Wooseok Shin

Mr. Wooseok Shin

Korea University
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 September 2021 in JMIR Medical Informatics
Verified
Journal Article
Open access
SCSooho Choe
Sooho Choe
EPEunjeong Park
Eunjeong Park
WSWooseok Shin
Wooseok Shin
BKBonah Koo
Bonah Koo
DSDongjin Shin
Dongjin Shin
JKJeongmin Kim
Jeongmin Kim
Background: Intraoperative hypotension has an adverse impact on postoperative outcomes. However, it is difficult to predict and treat intraoperative hypotension in advance according to individual clinical parameters. Objective: The aim of this study was to develop a prediction model to forecast 5-minute intraoperative hypotension based on the weighted average ensemble of individual neural networks, utilizing the biosignals recorded during noncardiac surgery. Methods: In this retrospective observational study, arterial waveforms were recorded during noncardiac operations performed between August 2016 and December 2019, at Seoul National University Hospital, Seoul, South Korea. We analyzed the arterial waveforms from the big data in the VitalDB repository of electronic health records. We defined 2s hypotension as the moving average of arterial pressure under 65 mmHg for 2 seconds, and intraoperative hypotensive events were defined when the 2s hypotension lasted for at least 60 seconds. We developed an artificial intelligence–enabled process, named short-term event prediction in the operating room (STEP-OP), for predicting short-term intraoperative hypotension. Results: The study was performed on 18,813 subjects undergoing noncardiac surgeries. Deep-learning algorithms (convolutional neural network [CNN] and recurrent neural network [RNN]) using raw waveforms as input showed greater area under the precision-recall curve (AUPRC) scores (0.698, 95% CI 0.690-0.705 and 0.706, 95% CI 0.698-0.715, respectively) than that of the logistic regression algorithm (0.673, 95% CI 0.665-0.682). STEP-OP performed better and had greater AUPRC values than those of the RNN and CNN algorithms (0.716, 95% CI 0.708-0.723). Conclusions: We developed STEP-OP as a weighted average of deep-learning models. STEP-OP predicts intraoperative hypotension more accurately than the CNN, RNN, and logistic regression models. Trial Registration: ClinicalTrials.gov NCT02914444; https://clinicaltrials.gov/ct2/show/NCT02914444.

25 April 2023 in IEEE Transactions on Aerospace and Electronic Systems
Verified
Journal Article
Closed access
JKJin Sob Kim
Jin Sob Kim
HPHyun Joon Park
Hyun Joon Park
WSWooseok Shin
Wooseok Shin
DPDongil Park
Dongil Park
SHSung Won Han
Sung Won Han
The Automatic Identification System (AIS) has recorded near-real-time vessel monitoring data over the years, paving the way for data-driven maritime surveillance methods; concurrently, the data suffer from unrefined, reliability issues and irregular intervals. In this paper, we address the problem of vessel destination estimation by exploiting the global-scope AIS data. We propose a differentiated data-driven approach recasting a long sequence of port-to-port international vessel trajectories as a nested sequence structure. Based on spatial grids, this approach mitigates the spatio-temporal bias of AIS data while preserving the detailed resolution of the original. Further, we propose a novel deep learning architecture (WAY) that is designed to effectively process the reformulated trajectory and perform the long-term estimation of the vessel destination ahead of arrival with a horizon of days to weeks. WAY comprises a trajectory representation layer and channel-aggregative sequential processing (CASP) blocks. The representation layer produces the multi-channel vector sequence output based on each kinematic and non-kinematic feature collected from AIS data. Then CASP blocks include multi-headed channel- and self-attention architectures, where each processes aggregation and sequential information delivery respectively. Then, a task-specialized learning technique, Gradient Dropout (GD), is also suggested for adopting many-to-many training along the trajectory progression on single labels. The technique prevents a surge of biased feedback by blocking the gradient flow stochastically using the condition depending on the length of training samples. Experimental results on 5-year accumulated AIS data demonstrated the superiority of WAY with recasting AIS trajectory compared to conventional spatial grid-based approaches, regardless of the trajectory progression steps. Moreover, the data proved that adopting GD in a spatial grid-based approach leads to the performance gain. In addition, the possibilities of improvement and real-world application with WAY's expandability in multitask learning for the estimation of ETA was explored.

16 April 2024 in IEEE Signal Processing Letters
Verified
Journal Article
Closed access
HPHyun Joon Park
Hyun Joon Park
WSWooseok Shin
Wooseok Shin
JKJin Sob Kim
Jin Sob Kim
SHSung Won Han
Sung Won Han
To improve real-time speech enhancement (SE) while maintaining efficiency, researchers have adopted knowledge distillation (KD). However, when the same network type as the real-time SE student model is used as a teacher model, the performance of the teacher model can be unsatisfactory, thereby limiting the effectiveness of KD. To overcome this limitation, we propose cross-network non-causal knowledge distillation (CNNC-Distill). CNNC-Distill enables knowledge transfer between networks of different types, allowing the use of a teacher model with a different network type compared to the real-time SE student model. To maximize the KD effect, a non-real-time SE model unconstrained by causality conditions is adopted as the teacher model. CNNC-Distill transfers the non-causal knowledge of the non-real-time SE teacher model to a real-time SE student model using feature and output distillation. We also introduce a time-domain network, RT-SENet, used as the real-time SE student model. Results on the Valentini dataset show the efficiency of RT-SENet and the significant performance improvement achieved by CNNC-Distill.

17 February 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
WSWooseok Shin
Wooseok Shin
MLMin Seok Lee
Min Seok Lee
SHSung Won Han
Sung Won Han
Colonoscopy is an effective method for detecting polyps to prevent colon cancer. Existing studies have achieved satisfactory polyp detection performance by aggregating low-level boundary and high-level region information in convolutional neural networks (CNNs) for precise polyp segmentation in colonoscopy images. However, multi-level aggregation provides limited polyp segmentation owing to the distribution discrepancy that occurs when integrating different layer representations. To address this problem, previous studies have employed complementary low- and high- level representations. In contrast to existing methods, we focus on propagating complementary information such that the complementary low-level explicit boundary with abstracted high-level representations diminishes the discrepancy. This study proposes COMMA, which propagates complementary multi-level aggregation to reduce distribution discrepancies. COMMA comprises a complementary masking module (CMM) and a boundary propagation module (BPM) as a multi-decoder. The CMM masks the low-level boundary noises through the abstracted high-level representation and leverages the masked information at both levels. Similarly, the BPM incorporates the lowest- and highest-level representations to obtain explicit boundary information and propagates the boundary to the CMMs to improve polyp detection. CMMs can discriminate polyps more elaborately than prior CMMs based on boundary and complementary representations. Moreover, we propose a hybrid loss function to mitigate class imbalance and noisy annotations in polyp segmentation. To evaluate the COMMA performance, we conducted experiments on five benchmark datasets using five metrics. The results proved that the proposed network outperforms state-of-the-art methods in terms of all datasets. Specifically, COMMA improved mIoU performance by 0.043 on average for all datasets compared to the existing state-of-the-art methods.

24 June 2021 in JMIR Preprints
Verified
Preprint
Open access
SCSooho Choe
Sooho Choe
EPEunjeong Park
Eunjeong Park
WSWooseok Shin
Wooseok Shin
BKBonah Koo
Bonah Koo
DSDongjin Shin
Dongjin Shin
JKJeongmin Kim
Jeongmin Kim
BACKGROUND Intraoperative hypotension has an adverse impact on postoperative outcomes. However, it is difficult to predict and treat intraoperative hypotension in advance according to individual clinical parameters. OBJECTIVE The aim of this study was to develop a prediction model to forecast 5-minute intraoperative hypotension based on the weighted average ensemble of individual neural networks, utilizing the biosignals recorded during noncardiac surgery. METHODS In this retrospective observational study, arterial waveforms were recorded during noncardiac operations performed between August 2016 and December 2019, at Seoul National University Hospital, Seoul, South Korea. We analyzed the arterial waveforms from the big data in the VitalDB repository of electronic health records. We defined 2s hypotension as the moving average of arterial pressure under 65 mmHg for 2 seconds, and intraoperative hypotensive events were defined when the 2s hypotension lasted for at least 60 seconds. We developed an artificial intelligence–enabled process, named short-term event prediction in the operating room (STEP-OP), for predicting short-term intraoperative hypotension. RESULTS The study was performed on 18,813 subjects undergoing noncardiac surgeries. Deep-learning algorithms (convolutional neural network [CNN] and recurrent neural network [RNN]) using raw waveforms as input showed greater area under the precision-recall curve (AUPRC) scores (0.698, 95% CI 0.690-0.705 and 0.706, 95% CI 0.698-0.715, respectively) than that of the logistic regression algorithm (0.673, 95% CI 0.665-0.682). STEP-OP performed better and had greater AUPRC values than those of the RNN and CNN algorithms (0.716, 95% CI 0.708-0.723). CONCLUSIONS We developed STEP-OP as a weighted average of deep-learning models. STEP-OP predicts intraoperative hypotension more accurately than the CNN, RNN, and logistic regression models. CLINICALTRIAL ClinicalTrials.gov NCT02914444; https://clinicaltrials.gov/ct2/show/NCT02914444.