 2016 in Malaysian Journal of Computer Science
Verified
Journal Article
Open access
PDF file
Muhammad Tayyab ChaudhryMuhammad Tayyab Chaudhry
Muhammad Tayyab Chaudhry
CCChun Yong Chong
Chun Yong Chong
TLTeck Ling
Teck Ling
SRSaim Rasheed
Saim Rasheed
JKJongWon Kim
JongWon Kim
The energy dissipated as heat for each utilization level of a data center server is empirically measured and stored as the thermal-profile. These thermal-profiles are used to predict the outlet temperatures of the related servers for current and future utilization. The predicted outlet temperature is an important parameter for energy efficient thermal-aware workload scheduling and workload migration in green data centers. This paper presents three models for outlet temperature prediction on virtualized data center servers based on thermal-profile. The best case scenario managed to predict the outlet temperature with a negligible error of 0.3 degree Celsius.