Thejaraju Rajashekaraiah

Dr. Thejaraju Rajashekaraiah

Christ University, Bengaluru, India

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 October 2019 in International Journal of Engineering and Advanced Technology
Verified
Journal Article
Closed access
RGRavichandran G
Ravichandran G
RGRathnakar G
Rathnakar G
SNSANTHOSH N.
SANTHOSH N.
TRThejaraju Rajashekaraiah
Thejaraju Rajashekaraiah
Polymer nanocomposites containing various types of reinforcements and fillers are oftenly used in applications such as sliding elements in the machine and automotive parts, gear assemblies etc., in which tribological performance parameters viz. friction and wear are the major issues. In this work, the specific wear rate of HNT filler loading (0-4wt %) in Glass-Epoxy nanocomposites fabricated by vacuum bagging technique are evaluated experimentally. For this purpose, the specimens are prepared and tests are conducted as per the ASTM G-99 standard for a number of trials with the assistance of a pin-on-disc machine by varying load and speed values, keeping time and track diameter constant. The results obtained from experiments reveals that reduction in specific wear rate and the amount of material loss is quite significant for HNT loaded specimens when compared with neat sample even at higher operating conditions. This indicates that HNT comprises of hard ceramic elements viz. SiO2 and Al2O3 which eventually enhances the antiwear behaviour of prepared nanocomposites. Finally, a study on wear mechanisms and morphologies are carried out by analyzing the worn surfaces through SEM micrographs.

1 January 2019 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
TRThejaraju Rajashekaraiah
Thejaraju Rajashekaraiah
MMManohar Joel Mura
Manohar Joel Mura
RSRashmi Sharasthantra
Rashmi Sharasthantra
GSGotimayum Sachidev Sharma
Gotimayum Sachidev Sharma

1 October 2020 in Journal of Thermal Engineering
Verified
Journal Article
Closed access
PDF file
TRThejaraju Rajashekaraiah
Thejaraju Rajashekaraiah
GBGirisha Kanuvanahalli B
Girisha Kanuvanahalli B
SMSh Manjunath
Sh Manjunath
BDBs Dayananda
Bs Dayananda
The decade has witnessed great importance of numerical techniques for scientists and researchers in deciding the correctness, stability, and reliability of new designs. In the present study a numerical technique has been implemented to investigate the thermo-hydraulic performance of the Louvered winglet tape inside the tube section of the double pipe heat exchanger. The Louvered winglet tape has been examined with the slope angle of 50, 100, 150 and 210 to study their thermal characteristics. The Reynolds number 4000-30000 was examined on slope angle of 50, 100, 150 and 210 to study their flow characteristics in the turbulent domain. A smooth pipe was examined to evaluate heat transfer characteristics in terms of Nusselt number and friction coefficient over augmented tube with Louvered winglet tape. The results show a satisfactory performance of Louvered winglet tape over the smooth tube with a similar trend of friction factor, Nusselt number, and thermo-hydraulic performance index (THPI). The percentage of increment of the Nusselt number of the results is found to be 237.04%, 258.4%, 275.11%, and 289.72% when compared to smooth pipe with respect to slope angle of 50, 100, 150 and 210, respectively. The amount of increase in the friction factor in comparison with plain tube is 5.13, 6.73, 8.33, and 11.73 times of that of smooth pipe with respect to slope angle of 50, 100, 150 and 210, respectively. The Louvered winglet tape with slope angle 150 has shown to be promising with respect to higher THPI when considering with other slope angle of 50, 100, and 210. The maximum THPI of 1.85 was obtained for slope angle 150 at Re 12000. Similarly, the THPI values for other slope angle 50, 100, and 210 are 1.71, 1.78 and 1.69. In addition to better performance the Louvered winglet tape can be easily fabricated and adapted for a wide variety of heat transfer industries.

23 November 2022 in Energies
Verified
Journal Article
Open access
PDF file
SPSajna Parimita Panigrahi
Sajna Parimita Panigrahi
SMSarat Kumar Maharana
Sarat Kumar Maharana
TRThejaraju Rajashekaraiah
Thejaraju Rajashekaraiah
RSRavichandran Gopala Shetty
Ravichandran Gopala Shetty
Mohsen SharifpurMohsen Sharifpur
Mohsen Sharifpur
MAMohamed Abbas
Mohamed Abbas
Engineering applications including food processing, wastewater treatment, home heating, commercial heating, and institutional heating successfully use unglazed transpired solar collectors (UTCs). Trapping of solar energy is the prime goal of developing an unglazed transpired solar collector. The UTC is usually developed in and around the walls of the building and absorbs the solar energy to heat the air. One of the key challenges faced by the UTC designer is the prediction of performance and its warranty under uncertain operating conditions of flow variables. Some of the flow features are the velocity distribution, plate temperature, exit temperature and perforation location. The objective of the present study was to establish correlations among these flow features and demonstrate a method of predicting the performance of the UTC. Hence, a correlation matrix was generated from the dataset prepared after solving the airflow over a perforated flat UTC. Further, both strong and weak correlations of flow features were captured through Pearson’s correlation coefficient. A comparison between the outcomes from a linear regression model and that of computational simulation was showcased. The performance probability for the UTC was interlinked with correlation matrix data. The Monte Carlo simulation was used to predict the performance from random values of the flow parameters. The study showed that the difference between the free stream value of temperature and the value of temperature inside the UTC’s chamber varied between 15 and 20 °C. The probability of achieving system efficiency greater than 35% was 55.2%. This has raised the hope of recommending the UTC for drying and heating where the required temperature differential is within 20 °C.

1 January 2018 in Materials Today: Proceedings
Verified
Journal Article
Closed access
KPKirti Teja Pasupuleti
Kirti Teja Pasupuleti
SDShawn Dsouza
Shawn Dsouza
TRThejaraju Rajashekaraiah
Thejaraju Rajashekaraiah
SVShankar Venkataraman
Shankar Venkataraman
PRParvati Ramaswamy
Parvati Ramaswamy
SMS.V.S. Narayana Murty
S.V.S. Narayana Murty

7 January 2025 in Journal of Mines, Metals and Fuels
Verified
Journal Article
Open access
PDF file
TRThejaraju Rajashekaraiah
Thejaraju Rajashekaraiah
SPSajna Parimita Panigrahi
Sajna Parimita Panigrahi
GSGowtham S. Sanjai
Gowtham S. Sanjai
HDHadiya Pritesh Dulabhai
Hadiya Pritesh Dulabhai
VVV. M. Vijaykumar
V. M. Vijaykumar
The study explores the effects of different meshing techniques on the accuracy and efficiency of heat transfer and fluid dynamics simulations in a finned heat exchanger. A 3D-CAD model, developed in Autodesk Fusion, analysed aluminium fins subjected to a heat flux of 5903 W/m² under flow conditions with Reynolds numbers from 8490 to 23300. Four mesh types Tetrahedral, Polyhedral, Hexacore and Poly-Hexacore were compared. Mesh independence analysis showed that Hexacore meshes, especially Mesh Set-F (4,568,602 elements), delivered high accuracy in predicting Nusselt numbers and pressure drops, making them suitable for detailed simulations. Polyhedral meshes, particularly Mesh Set-E (498,044 elements), exhibited the best computational efficiency, ideal for resource-conscious analyses. The study underscores the trade-offs between accuracy and computational cost. Hexacore meshes are recommended for precise evaluations, while Polyhedral meshes are better suited for preliminary designs or time-sensitive applications. However, Hexacore meshes require higher computational resources, limiting their practicality for large-scale or real-time simulations. Major Findings: The findings are valuable for industries such as Heating Ventilation Air Conditioning (HVAC), automotive and electronics cooling, where heat exchanger performance predictions are crucial. By tailoring mesh configurations to specific project needs, engineers can optimise simulation accuracy and computational efficiency, enhancing design workflows and outcomes. The study provides a framework for balancing accuracy and cost, offering insights into mesh selection for effective thermal and fluid performance evaluations.