Knowledge of hydrodynamic behaviour is imperative for the water resource management and the sustainable development of basins. Hydraulic and hydrologic modelling are essential tools for the simulation of this behaviour. However, lack of basin assessment makes modelling input data scarce. This is the case for the Juqueriquere River basin, which comprises the major floodplains of the northern coastline of Sao Paulo State, Brazil. This region is susceptible to floods and is under pressure from real estate speculation, gas exploitation, and infrastructure development for port facilities. The purpose of this study was to estimate and calibrate Manning’s roughness coefficients of the Juqueriquere River basin, as they are mandatory data for hydraulic modelling. The estimation of Manning's n values was based on field observations. These data were inserted into the Hydrologic Engineering Center's River Analysis System (HEC-RAS) model for the calibration of the roughness coefficients in a trial and error process. The findings of this study proved that the estimation and calibration methods were efficient, with mean absolute deviations lower than 10% in the studied sections.
1 January 2019 in Operations Research Perspectives
First, this paper presents a thorough review of water quality data using a rainwater tank, categorizing the data as with and without sedimentation. Data are presented showing minimum, maximum, and mean values for the different parameters. The data measured from several sources reveal that water collected from the tank is much better than the water directly collected from the roof. In addition, to analyse the phenomena through a mathematical model, a hypothetical 5 kL rainwater tank with a 200 m2 roof was modelled with the MUSIC model. The simulations were compared with the measured water quality data from a rainwater tank in Melbourne. In general, we found that MUSIC’s simulations on the mean daily concentrations of total suspended solids (TSS) and total phosphorus (TP) are slight underestimations compared to the measured data from Melbourne. Further MUSIC simulations reveal that significant reductions in the daily maximum concentrations of TSS, TP, and total nitrogen (TN) are expected through a rainwater tank.
The Soil Conservation Service Curve Number (SCS-CN) model is widely used to estimate the watershed runoff. However, the model may result in inaccurate estimations when assuming a tabulated CN value and an initial abstraction (λ) of 0.20. Therefore, in this paper, we evaluated the suitability of four CN estimation methods for an urban watershed: Tabulated CN, National Engineering Handbook 4, Least Squares and Asymptotic Fitting. Also, the effect of ordering the data and different λ values (0.20 or 0.05) were analyzed. Our findings suggest that the transient approach of Asymptotic Fitting method, a variance from the original Asymptotic Fitting method, provides the best runoff estimations using rank ordered data and λ equal to 0.05 (R2 = 0.79, PBIAS = 0.01% and NSE = 0.78). It is to be noted that similar results were also obtained through a simple linear model.
For the analysis of rainwater tank outcomes, some researchers used monthly water balance model, which ignores an important factor such as overflow from the tank. Recently, to improve the accuracy of such analysis facilitated by the availability of daily rainfall data, many researchers started using daily timestep models. In the daily timestep models, the daily rainwater demand is deducted from the available storage, once in a day and there are debates on whether to apply that deduction at the beginning of the day or at the end of the day. Moreover, there is significant diurnal variation of water demand, which can not be accounted for in a daily timestep model. To overcome this, current study investigates an hourly timestep model considering hourly rainfall data and hourly variable rainwater demands. Hourly rainfall data was collected from the Australian Bureau of Meteorology for a raingauge station located in Melbourne. An earlier developed daily water balance model was converted to hourly scale incorporating hourly variable rainwater demands. Model simulated results for three distinct years (dry, average and wet) were compared with the results using a daily timestep model with the same data. Variations of water savings and overflow amounts are presented under four combinations of roof area and daily rainwater demand with tank sizes varying from 2500 L to 20,000 L. It is found that in all the selected years, the daily timestep model underestimated the annual water savings compared to the hourly timestep model and the highest difference was estimated to be 13,750 L for a smaller tank size connected with a bigger roof having higher rainwater demand.
23 March 2018 in International Journal of Environmental Research