The change in transportation efficiency in the last several years has seen several new engine technologies like EVs and HEVs being more prevalent. Integration of RES wind energy technique, solar photovoltaics, and bio-energies becomes a requirement during the transition from conventional houses to smart houses and from conventional cars for energy efficient electric or hybrid vehicles. The battery of an HEV can only be charged to a certain level and similarly it should not be discharged beyond a certain limit, hence the battery state of charge (SOC) in HEVs has to be supervised by a smart battery management system (BMS). However, the current method requires improvement of the performance of SOC estimate on HEVs. Therefore, development of new SOC estimation method with DL for safe renewable energy management (REM) framework for Hybrid EV (Electric vehicles) is the prime focus of this paper is developed as DLSOC-REM. For more accurate SOC estimate, the proposed approach employs a Quaternion Generative Adversarial Network (QGAN) model. When hyper parameter tuning, the prototype is invigorated employing the Tyrannosaurus optimization algorithm (TOA) to fine-tune SOC estimate outcomes of the QGAN model. Using the QGAN model simplifies the modeling process and gives a correct representation of the battery model’s input–output relationship. The work’s originality is demonstrated by the design of the TOA-based QGAN model for SOC estimation. The suggested approach shows excellent accuracy with few errors for various drive cycles and temperatures: for US06, the RMSE stabilizes at about 0.05%, the MAE drops to 0.1%, and the MSE reaches 0.0025%.
Purpose: The purpose of this research is to explain the influence of information security monitoring and other social learning factors on employees’ security assurance behaviour. Security assurance behaviour represents employees’ intentional and effortful actions aimed towards protecting information systems. The behaviour is highly desired as it tackles the human factor within the information security framework. The authors posited that security assurance behaviour is a learned behaviour that can be enhanced by the implementation of information security monitoring.Design/methodology/approach: Theoretical framework underlying this study with six constructs, namely, subjective norm, outcome expectation, information security monitoring, information security policy, self-efficacy and perceived inconvenience, were identified as significant in determining employees’ security assurance behaviour (SAB). The influence of these constructs on SAB could be explained by social cognitive theory and is empirically supported by past studies. An online questionnaire survey as the main research instrument is adopted to elicit information on the six constructs tested in this study. Opinion from industry and academic expert panels on the relevance and face validity of the questionnaire were obtained prior to the survey administration.Findings: Findings from this research indicate that organisations will benefit from information security monitoring by encouraging security behaviours that extend beyond the security policy. This study also demonstrates that employees tend to abandon security behaviour when the behaviour is perceived as inconvenient. Hence, organisations must find ways to reduce the perceived inconvenience using various security automation methods and specialised security training. Reducing perceived inconvenience is a challenge to information security practitioners.Research limitations/implications: There are some limitations in the existing work that could be addressed in future studies. One of them is the possible social desirability bias due to the self-reported measure adopted in the study. Even though the authors have made every effort possible to collect representative responses via anonymous survey, it is still possible that the respondents may not reveal true behaviour as good conduct is generally desired. This may lead to a bias towards favourable behaviour.Practical implications: In general, the present research provides a number of significant insights and valuable information related to security assurance behaviour among employees. The major findings could assist security experts and organisations to develop better strategies and policies for information security protection. Findings of this research also indicate that organisations will benefit from information security monitoring by encouraging security behaviours that extend beyond the security policy.Social implications: In this research, the social cognitive learning theory is used to explain the influence of information security monitoring and other social learning factors on employees’ security assurance behaviour; the finding implies that monitoring emphases expected behaviours and helps to reinforce organisational norms. Monitoring may also accelerate learning when employees become strongly mindful of their behaviours. Hence, it is important for organisations to communicate the monitoring practices implemented, even more imperative whenever security monitoring employed is unobtrusive in nature. Nonetheless, care must be taken in this communication to avoid resentment and mistrust among employees.Originality/value: This study is significant in a number of ways. First, this study highlights significant antecedents of security assurance behaviour, which helps organisations to assess their current practices, which may nurture or suppress information security. Second, using users’ perspective, this study provides recommendations pertaining to monitoring as a form of information security measure. Third, this study provides theoretical contribution to the existing information security literature via the application of the social cognitive learning theory.
In the pursuit of sustainable and efficient energy solutions, Photovoltaic (PV) systems have emerged as a prominent player in the domain of renewable energy generation. Particularly, grid-tied PV systems have gained substantial attention due to their potential to contribute to stability and reliability of existing power grid infrastructure. Accordingly, an innovative approach to enhance grid supply using PV systems with Machine Learning Strategy is proposed in this research. The primary objective is to optimize voltage output from PV system while concurrently maximizing power using a novel Modified Zeta-Cuk converter, coupled with Hybrid Maximum Power Point Tracking (MPPT) algorithm combining Incremental Conductance and Bat Optimization Algorithm (InC-BOA). The stabilized DC link resulting from this process is directed to a 3-phase Voltage Source Inverter (VSI) to facilitate conversion of DC supply to AC. To further improve the efficiency and accuracy of system, current produced by inverter is subjected to Discrete Wavelet Transform (DWT) analysis followed by Principal Component Analysis (PCA) for feature extraction. The final step involves implementation of Recurrent Neural Network (RNN) controller, enabling the generation of a refined reference current. The generated reference current is then compared with actual current using Hysteresis Current Controller (HCC). This comparison yields an output which is subsequently employed to Pulse Width Modulation (PWM) generator facilitating the achievement of effective grid synchronization, enhancing overall performance and stability of the system. The validation is performed using MATLAB Simulink software and the outcomes reveals the dominance of proposed work.
This manuscript presents a grid-connected photovoltaic (PV) system employing a modular multilevel inverter (MMI) topology with an advanced hybrid control technique. The proposed MAO-RERNN control method integrates the Mexican Axolotl Optimization (MAO) algorithm with a Recalling-Enhanced Recurrent Neural Network (RERNN) to achieve optimal power conversion, improved stability, and reduced total harmonic distortion (THD). Unlike traditional multilevel inverters (MLI), the MMI structure utilized in this work requires fewer power electronic components, reducing cost and complexity. The MAO algorithm optimally tunes control gain parameters offline, creating a dataset of optimal control signals, while the RERNN method predicts and applies real-time control signals, ensuring an efficient and stable power supply. The control strategy generates a smooth sinusoidal output by employing a staircase waveform approach and effectively mitigates external disturbances to maintain grid compliance. The proposed method is implemented in MATLAB/Simulink, and its performance is analyzed through comparisons with existing control techniques. Results demonstrate that the MAO-RERNN control strategy achieves superior power regulation, reduced THD, and enhanced robustness, making it a promising solution for next-generation PV-based inverter systems.
Personal mobile devices form an integral part of business activities today. Mobile devices, nevertheless, pose various security issues and data privacy threats, which require a close attention. The rational choice theory was utilized to examine the determinants of employees’ security behavior in relation to mobile device usage. Employees were postulated to rationally evaluate the costs and benefits of mobile security measures and decide on the option that is perceived to provide the best expected outcome. Twelve out of thirteen hypotheses examined in this study were found to be significant. We also hypothesized that demographics and work-related variables significantly affect employees’ mobile security practices, examined using ordinal logistic regression analysis. The findings indicate the efficacy of the rational choice theory in explaining mobile security behavior. Security inconvenience has been found to be a significant cost to information security measures. Moreover, the findings also showed the influence of gender, job function, past security experience, and perceived risk on the dependent variable. In conclusion, we would like to draw considerable attention to the contribution of security awareness programs and security training to good mobile security behaviors.
The increasing global demand for renewable energy has accelerated the adoption of grid-connected photovoltaic (PV) systems. However, conventional PV inverters often rely on transformers, which add to the system’s cost, size, and power losses. Transformerless inverter topologies have emerged as a promising alternative, offering improved efficiency, compact design, and lower costs. Despite these advantages, challenges such as high total harmonic distortion (THD), common mode voltage (CMV) issues, and neutral current imbalance must be addressed to ensure reliable grid integration. This research investigates a transformerless five-level neutral point clamped (NPC) inverter for grid-connected PV applications, aiming to overcome these challenges. The study focuses on analysing THD, mitigating CMV to enhance system reliability, and optimizing output voltage levels to meet grid standards. The proposed transformerless five-level NPC inverter, incorporating a coupled inductor, is controlled using Hexagonal Space Vector Modulation (HSVM) to improve performance. Additionally, the research evaluates neutral current behavior to ensure stability and compliance with grid codes. Simulation and experimental results validate the proposed system’s effectiveness under varying operating conditions, highlighting its potential as a high-efficiency, cost-effective solution for sustainable energy integration into the grid.