Viacheslav V. Danilov

Dr. Viacheslav V. Danilov

Dept. of Inform. and Comm. Technologies, Pompeu Fabra University, Barcelona, Catalonia, Spain
+1
orcid
🔬 Data Alchemy: Crafting Beauty from Noise

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 April 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Viacheslav V. DanilovViacheslav V. Danilov
Viacheslav V. Danilov
KKKirill Yu. Klyshnikov
Kirill Yu. Klyshnikov
OGOlga M. Gerget
Olga M. Gerget
AKAnton G. Kutikhin
Anton G. Kutikhin
VGVladimir I. Ganyukov
Vladimir I. Ganyukov
Evgeny OvcharenkoEvgeny Ovcharenko
Evgeny Ovcharenko
Invasive coronary angiography remains the gold standard for diagnosing coronary artery disease, which may be complicated by both, patient-specific anatomy and image quality. Deep learning techniques aimed at detecting coronary artery stenoses may facilitate the diagnosis. However, previous studies have failed to achieve superior accuracy and performance for real-time labeling. Our study is aimed at confirming the feasibility of real-time coronary artery stenosis detection using deep learning methods. To reach this goal we trained and tested eight promising detectors based on different neural network architectures (MobileNet, ResNet-50, ResNet-101, Inception ResNet, NASNet) using clinical angiography data of 100 patients. Three neural networks have demonstrated superior results. The network based on Faster-RCNN Inception ResNet V2 is the most accurate and it achieved the mean Average Precision of 0.95, F1-score 0.96 and the slowest prediction rate of 3 fps on the validation subset. The relatively lightweight SSD MobileNet V2 network proved itself as the fastest one with a low mAP of 0.83, F1-score of 0.80 and a mean prediction rate of 38 fps. The model based on RFCN ResNet-101 V2 has demonstrated an optimal accuracy-to-speed ratio. Its mAP makes up 0.94, F1-score 0.96 while the prediction speed is 10 fps. The resultant performance-accuracy balance of the modern neural networks has confirmed the feasibility of real-time coronary artery stenosis detection supporting the decision-making process of the Heart Team interpreting coronary angiography findings.

27 July 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Viacheslav V. DanilovViacheslav V. Danilov
Viacheslav V. Danilov
DLDiana Litmanovich
Diana Litmanovich
APAlex Proutski
Alex Proutski
AKAlexander Kirpich
Alexander Kirpich
DNDato Nefaridze
Dato Nefaridze
YGYuriy Gankin
Yuriy Gankin
In this study, we propose a two-stage workflow used for the segmentation and scoring of lung diseases. The workflow inherits quantification, qualification, and visual assessment of lung diseases on X-ray images estimated by radiologists and clinicians. It requires the fulfillment of two core stages devoted to lung and disease segmentation as well as an additional post-processing stage devoted to scoring. The latter integrated block is utilized, mainly, for the estimation of segment scores and computes the overall severity score of a patient. The models of the proposed workflow were trained and tested on four publicly available X-ray datasets of COVID-19 patients and two X-ray datasets of patients with no pulmonary pathology. Based on a combined dataset consisting of 580 COVID-19 patients and 784 patients with no disorders, our best-performing algorithm is based on a combination of DeepLabV3 + , for lung segmentation, and MA-Net, for disease segmentation. The proposed algorithms’ mean absolute error (MAE) of 0.30 is significantly reduced in comparison to established COVID-19 algorithms; BS-net and COVID-Net-S, possessing MAEs of 2.52 and 1.83 respectively. Moreover, the proposed two-stage workflow was not only more accurate but also computationally efficient, it was approximately 11 times faster than the mentioned methods. In summary, we proposed an accurate, time-efficient, and versatile approach for segmentation and scoring of lung diseases illustrated for COVID-19 and with broader future applications for pneumonia, tuberculosis, pneumothorax, amongst others.

15 November 2022 in Robotics
Verified
Journal Article
Open access
PDF file
DKDmitrii Kolpashchikov
Dmitrii Kolpashchikov
OGOlga Gerget
Olga Gerget
Viacheslav V. DanilovViacheslav V. Danilov
Viacheslav V. Danilov
A continuum robot is a unique type of robots which move because of the elastic deformation of their bodies. The kinematics of such robots is typically described using constant curvature assumption. Such an assumption, however, does not completely describe the kinematics of a real-life continuum robot. As a result, variable curvature assumptions describe the kinematics of the continuum robot better, however, they are more complicated to formulate and work with. In particular, the existing methods of solving the inverse kinematics problem of multisection continuum robots with variable curvature suffer from a variety of deficiencies. Those deficiencies include complex matrix calculations, singularity problems, unscalability, and inability to find a numeric solution in some cases. In this work, we present FABRIKx: fast and reliable algorithm to solve the problem of inverse kinematics of the multisection continuum robot with variable curvature. In particular, to describe the variable curvature, we utilize a piecewise constant curvature assumption. The proposed algorithm combines both tangent and chord approaches to solve the inverse kinematics problem. The inverse kinematics of a single bending section of piecewise constant curvature is also described. To evaluate FABRIKx effectiveness, we compare it with the Jacobian-based and FABRIKc-based algorithms via simulation studies for different robots. The obtained results show that FABRIKx demonstrates a higher success rate and a lower solution time.

22 February 2022 in Nanomaterials
Verified
Journal Article
Open access
PDF file
MRMaria Rezvova
Maria Rezvova
PNPavel Nikishau
Pavel Nikishau
MMMiraslau I. Makarevich
Miraslau I. Makarevich
TGTatyana Glushkova
Tatyana Glushkova
KKKirill Yu Klyshnikov
Kirill Yu Klyshnikov
Evgeny OvcharenkoEvgeny Ovcharenko
Evgeny Ovcharenko
Nanocomposites based on poly(styrene-block-isobutylene-block-styrene) (SIBS) and single-walled carbon nanotubes (CNTs) were prepared and characterized in terms of tensile strength as well as bio- and hemocompatibility. It was shown that modification of CNTs using dodecylamine (DDA), featured by a long non-polar alkane chain, provided much better dispersion of nanotubes in SIBS as compared to unmodified CNTs. As a result of such modification, the tensile strength of the nanocomposite based on SIBS with low molecular weight (Mn = 40,000 g mol–1) containing 4% of functionalized CNTs was increased up to 5.51 ± 0.50 MPa in comparison with composites with unmodified CNTs (3.81 ± 0.11 MPa). However, the addition of CNTs had no significant effect on SIBS with high molecular weight (Mn~70,000 g mol−1) with ultimate tensile stress of pure polymer of 11.62 MPa and 14.45 MPa in case of its modification with 1 wt% of CNT-DDA. Enhanced biocompatibility of nanocomposites as compared to neat SIBS has been demonstrated in experiment with EA.hy 926 cells. However, the platelet aggregation observed at high CNT concentrations can cause thrombosis. Therefore, SIBS with higher molecular weight (Mn~70,000 g mol−1) reinforced by 1–2 wt% of CNTs is the most promising material for the development of cardiovascular implants such as heart valve prostheses.

15 September 2023 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
Viacheslav V. DanilovViacheslav V. Danilov
Viacheslav V. Danilov
KKKirill Y. Klyshnikov
Kirill Y. Klyshnikov
POPavel S. Onishenko
Pavel S. Onishenko
APAlex Proutski
Alex Proutski
YGYuriy Gankin
Yuriy Gankin
Evgeny OvcharenkoEvgeny Ovcharenko
Evgeny Ovcharenko
Majority of modern techniques for creating and optimizing the geometry of medical devices are based on a combination of computer-aided designs and the utility of the finite element method This approach, however, is limited by the number of geometries that can be investigated and by the time required for design optimization. To address this issue, we propose a generative design approach that combines machine learning (ML) methods and optimization algorithms. We evaluate eight different machine learning methods, including decision tree-based and boosting algorithms, neural networks, and ensembles. For optimal design, we investigate six state-of-the-art optimization algorithms, including Random Search, Tree-structured Parzen Estimator, CMA-ES-based algorithm, Nondominated Sorting Genetic Algorithm, Multiobjective Tree-structured Parzen Estimator, and Quasi-Monte Carlo Algorithm. In our study, we apply the proposed approach to study the generative design of a prosthetic heart valve (PHV). The design constraints of the prosthetic heart valve, including spatial requirements, materials, and manufacturing methods, are used as inputs, and the proposed approach produces a final design and a corresponding score to determine if the design is effective. Extensive testing leads to the conclusion that utilizing a combination of ensemble methods in conjunction with a Tree-structured Parzen Estimator or a Nondominated Sorting Genetic Algorithm is the most effective method in generating new designs with a relatively low error rate. Specifically, the Mean Absolute Percentage Error was found to be 11.8% and 10.2% for lumen and peak stress prediction respectively. Furthermore, it was observed that both optimization techniques result in design scores of approximately 95%. From both a scientific and applied perspective, this approach aims to select the most efficient geometry with given input parameters, which can then be prototyped and used for subsequent in vitro experiments. By proposing this approach, we believe it will replace or complement CAD-FEM-based modeling, thereby accelerating the design process and finding better designs within given constraints. The repository, which contains the essential components of the study, including curated source code, dataset, and trained models, is publicly available at https://github.com/ViacheslavDanilov/generative_design.

19 July 2021 in Frontiers in Cardiovascular Medicine
Verified
Journal Article
Open access
Viacheslav V. DanilovViacheslav V. Danilov
Viacheslav V. Danilov
KKKirill Yu. Klyshnikov
Kirill Yu. Klyshnikov
OGOlga M. Gerget
Olga M. Gerget
ISIgor P. Skirnevsky
Igor P. Skirnevsky
AKAnton G. Kutikhin
Anton G. Kutikhin
Evgeny OvcharenkoEvgeny Ovcharenko
Evgeny Ovcharenko
Currently, transcatheter aortic valve implantation (TAVI) represents the most efficient treatment option for patients with aortic stenosis, yet its clinical outcomes largely depend on the accuracy of valve positioning that is frequently complicated when routine imaging modalities are applied. Therefore, existing limitations of perioperative imaging underscore the need for the development of novel visual assistance systems enabling accurate procedures. In this paper, we propose an original multi-task learning-based algorithm for tracking the location of anatomical landmarks and labeling critical keypoints on both aortic valve and delivery system during TAVI. In order to optimize the speed and precision of labeling, we designed nine neural networks and then tested them to predict 11 keypoints of interest. These models were based on a variety of neural network architectures, namely MobileNet V2, ResNet V2, Inception V3, Inception ResNet V2 and EfficientNet B5. During training and validation, ResNet V2 and MobileNet V2 architectures showed the best prediction accuracy/time ratio, predicting keypoint labels and coordinates with 97/96% accuracy and 4.7/5.6% mean absolute error, respectively. Our study provides evidence that neural networks with these architectures are capable to perform real-time predictions of aortic valve and delivery system location, thereby contributing to the proper valve positioning during TAVI.