In a pilot-scale internal loop airlift reactor with a height of 5.5 m and a main column diameter of 0.484 m, the influence of three gas sparger structures (ladder distributor, tri-nozzle sparger and perforated plate) on the volumetric mass transfer coefficient kLa was investigated. It was found that the perforated plate produces the highest gas holdup difference and circulating liquid velocity between the riser and the downcomer. The perforated plate provides the most efficient mass transfer due to the more uniform gas distribution and higher circulating liquid velocity, followed by the ladder distributor and tri-nozzle spargers. Compared with the tri-nozzle sparger, the perforated plate increases the value of kLa by up to 16% at a superficial velocity of 0.15 m/s. Interestingly, the analysis of the liquid-phase mass transfer coefficient kL and specific area a with respect to gas velocity shows that the mass transfer rate is primarily controlled by a. By comparing the predictions of different mass transfer models, the slip velocity model based on penetration theory yields a satisfactory agreement with the experimental results within ±15% error. Meanwhile, empirical correlations regarding gas holdup and kLa were developed and were found to have good consistency with experimental values.
The hydrodynamic characteristics, mass transfer, and mixing performance of three different reactors, a bubble column reactor (BCR), a single-stage internal-loop airlift reactor (SSALR), and a four-stage internal-loop airlift reactor (FSALR), were investigated systematically through cold model experiments to explore the influence of draft tube configurations on the pilot-scale internal-loop airlift reactor (ILAR). The findings indicated that the BCR yielded a higher gas holdup and mass transfer coefficient due to its longer bubble residence time. Segmenting the draft tube improved the gas holdup in both the riser and downcomer, and the overall gas holdup in the downcomer increased by 9%. Compared with the SSALR, the mass transfer coefficient of the FSALR in the riser and downcomer increased by 10.2% and 9.3% on average, respectively. In addition, a higher liquid circulating velocity was obtained with the ILARs due to a higher gas holdup difference between the riser and the downcomer. Specifically, the liquid circulating velocity of the FSALR was 134.1% higher than that of the BCR and 15.8% higher than that of the SSALR. The mixing time of the ILARs was reduced due to more intense overall circulation. The mixing effect of the FSALR was the best. The mixing time was reduced by 70.2% and 51.3% compared with the BCR and SSALR for UG ranging from 4.0 cm/s to 9.1 cm/s, respectively. Empirical correlations were proposed for the gas holdup, liquid circulating velocity, mass transfer coefficient, and mixing time on the superficial gas velocity, and agreement with experimental data was satisfactory.