Background/Objectives: To compare the five-year efficacy and safety of the 63 µm (XEN63) vs. 45 µm (XEN45) XEN® Gel Stent in patients with open-angle glaucoma (OAG). Methods: This retrospective matched (1:1) cohort study included adults with OAG who underwent standalone ab interno implantation of the XEN63 or the XEN45 between 2014 and 2021 at a tertiary referral center in Belgium. The primary outcome was IOP at five years. The secondary outcomes included surgical success, topical medication use, postoperative hypotony, complications and interventions. Results: Thirty eyes of 30 patients (15 XEN63 and 15 XEN45) were analyzed. The baseline characteristics were comparable. At five years, the mean IOP did not differ between the XEN63 and the XEN45 (11.5 vs. 11.0 mmHg; p = 0.54). The XEN63 demonstrated higher complete success rates than the XEN45 for both the IOP < 18 mmHg (10 vs. four eyes; p = 0.016) and <15 mmHg criteria (10 vs. three eyes; p = 0.003). The topical medication use was low and comparable (0.6 vs. 0.9 medications; p = 0.57). The numerical (13 vs. five eyes; p = 0.008) and symptomatic (six vs. two eyes; p = 0.2) hypotony were more frequent after the XEN63 implantation. The two eyes with XEN63 and none with XEN45 experienced clinically significant hypotony. The needling procedures and secondary glaucoma surgeries were more frequent after the XEN45. Conclusions: The XEN63 implantation was associated with higher long-term success rates and also with a higher incidence of early postoperative hypotony. These findings indicate a trade-off between efficacy and safety and suggest that careful patient selection and postoperative management are essential when considering larger lumen subconjunctival drainage devices.
Background/aims: Minimally invasive glaucoma surgery (MIGS) procedures are commonly combined with phacoemulsification to provide additional intraocular pressure (IOP) and/or topical medication reduction in patients with mild-to-moderate glaucoma. This study compared the 1-year efficacy and safety of excimer laser trabeculostomy (ELIOS) versus trabecular micro-bypass stenting (iStent inject and iStent inject W), both performed in combination with cataract surgery. Methods: This multicentre retrospective cohort study included patients undergoing combined phacoemulsification with either ELIOS (Phaco-ELIOS) or iStent implantation (Phaco-iStent) at three European centres between 2020 and 2025. The primary endpoint was IOP at 12 months postoperatively. Secondary endpoints included longitudinal IOP and medication use, surgical success, adverse events and the need for secondary glaucoma surgery. Longitudinal outcomes were analysed using multiple imputation. Results: A total of 343 eyes were included (164 Phaco-ELIOS and 179 Phaco-iStent), with 1-year follow-up available in 70%. Mean IOP decreased by 21.6% for Phaco-ELIOS and 20.7% for Phaco-iStent and remained stable through 12 months (p=0.74). Both procedures were associated with a similar reduction in postoperative topical glaucoma medications (0.56 vs 0.41; p=0.2). With Phaco-ELIOS, a higher proportion of eyes achieved medication reduction (46.4% vs 31.3%; p=0.02). Rates of adverse events and secondary glaucoma surgery were low and comparable in both groups. Conclusion: Phaco-ELIOS and Phaco-iStent provided comparable 1-year IOP reduction and overall safety. Phaco-ELIOS showed a greater number of patients with topical medication reduction, supporting its role as an effective combined MIGS option in patients undergoing cataract surgery.
Alzheimer’s disease (AD) pathology is increasingly recognized to manifest in the retina, offering a non-invasive window for early biomarker discovery. This proof-of-concept study investigated whether multimodal retinal imaging—hyperspectral imaging (HSI), optical coherence tomography (OCT), and color fundus photography (CFP)—can differentiate individuals with and without cerebral amyloid-beta (Aβ) pathology in 40 participants with PET-confirmed Aβ status (17 Aβ+, cognitively normal or with mild cognitive impairment; 23 Aβ− cognitively normal controls). HSI-derived gray-level co-occurrence matrix (GLCM) texture, OCT-derived ganglion cell–inner plexiform layer (GC-IPL) thickness, and CFP-derived vascular biomarkers (VBMs) were extracted, and logistic regression with leave-one-out cross-validation assessed classification performance per modality, alone and combined; the cohort was supplemented with AD dementia patients for exploratory trajectory analyses. HSI showed significantly lower GLCM correlation at 466 nm in Aβ+ participants, most pronounced in the inferior macula (p = 0.01, AUC = 0.72), and GC-IPL thickness confirmed an “inferior vulnerability zone.” Combining HSI and GC-IPL features yielded the best performance (AUC = 0.84; sensitivity = 0.82; specificity = 0.78), whereas vascular biomarkers contributed minimally. HSI features followed a non-monotonic trajectory across the AD continuum, decreasing in early Aβ+ stages and rising again in dementia. These findings demonstrate synergy between HSI and OCT for detecting retinal biomarkers of early-stage AD, supporting multimodal retinal imaging as a scalable screening approach warranting validation in larger, longitudinal cohorts.