Volker Enzmann

Prof. Dr. Volker Enzmann

Department of Ophthalmology, University Hospital of Bern, Bern, Switzerland
+1
orcid

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2009 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
UWUte E. K. Wolf-Schnurrbusch
Ute E. K. Wolf-Schnurrbusch
LCLala Ceklic
Lala Ceklic
CBChristian K. Brinkmann
Christian K. Brinkmann
MIMilko E. Iliev
Milko E. Iliev
MFManuel Frey
Manuel Frey
SWSebastian Wolf
Sebastian Wolf
Purpose. To compare central retinal thickness (CRT) measurements in healthy eyes by different commercially available OCT instruments and to compare the intersession reproducibility of such measurements. methods. Six different OCT instruments (Stratus OCT [Carl Zeiss Meditec, Inc. Dublin, CA], SOCT Copernicus [Reichert/Optopol Technology, Inc., Depew, NY], Spectral OCT/SLO [Opko/OTI, Inc., Miami, FL], RTVue-100 [Optovue Corp., Fremont, CA], Spectralis HRA+OCT [Heidelberg Engineering, Inc., Heidelberg, Germany], and Cirrus HD-OCT [Carl Zeiss Meditec, Inc.]) were used to assess CRT in both eyes of healthy subjects. Measurements were performed in two different sessions on the same day with each of the systems. From these measurements, the mean CRT was calculated. For the assessment of the intersession reproducibility of the instruments, we calculated the coefficient of the variation of test–retest variation. results. Twenty healthy subjects were included in the study. Compared with the Stratus OCT all spectral OCT instruments showed significantly higher CRTs. The Spectralis HRA+OCT and Cirrus HD-OCT showed similar CRT values but significantly higher values than did all other instruments. The coefficients of variation for repeated measurements was 3.33% for the Stratus OCT, 0.46% for the Spectralis HRA+OCT, 3.09% for the Cirrus HD-OCT, 2.23% for the OCT/SLO, 2.77% for the RTVue-100 OCT, and for the SOCT 3.5%, respectively. discussion. The six OCT systems provided different results for CRT. The measurements with the Stratus OCT showed the lowest thicknesses, whereas those with the Cirrus HD-OCT and Spectralis HRA+OCT yielded the highest ones. These discrepancies can be explained by the differences in the retinal segmentation algorithms used by the various OCT systems. Whereas the Spectralis HRA+OCT and Cirrus HD-OCT include the RPE layer in the retinal segmentation, the other instruments do not. The data imply that the different OCT systems cannot be used interchangeably for the measurement of macular thickness.

1 March 2006 in Experimental Eye Research
Verified
Journal Article
Closed access
VEVolker Enzmann
Volker Enzmann
BRBarry W. Row
Barry W. Row
YYYasuyuki Yamauchi
Yasuyuki Yamauchi
LKLeila Kheirandish
Leila Kheirandish
DGDavid Gozal
David Gozal
MMMaureen A. McCall
Maureen A. McCall

1 July 2008 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Closed access
PDF file
UWUte E. K. Wolf-Schnurrbusch
Ute E. K. Wolf-Schnurrbusch
VEVolker Enzmann
Volker Enzmann
CBChristian K. Brinkmann
Christian K. Brinkmann
SWSebastian Wolf
Sebastian Wolf
Purpose. To investigate the appearance of geographic atrophy in high-resolution optical coherence tomography (OCT) images, the fundus autofluorescence (FAF) pattern, and infrared images simultaneously recorded with a novel combined OCT-scanning laser ophthalmology (SLO) system. methods. Patients aged over 50 years with geographic atrophy secondary to dry age-related macular degeneration (ARMD) were assessed in a prospective cross-sectional study by means of simultaneous spectral OCT-SLO (Spectralis HRA+OCT; Heidelberg Engineering, Heidelberg, Germany). The integrity of the retinal layers was analyzed in the apparently normal areas, the junctional zone between the normal retina and the geographic atrophy, and the atrophic area. The presence and integrity of the external limiting membrane, the photoreceptor inner segments, the outer segments, and the retinal pigment epithelium were assessed. results. Fifty-two eyes of 52 patients (28 women, 24 men) aged 51 to 92 years were examined. Retinal layer alterations were documented, not only in atrophic zones, but also in junctional zones surrounding the geographic atrophy. Disintegration of the retinal layers began in the RPE and adjacent retinal layers, such as the photoreceptor inner and outer segments and external limiting membrane. conclusions. Novel imaging modalities will provide further valuable insight into ARMD pathogenesis. The key to understanding the morphologic change lies in in vivo depiction of retinal layers by spectral OCT technology in combination with other imaging modalities such as FAF.

22 February 2019 in Glia
Verified
Journal Article
Closed access
PDF file
FCFederica Maria Conedera
Federica Maria Conedera
APAna Maria Quintela Pousa
Ana Maria Quintela Pousa
NMNadia Mercader
Nadia Mercader
MTMarkus Tschopp
Markus Tschopp
VEVolker Enzmann
Volker Enzmann

1 May 2012 in Microvascular Research
Verified
Journal Article
Closed access
SSStefan Schlosser
Stefan Schlosser
CDCyrill Dennler
Cyrill Dennler
Riccardo SchweizerRiccardo Schweizer
Riccardo Schweizer
DEDaniel Eberli
Daniel Eberli
JSJens Stein
Jens Stein
JPJan A. Plock
Jan A. Plock

1 July 2015 in Translational Vision Science & Technology
Verified
Journal Article
Open access
PDF file
CDChantal Dysli
Chantal Dysli
VEVolker Enzmann
Volker Enzmann
RSRaphael Sznitman
Raphael Sznitman
MZMartin Sebastian Zinkernagel
Martin Sebastian Zinkernagel
Purpose: Quantification of retinal layers using automated segmentation of optical coherence tomography (OCT) images allows for longitudinal studies of retinal and neurological disorders in mice. The purpose of this study was to compare the performance of automated retinal layer segmentation algorithms with data from manual segmentation in mice using the Spectralis OCT. Methods: Spectral domain OCT images from 55 mice from three different mouse strains were analyzed in total. The OCT scans from 22 C57Bl/6, 22 BALBc, and 11 C3A.Cg-Pde6b+Prph2Rd2/J mice were automatically segmented using three commercially available automated retinal segmentation algorithms and compared to manual segmentation. Results: Fully automated segmentation performed well in mice and showed coefficients of variation (CV) of below 5% for the total retinal volume. However, all three automated segmentation algorithms yielded much thicker total retinal thickness values compared to manual segmentation data (P < 0.0001) due to segmentation errors in the basement membrane. Conclusions: Whereas the automated retinal segmentation algorithms performed well for the inner layers, the retinal pigmentation epithelium (RPE) was delineated within the sclera, leading to consistently thicker measurements of the photoreceptor layer and the total retina. Translational Relevance: The introduction of spectral domain OCT allows for accurate imaging of the mouse retina. Exact quantification of retinal layer thicknesses in mice is important to study layers of interest under various pathological conditions.