Wambley Adomako Baah

Mr. Wambley Adomako Baah

Hydraulic Structures Engineering, China Institute of Water Resources and Hydropower Research, Beijing, China
orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 June 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YWYangfeng Wu
Yangfeng Wu
JJJinsheng Jia
Jinsheng Jia
CZCuiying Zheng
Cuiying Zheng
BJBaozhen Jia
Baozhen Jia
YWYang Wang
Yang Wang
WBWambley Adomako Baah
Wambley Adomako Baah
Effective seepage control is crucial for maintaining the structural integrity of Cemented Sand, Gravel and Rock (CSGR) dams. Traditional methods using conventional concrete (CVC) or grout-enriched roller-compacted concrete (GERCC) are costly and disruptive. This paper presents a novel technique for constructing the protection and seepage control layer in Cemented Sand, Gravel and Rock (CSGR) dams. The method involves grouting and vibrating the loosened Cemented Sand, Gravel and Rock (CSGR) material to create vibrated grout-enriched Cemented Sand, Gravel and Rock, which performs similarly to concrete. A new surface water stop structure has also been developed for the structural joints. Laboratory tests revealed that Cemented Sand, Gravel and Rock (CSGR) with a vibrating–compacted (VC) value of 2–6 s and a compressive strength of 4 MPa meets design requirements for medium and low dams when the slurry addition rate is 8–12%. The T-shaped surface water stop demonstrated a bonding strength of over 1.8 MPa, withstanding a water pressure of 1.6 MPa. This method, integrated with dam body construction, reduces material costs by about 50% and eliminates construction interference. Specialized equipment for this technique has been developed, with a capacity of 12 m2/h. Implemented in the Minjiang Navigation and Hydropower Qianwei Project and Shaping I Hydropower Station, it has shown significant economic, environmental and safety benefits, promoting sustainable dam construction.

24 November 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
WBWambley Adomako Baah
Wambley Adomako Baah
JJJinsheng Jia
Jinsheng Jia
CZCuiying Zheng
Cuiying Zheng
YWYue Wang
Yue Wang
BJBaozhen Jia
Baozhen Jia
YWYangfeng Wu
Yangfeng Wu
A suitable range of paste and mortar margins (α and β) to enhance compressive strength in Rich-Mix cemented sand gravel and rock (CSGR) material for application in CSGRD construction is critical. SL 678-2014 recommends margins > 1, which are specifically designed to fill the voids within the fine and coarse aggregates with paste and mortar, respectively, while allowing some excess for workability. However, the optimum ranges of values after 1 are inadequately determined, often leading to high efforts and time-consuming trial mixes that are not economical. This study evaluates two datasets to identify the optimal ranges of α and β margins for compressive strength development in Rich-Mix CSGR, aiming to achieve the compressive strength class C18020, intended for use as cushion, protective, and seepage control layers in CSGRD. Using Pearson correlations, t-statistics, and p-values, the first dataset (7, 28, 90, and 180 days) showed weak correlations between paste margins and compressive strengths (coefficients 0.172 to 0.418, p-values > 0.05) and negligible relationships for mortar margins (coefficients −0.269 to 0.204, p-values > 0.05), affirming the contribution of other factors in the compressive strength development in CSGR. The second dataset (14, 28, 90, and 180 days) revealed significant positive correlations between paste margins and strengths at 14, 90, and 180 days (coefficients up to 0.850, p-values < 0.05). Mortar margins, however, negatively impacted strength (coefficients −0.544 to −0.628, p-values < 0.05), revealing the need to control the sand ratio. The optimal range of values was 1.05 ≤ α ≤ 1.09 and 1.15 ≤ β ≤ 1.25, with a water–binder ratio of 0.7~1.3, vibrating–compacted value (VC) of 2~8 s, and sand ratio of 18~35%. These findings highlight the significance of precise paste and mortar margin ranges in the compressive strength development of Rich-Mix CSGR.

2 January 2025 in Materials
Verified
Journal Article
Open access
PDF file
WBWambley Adomako Baah
Wambley Adomako Baah
JJJinsheng Jia
Jinsheng Jia
CZCuiying Zheng
Cuiying Zheng
BJBaozhen Jia
Baozhen Jia
YWYue Wang
Yue Wang
YWYangfeng Wu
Yangfeng Wu
Cemented Sand, Gravel, and Rock (CSGR) dams have traditionally used either Conventional Vibrated Concrete (CVC) or Grout-Enriched Roller Compacted Concrete (GERCC) for protective and seepage control layers in low- to medium-height dams. However, these methods are complex, prone to interference, and uneconomical due to significant differences in the expansion coefficient, elastic modulus, and hydration heat parameters among CSGR, CVC, and GERCC. This complexity complicates quality control during construction, leading to the development of Grout-Enriched Vibrated Cemented Sand, Gravel, and Rock (GECSGR) as an alternative. Despite its potential, GECSGR has limited use due to concerns about freeze–thaw resistance. This project addresses these concerns by developing an air-entrained GECSGR grout formulation and construction technique. The study follows a five-phase approach: mix proportioning of C1806 CSGR; optimization of the grout formulation; determination of grout addition rate; evaluation of small-scale lab samples of GECSGR; and field application. The results indicate that combining 8–12% of 223 kg/m3 cement grout with 2–2.23 kg/m3 of admixtures, mud content of 15%, a marsh time of 26–31 s. and a water/cement ratio of 0.5–0.6 with the C1806 parent CSGR mixture achieved a post-vibration in situ air content of 4–6%, excellent freeze–thaw resistance (F300: mass loss <5% or initial dynamic modulus ≥60%), and permeability resistance (W12: permeability coefficient of 0.13 × 10−10 m/s). The development of a 2-in-1 slurry addition and vibration equipment eliminated performance risks and enhanced efficiency in field applications, such as the conversion of the C1804 CSGR mixture into air-entrained GECSGR grade C9015W6F50 for the 2.76 km Qianwei protection dam. Economic analysis revealed that the unit cost of GECSGR production is 18.3% and 6.33% less than CVC and GERCC, respectively, marking a significant advancement in sustainable cement-based composite materials in the dam industry.