Ágoston Vilmos Tordai

Mr. Ágoston Vilmos Tordai

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 October 2022 in Atmosphere
Verified
Journal Article
Open access
PDF file
JIJudit Ilona
Judit Ilona
BBBlanka Barok
Blanka Barok
ADAlexandru Dumitrescu
Alexandru Dumitrescu
Sorin ChevalSorin Cheval
Sorin Cheval
AGArun Gandhi
Arun Gandhi
TWTamás Dr. Weidinger
Tamás Dr. Weidinger
In this study, we consider the historical climatological time series available in the meteorological yearbooks of the Royal Hungarian Central Institute of Meteorology and Earth Magnetism, first published in 1871. Data quality improvement of historical data includes the homogenization process with outlier checks and data gap filling by applying the MASH software. We investigated 13 stations from the Carpathian Region having the most complete monthly temperature and precipitation time series for the period of 1871–1918 and 8 stations with fog observations (1886–1916). First, statistical tests were conducted to compare the main statistics of the historical datasets (1871–1918) with current data (1971–2020). The sources of the current data are the National Meteorological Administration of Romania and the European Climate Assessment & Dataset. The results show significant changes between the two periods. In the whole region, the mean temperature in the last five decades (1971–2020) was 0.77 °C higher than in 1871–1918. Changes in the frequency of foggy situations were also detected. On an annual scale, in the last 31-year period (1990–2020), the number of foggy days increased by 16.2 compared with 1886–1916. Even if some local trends can be detected in the historical periods (e.g., Cluj-Napoca), significant changes are much more characteristic in the recent period.

30 June 2025 in Atmosphere
Verified
Journal Article
Open access
PDF file
Bushra AtfehBushra Atfeh
Bushra Atfeh
Zoltán BarczaZoltán Barcza
Zoltán Barcza
VGVeronika Groma
Veronika Groma
ÁTÁgoston Vilmos Tordai
Ágoston Vilmos Tordai
RMRóbert Mészáros
Róbert Mészáros
In addition to the use of reference instruments, low-cost sensors (LCSs) are becoming increasingly popular for air quality monitoring both indoors and outdoors. These sensors provide real-time measurements of pollutants and facilitate better spatial and temporal coverage. However, these simpler devices are typically characterised by lower accuracy and precision and can be more sensitive to the environmental conditions than the reference instruments. It is therefore crucial to characterise the applicability and limitations of these instruments, for which a possible solution is their comparison with reference measurements in real-world conditions. To this end, a measurement campaign has been carried out to evaluate the PM2.5 readings of several low- and medium-cost air quality instruments of different types and categories (IQAir AirVisual Pro, TSI DustTrak™ II Aerosol Monitor 8532, Xiaomi Mijia Air Detector, and Xiaomi Smartmi PM2.5 Air Detector). A GRIMM EDM180 instrument was used as the reference. This campaign took place in Budapest, Hungary, from 12 November to 15 December 2020, during typically humid and foggy weather conditions, when the air pollution level was high due to the increased anthropogenic emissions, including wood burning for heating purposes. The results indicate that the individual sensors tracked the dynamics of PM2.5 concentration changes well (in a linear fashion), but the readings deviated from the reference measurements to varying degrees. Even though the AirVisual sensors performed generally well (0.85 < R2 < 0.93), the accuracy of the units showed inconsistency (13–93%) with typical overestimation, and their readings were significantly affected by elevated relative humidity levels and by temperature. Despite the overall overestimation of PM2.5 by the Xiaomi sensors, they also exhibited strong correlation coefficients with the reference, with R2 values of 0.88 and 0.94. TSI sensors exhibited slight underestimations with high explained variance (R2 = 0.93–0.94) and good accuracy. The results indicated that despite the inherent bias, the low-cost sensors are capable of capturing the temporal variability of PM2.5, thus providing relevant information. After simple and multiple linear regression-based correction, the low-cost sensors provided acceptable results. The results indicate that sensor data correction is a necessary prerequisite for the usability of the instruments. The ensemble method is a reasonable alternative for more accurate estimations of PM2.5.

1 January 2020
Verified
Book Chapter
Closed access
GGGandhi Arun Gandhi
Gandhi Arun Gandhi
ZAZénó Gyöngyösi András
Zénó Gyöngyösi András
ÁTÁgoston Vilmos Tordai
Ágoston Vilmos Tordai
PTPéter Torma
Péter Torma
ARAndrás Rehák
András Rehák
TWTamás Dr. Weidinger
Tamás Dr. Weidinger

23 August 2025 in Atmosphere
Verified
Journal Article
Open access
PDF file
RMRóbert Mészáros
Róbert Mészáros
Zoltán BarczaZoltán Barcza
Zoltán Barcza
Bushra AtfehBushra Atfeh
Bushra Atfeh
RHRoland Hollós
Roland Hollós
EKErzsébet Kristóf
Erzsébet Kristóf
VGVeronika Groma
Veronika Groma
During the last decades, development of novel low-cost sensors commercialized for indoor air quality measurements has gained interest. In this research, three AirVisual Pro air quality monitors were used to monitor PM2.5 and carbon dioxide concentrations in which two were installed indoors and one outdoors at two residential apartments in Central Europe (Budapest, Hungary). In our research, we present a methodology to support the evaluation of indoor sensors by utilizing official outdoor monitoring data, leveraging the fact that indoor spaces are frequently ventilated and thus influenced by outdoor conditions. We compared six-year measurement data (January 2017–December 2022) with outdoor concentrations provided by the Hungarian Air Quality Monitoring Network (HAQM). However, the well-known low spatial representativeness and high spatio-temporal variability of PM2.5 in city environments made this evaluation problematic, which needed to be addressed before comparison. Here we quantify the spatial heterogeneity of the HAQM PM2.5 data for a maximum of eight stations. Then, based on the carbon dioxide readings of the AirVisual Pro units, data filtering was performed for the AirVisual 1 and AirVisual 2 sensors located in indoor environments to identify ventilated periods (nearly 10,000 ventilated events) for the AirVisual 1 and AirVisual 2 sensors, respectively, for the comparison of indoor and outdoor PM2.5 concentrations. The AirVisual 3 sensor was placed in a garden storage, and the measurements taken there were considered outdoor values throughout. Finally, four heterogeneity criteria were set for the HAQM data to filter conditions that were assumed to be comparable with the indoor sensor data. The results indicate that the spatial heterogeneity was indeed detectable, and in approximately 50–60% of the cases, the readings could be considered as non-representative to single location comparison, but the results depend on the selected homogeneity criteria. The AirVisual and HAQM comparison indicated relatively low sensitivity to heterogeneity criteria, which is a promising result that can be exploited. AirVisual sensors generally overestimated PM2.5, but this bias could be corrected with a simple linear adjustment. Slopes changed across sensors (0.83–0.85 for AirVisual 1, 0.48–0.53 for AirVisual 2, and 0.70–0.73 for AirVisual 3), indicating general overestimation and correlations from moderate to high (R2 = 0.45–0.89) depending on the device. In contrast, when we compared the measurements only with data from the nearest reference station, we obtained a weaker match and slopes that did not match those calculated by taking into account homogeneity criteria. This research contributes to the proliferation of citizen science and supports the application of LCSs in indoor conditions.


18 March 2025
Verified
Conference Paper
Open access
BMBeáta Molnár
Beáta Molnár
TWTamás Dr. Weidinger
Tamás Dr. Weidinger
ÁBÁrpád Bordás
Árpád Bordás
ZNZsófia Nógrádi
Zsófia Nógrádi
RMRóbert Mészáros
Róbert Mészáros
PTPéter Tasnádi
Péter Tasnádi
One of the key challenges in high school physics and environmental education is teaching students the methods of scientific research and emphasizing its practical applications. An especially effective strategy involves engaging students in conducting simple environmental measurements, processing and analyzing the data, as well as comparing their results with those provided by professional monitoring stations.In this high school methodological research, we present the results of a student project developed to investigate classrooms air quality. The project was carried out in three different schools in Hungary, Serbia, and Slovakia. During the tests, we observed changes in the concentrations of carbon dioxide and PM2.5 particles throughout the day in classrooms and school gym using the AirVisual Pro Monitor with a 5-minute time resolution. The data was downloaded via a mobile application. During the measurements, we monitored the effects of various factors, such as ventilation and cleaning, on indoor air quality and tracked changes in CO2 concentration during lessons. The measured results were compared with data from nearby air pollution monitoring stations. The installation of outdoor AirVisual Pro Monitors is currently in progress.Our goal is to educate students about the health risks of air pollution and familiarize them with health-related limit values of various pollutants. Furthermore, an important objective is to help students understand how they can influence air quality in indoor environments. This joint project offers an opportunity to compare the environmental attitudes of students from different countries and to promote the spread of the “good practices” we have developed.