Víctor Murray

Dr. Víctor Murray

Memorial Sloan Kettering Cancer Center
+2
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 February 2010 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
CACarla Agurto
Carla Agurto
Víctor MurrayVíctor Murray
Víctor Murray
EBEduardo Barriga
Eduardo Barriga
SMSergio Murillo
Sergio Murillo
MPMarios Pattichis
Marios Pattichis
PSPeter Soliz
Peter Soliz
In this paper, we propose the use of multiscale amplitude-modulation-frequency-modulation (AM-FM) methods for discriminating between normal and pathological retinal images. The method presented in this paper is tested using standard images from the early treatment diabetic retinopathy study. We use 120 regions of 40 × 40 pixels containing four types of lesions commonly associated with diabetic retinopathy (DR) and two types of normal retinal regions that were manually selected by a trained analyst. The region types included microaneurysms, exudates, neovascularization on the retina, hemorrhages, normal retinal background, and normal vessels patterns. The cumulative distribution functions of the instantaneous amplitude, the instantaneous frequency magnitude, and the relative instantaneous frequency angle from multiple scales are used as texture feature vectors. We use distance metrics between the extracted feature vectors to measure interstructure similarity. Our results demonstrate a statistical differentiation of normal retinal structures and pathological lesions based on AM-FM features. We further demonstrate our AM-FM methodology by applying it to classification of retinal images from the MESSIDOR database. Overall, the proposed methodology shows significant capability for use in automatic DR screening.

9 November 2010 in IEEE Transactions on Information Technology in Biomedicine
Verified
Journal Article
Open access
CLChristos P Loizou
Christos P Loizou
Víctor MurrayVíctor Murray
Víctor Murray
MPM. S. Pattichis
M. S. Pattichis
ISI. Seimenis
I. Seimenis
MPM. Pantziaris
M. Pantziaris
Constantinos PattichisConstantinos Pattichis
Constantinos Pattichis
This study introduces the use of multiscale amplitude modulation-frequency modulation (AM-FM) texture analysis of multiple sclerosis (MS) using magnetic resonance (MR) images from brain. Clinically, there is interest in identifying potential associations between lesion texture and disease progression, and in relating texture features with relevant clinical indexes, such as the expanded disability status scale (EDSS). This longitudinal study explores the application of 2-D AM-FM analysis of brain white matter MS lesions to quantify and monitor disease load. To this end, MS lesions and normal-appearing white matter (NAWM) from MS patients, as well as normal white matter (NWM) from healthy volunteers, were segmented on transverse T2-weighted images obtained from serial brain MR imaging (MRI) scans (0 and 6-12 months). The instantaneous amplitude (IA), the magnitude of the instantaneous frequency (IF), and the IF angle were extracted from each segmented region at different scales. The findings suggest that AM-FM characteristics succeed in differentiating 1) between NWM and lesions; 2) between NAWM and lesions; and 3) between NWM and NAWM. A support vector machine (SVM) classifier succeeded in differentiating between patients that, two years after the initial MRI scan, acquired an EDSS ≤ 2 from those with EDSS >; 2 (correct classification rate = 86%). The best classification results were obtained from including the combination of the low-scale IA and IF magnitude with the medium-scale IA. The AM-FM features provide complementary information to classical texture analysis features like the gray-scale median, contrast, and coarseness. The findings of this study provide evidence that AM-FM features may have a potential role as surrogate markers of lesion load in MS.

1 July 2011 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
CACarla Agurto
Carla Agurto
EBE. Simon Barriga
E. Simon Barriga
Víctor MurrayVíctor Murray
Víctor Murray
SNSheila Nemeth
Sheila Nemeth
RCRobert Crammer
Robert Crammer
PSPeter Soliz
Peter Soliz
Purpose.: To describe and evaluate the performance of an algorithm that automatically classifies images with pathologic features commonly found in diabetic retinopathy (DR) and age-related macular degeneration (AMD). Methods.: Retinal digital photographs (N = 2247) of three fields of view (FOV) were obtained of the eyes of 822 patients at two centers: The Retina Institute of South Texas (RIST, San Antonio, TX) and The University of Texas Health Science Center San Antonio (UTHSCSA). Ground truth was provided for the presence of pathologic conditions, including microaneurysms, hemorrhages, exudates, neovascularization in the optic disc and elsewhere, drusen, abnormal pigmentation, and geographic atrophy. The algorithm was used to report on the presence or absence of disease. A detection threshold was applied to obtain different values of sensitivity and specificity with respect to ground truth and to construct a receiver operating characteristic (ROC) curve. Results.: The system achieved an average area under the ROC curve (AUC) of 0.89 for detection of DR and of 0.92 for detection of sight-threatening DR (STDR). With a fixed specificity of 0.50, the system's sensitivity ranged from 0.92 for all DR cases to 1.00 for clinically significant macular edema (CSME). Conclusions.: A computer-aided algorithm was trained to detect different types of pathologic retinal conditions. The cases of hard exudates within 1 disc diameter (DD) of the fovea (surrogate for CSME) were detected with very high accuracy (sensitivity = 1, specificity = 0.50), whereas mild nonproliferative DR was the most challenging condition (sensitivity= 0.92, specificity = 0.50). The algorithm was also tested on images with signs of AMD, achieving a performance of AUC of 0.84 (sensitivity = 0.94, specificity = 0.50).

12 January 2010 in IEEE Transactions on Image Processing
Verified
Journal Article
Closed access
Víctor MurrayVíctor Murray
Víctor Murray
PRPaul Rodriguez
Paul Rodriguez
MPMarios Pattichis
Marios Pattichis
We develop new multiscale amplitude-modulation frequency-modulation (AM-FM) demodulation methods for image processing. The approach is based on three basic ideas: (i) AM-FM demodulation using a new multiscale filterbank, (ii) new, accurate methods for instantaneous frequency (IF) estimation, and (iii) multiscale least squares AM-FM reconstructions. In particular, we introduce a variable-spacing local linear phase (VS-LLP) method for improved instantaneous frequency (IF) estimation and compare it to an extended quasilocal method and the quasi-eigen function approximation (QEA). It turns out that the new VS-LLP method is a generalization of the QEA method where we choose the best integer spacing between the samples to adapt as a function of frequency. We also introduce a new quasi-local method (QLM) for IF and IA estimation and discuss some of its advantages and limitations. The new IF estimation methods lead to significantly improved estimates. We present different multiscale decompositions to show that the proposed methods can be used to reconstruct and analyze general images.

2 January 2014 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
CACarla Agurto
Carla Agurto
Víctor MurrayVíctor Murray
Víctor Murray
HYHonggang Yu
Honggang Yu
JWJeffrey Wigdahl
Jeffrey Wigdahl
MPMarios Pattichis
Marios Pattichis
PSPeter Soliz
Peter Soliz
Pathologies that occur on or near the fovea, such as clinically significant macular edema (CSME), represent high risk for vision loss. The presence of exudates, lipid residues of serous leakage from damaged capillaries, has been associated with CSME, in particular if they are located one optic disc-diameter away from the fovea. In this paper, we present an automatic system to detect exudates in the macula. Our approach uses optimal thresholding of instantaneous amplitude (IA) components that are extracted from multiple frequency scales to generate candidate exudate regions. For each candidate region, we extract color, shape, and texture features that are used for classification. Classification is performed using partial least squares (PLS). We tested the performance of the system on two different databases of 652 and 400 images. The system achieved an area under the receiver operator characteristic curve (AUC) of 0.96 for the combination of both databases and an AUC of 0.97 for each of them when they were evaluated independently.

27 April 2023 in International Journal of Mining Science and Technology
Verified
Journal Article
Open access
DSDavid G. Shatwell
David G. Shatwell
Víctor MurrayVíctor Murray
Víctor Murray
ABAugusto Barton
Augusto Barton