Wiktor Władysław Wolak

Dr. Wiktor Władysław Wolak

University of Zielona Góra, Zielona Góra, Lubuskie, Poland
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 March 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
KDKrzysztof K. Dudek
Krzysztof K. Dudek
WWWiktor Władysław Wolak
Wiktor Władysław Wolak
RGRuben Gatt
Ruben Gatt
JGJoseph N. Grima
Joseph N. Grima
In this work, through numerical studies, we show the possibility of designing composites in a form of magneto-mechanical metamaterials which are capable of exhibiting an enhanced impact resistance in comparison to their non-magnetic counterparts. We also show that it is possible to control the impact resistance of the system solely by means of the magnitude of the magnetic moment associated with magnetic inclusions inserted into the system as well as through the way how magnetic inclusions are distributed within the structure. The latter result is particularly interesting as in this work we show that through the appropriate distribution of magnetic inclusions it is possible to minimise the force that is being transferred to an object through the protective mechanical metamaterial. It is also suggested that the concept proposed in this work can be implemented in the case of already existing protective devices such as military-related protective devices and car bumpers in order to increase their efficiency.

18 March 2014 in European Journal of Cardio-Thoracic Surgery
Verified
Journal Article
Closed access
AAaron Casha
Aaron Casha
AMAlexander Manché
Alexander Manché
RGRuben Gatt
Ruben Gatt
WWWiktor Władysław Wolak
Wiktor Władysław Wolak
KDKrzysztof Dudek
Krzysztof Dudek
Joseph N. GrimaJoseph N. Grima
Joseph N. Grima
Primary spontaneous pneumothorax has long been explained as being without apparent cause. This paper deals with the effect of chest wall shape and explains how this may lead to the pathogenesis of primary spontaneous pneumothorax. Rib cage measurements were taken from chest radiographs in 12 male pneumothorax patients and 12 age-matched controls. Another group of 15 consecutive male thoracic computerised tomography (CT) were investigated using paramedian coronal and sagittal CT reconstructions to assess apical lung shape. A finite element analysis (FEA) model of a lung apex was constructed, including indentations for the first rib guided by CT scan data, to assess pleural stress. This model was tested using different anteroposterior diameter ratios, producing a range of thoracic indexes. The pneumothorax patients had a taller chest (P = 0.03), wider transversely (P = 0.009) and flatter (P = 0.03) when compared with controls, resulting in a low thoracic index. Prominent rib indentations were found anteriorly and posteriorly on the lung surface, especially on the first rib on CT. FEA of the lung revealed significantly higher stress (×5-×10) in the apex than in the rest of the lung. This was accentuated (×4) in low thoracic index chests, resulting in 20-fold higher stress levels in their apex. The FEA model demonstrates a 20-fold increase in pleural stress in the apex of chests with low thoracic index typical of spontaneous pneumothorax patients. Mild changes in thoracic index, as occurring in females or with aging, reduce pleural stress. Spontaneous pneumothorax occurring in young male adults may have a biomechanical cause.

26 November 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MDMirosław Roman Dudek
Mirosław Roman Dudek
KDK. K. Dudek
K. K. Dudek
WWWiktor Władysław Wolak
Wiktor Władysław Wolak
KWKrzysztof Wojciechowski
Krzysztof Wojciechowski
JGJ. N. Grima
J. N. Grima
Through the use of the Monte Carlo simulations utilising the mean-field approach, we show that a dense assembly of separated ultra-small magnetic nanoparticles embedded into a non-magnetic deformable matrix can be characterized by a large isothermal magnetic entropy change even upon applying a weak magnetic field with values much smaller than one Tesla. We also show that such entropy change may be very significant in the vicinity of the room temperature which effect normally requires an application of a strong external magnetic field. The deformable matrix chosen in this work as a host for magnetic nanoparticles adopts a thin film form with a large surface area to volume ratio. This in turn in combination with a strong magneto-volume coupling exhibited by this material allows us to show its suitability to be used in the case of a variety of applications utilising local cooling/heating such as future magnetic refrigerants.

17 July 2017 in Physica Status Solidi (RRL) – Rapid Research Letters
Verified
Journal Article
Closed access
PDF file
KDK. K. Dudek
K. K. Dudek
WWWiktor Władysław Wolak
Wiktor Władysław Wolak
MDMirosław Roman Dudek
Mirosław Roman Dudek
RCR. Caruana‐Gauci
R. Caruana‐Gauci
RGR. Gatt
R. Gatt
JGJ. N. Grima
J. N. Grima

2 September 2019 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
WWWiktor Władysław Wolak
Wiktor Władysław Wolak
AKAnatoly Boris Kolomeisky
Anatoly Boris Kolomeisky
MDMirosław Roman Dudek
Mirosław Roman Dudek
MMM Marć
M Marć
LNL Najder-Kozdrowska
L Najder-Kozdrowska
In this work, we investigate the possibility of using magnetic nanoparticles embedded into the silica to locally heat up the silica-water interface where the increase in temperature of nanoparticles is induced by an external radio-frequency magnetic field. Through the use of the theoretical model, it is shown that such the process leads to an increase in the total negative charge of the silica surface due to the deprotonation of silanol groups. It is also shown that the efficiency of such an electric charging process depends on the size of nanoparticles. Moreover, the optimal size of nanoparticles allowing for a maximum charging efficiency is determined. This observation may prove to be very important from the point of view of potential applications as it may allow to fine-tune chemical reactions on the silica surface. Some aspects of this work related to the magnetically heated nanoparticles were verified by the experiment.

8 April 2015 in Clinical Anatomy
Verified
Journal Article
Closed access
PDF file
AAaron Casha
Aaron Casha
LCLiberato Camilleri
Liberato Camilleri
AMAlexander Manché
Alexander Manché
RGRuben Gatt
Ruben Gatt
DADaphne Attard
Daphne Attard
Joseph N. GrimaJoseph N. Grima
Joseph N. Grima