Thomas Huybrechts

Mr. Thomas Huybrechts

University of Antwerp - imec, IDLab - Faculty of Applied Engineering
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 November 2017
Verified
Book Chapter
Closed access
PDF file
Thomas HuybrechtsThomas Huybrechts
Thomas Huybrechts
YVYon Vanommeslaeghe
Yon Vanommeslaeghe
DBDries Blontrock
Dries Blontrock
GBGregory Van Barel
Gregory Van Barel
PHPeter Hellinckx
Peter Hellinckx

19 July 2019 in Future Internet
Verified
Journal Article
Open access
PDF file
SVSimon Vanneste
Simon Vanneste
JHJens de Hoog
Jens de Hoog
Thomas HuybrechtsThomas Huybrechts
Thomas Huybrechts
SBStig Bosmans
Stig Bosmans
REReinout Eyckerman
Reinout Eyckerman
PHPeter Hellinckx
Peter Hellinckx
The increase of Internet of Things devices and the rise of more computationally intense applications presents challenges for future Internet of Things architectures. We envision a future in which edge, fog, and cloud devices work together to execute future applications. Because the entire application cannot run on smaller edge or fog devices, we will need to split the application into smaller application components. These application components will send event messages to each other to create a single application from multiple application components. The execution location of the application components can be optimized to minimize the resource consumption. In this paper, we describe the Distributed Uniform Stream (DUST) framework that creates an abstraction between the application components and the middleware which is required to make the execution location transparent to the application component. We describe a real-world application that uses the DUST framework for platform transparency. Next to the DUST framework, we also describe the distributed DUST Coordinator, which will optimize the resource consumption by moving the application components to a different execution location. The coordinators will use an adapted version of the Contract Net Protocol to find local minima in resource consumption.

13 April 2023 in Energies
Verified
Journal Article
Open access
PDF file
SJStef Jacobs
Stef Jacobs
MPMargot De Pauw
Margot De Pauw
SMSenne Van Minnebruggen
Senne Van Minnebruggen
SGSara Ghane
Sara Ghane
Thomas HuybrechtsThomas Huybrechts
Thomas Huybrechts
IVIvan Verhaert
Ivan Verhaert
Collective heating systems have multiple end-users with time-varying, often different temperature demands. There are several concepts catering to this, e.g., multi-pipe networks and 2-pipe networks with or without decentralised booster systems. In this study, we focus on 2-pipe networks with a changing supply temperature by smart use of decentralised storage. By grouping high-temperature demands, the average supply temperature can be lowered during large parts of the day, which is beneficial for system efficiency. The actual energy-saving potential, however, can be case-specific and is expected to depend on design choices and implemented control strategies. In this paper, these dependencies are assessed and identified by implementing two optimised rule-based control strategies, providing in such a way a bench-mark for other control strategies. The results show that grouping yields energy savings of up to 36% at similar peak demand as with conventional control strategies. The energy-saving potential is greatest for large storage volumes and small networks, but large networks with large storage and proper control choices can also achieve around 30% energy savings. Moreover, high-temperature time can easily be reduced to less than 40% of the day, which could make space cooling without decentralised booster heat pumps possible, but this requires further research.

30 June 2021 in Energies
Verified
Journal Article
Open access
PDF file
Thomas HuybrechtsThomas Huybrechts
Thomas Huybrechts
PRPhilippe Reiter
Philippe Reiter
SMSiegfried Mercelis
Siegfried Mercelis
Jeroen FamaeyJeroen Famaey
Jeroen Famaey
SLSteven Latré
Steven Latré
PHPeter Hellinckx
Peter Hellinckx
Batteryless Internet-of-Things (IoT) devices need to schedule tasks on very limited energy budgets from intermittent energy harvesting. Creating an energy-aware scheduler allows the device to schedule tasks in an efficient manner to avoid power loss during execution. To achieve this, we need insight in the Worst-Case Energy Consumption (WCEC) of each schedulable task on the device. Different methodologies exist to determine or approximate the energy consumption. However, these approaches are computationally expensive and infeasible to perform on all type of devices; or are not accurate enough to acquire safe upper bounds. We propose a hybrid methodology that combines machine learning-based prediction on small code sections, called hybrid blocks, with static analysis to combine the predictions to a final upper bound estimation for the WCEC. In this paper, we present our work on an automated testbench for the Code Behaviour Framework (COBRA) that measures and profiles the upper bound energy consumption on the target device. Next, we use the upper bound measurements of the testbench to train eight different regression models that need to predict these upper bounds. The results show promising estimates for three regression models that could potentially be used for the methodology with additional tuning and training.

1 January 2019 in International Journal of Grid and Utility Computing
Verified
Journal Article
Closed access
Thomas HuybrechtsThomas Huybrechts
Thomas Huybrechts
YBYorick De Bock
Yorick De Bock
HLHaoxuan Li
Haoxuan Li
PHPeter Hellinckx
Peter Hellinckx
The Worst-Case Execution Time (WCET) of a task is an important value in real-time systems. This metric is used by the scheduler in order to schedule all tasks before their deadlines. However, the code and hardware architecture have a significant impact on the execution time and thus the WCET. Therefore, different analysis methodologies exist to determine the WCET, each with their own advantages and/or disadvantages. In this paper, a hybrid approach is proposed which combines the strengths of two common analysis techniques. The two-layer hybrid model splits the code of tasks into so-called basic blocks. The WCET can be determined by performing execution time measurements on each block and statically combining those results. The COBRA-HPA framework presented in this paper is developed to facilitate the creation of hybrid block models and automate the measurements/analysis process. Additionally, an elaborated discussion on the implementation and performance of the framework is given. In conclusion, the results of the COBRA-HPA framework show a significant reduction in analysis effort while keeping sound WCET predictions for the hybrid method compared to the static and measurement-based approach.

17 October 2018
Verified
Book Chapter
Closed access
PDF file
Thomas HuybrechtsThomas Huybrechts
Thomas Huybrechts
ACAmber Cassimon
Amber Cassimon
SMSiegfried Mercelis
Siegfried Mercelis
PHPeter Hellinckx
Peter Hellinckx
TCThomas Cassimon
Thomas Cassimon