Xiaodong Cheng

Dr. Xiaodong Cheng

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 May 2018 in IEEE Transactions on Control Systems Technology
Verified
Journal Article
Closed access
Michele CucuzzellaMichele Cucuzzella
Michele Cucuzzella
STSebastian Trip
Sebastian Trip
CPClaudio De Persis
Claudio De Persis
Xiaodong ChengXiaodong Cheng
Xiaodong Cheng
AFAntonella Ferrara
Antonella Ferrara
ASArjan Van der Schaft
Arjan Van der Schaft
In this paper, a novel distributed control algorithm for current sharing and voltage regulation in DC microgrids is proposed. The DC microgrid is composed of several distributed generation units, including buck converters and current loads. The considered model permits an arbitrary network topology and is affected by an unknown load demand and modeling uncertainties. The proposed control strategy exploits a communication network to achieve proportional current sharing using a consensus-like algorithm. Voltage regulation is achieved by constraining the system to a suitable manifold. Two robust control strategies of sliding mode type are developed to reach the desired manifold in a finite time. The proposed control scheme is formally analyzed, proving the achievement of proportional current sharing, while guaranteeing that the weighted average voltage of the microgrid is identical to the weighted average of the voltage references.

19 July 2018 in IEEE Control Systems Letters
Verified
Journal Article
Closed access
STSebastian Trip
Sebastian Trip
Michele CucuzzellaMichele Cucuzzella
Michele Cucuzzella
Xiaodong ChengXiaodong Cheng
Xiaodong Cheng
JSJacquelien Scherpen
Jacquelien Scherpen
In this letter we propose a new distributed control scheme, achieving current sharing and average voltage regulation in Direct Current (DC) microgrids. The considered DC microgrid is composed of several Distributed Generation Units (DGUs) interconnected through resistive-inductive power lines. Each DGU includes a generic energy source that supplies a local current load through a DC-DC buck converter. The proposed distributed control scheme achieves current sharing and average voltage regulation, independently of the initial condition of the controlled microgrid. Moreover, the proposed solution requires only measurements of the generated currents, and is independent of the microgrid parameters and the topology of the used communication network, facilitating Plug-and-Play capabilities. Global convergence to a desired steady state is proven and simulations indicate a good performance.

8 March 2017 in IEEE Transactions on Automatic Control
Verified
Journal Article
Closed access
Xiaodong ChengXiaodong Cheng
Xiaodong Cheng
YKYu Kawano
Yu Kawano
JSJacquelien M. A. Scherpen
Jacquelien M. A. Scherpen
This paper proposes a general framework for structure-preserving model reduction of a second-order network system based on graph clustering. In this approach, vertex dynamics are captured by the transfer functions from inputs to individual states, and the dissimilarities of vertices are quantified by the $\mathcal {H}_2$-norms of the transfer function discrepancies. A greedy hierarchical clustering algorithm is proposed to place those vertices with similar dynamics into same clusters. Then, the reduced-order model is generated by the Petrov–Galerkin method, where the projection is formed by the characteristic matrix of the resulting network clustering. It is shown that the simplified system preserves an interconnection structure, i.e., it can be again interpreted as a second-order system evolving over a reduced graph. Furthermore, this paper generalizes the definition of network controllability Gramian to second-order network systems. Based on it, we develop an efficient method to compute $\mathcal {H}_2$ -norms and derive the approximation error between the full-order and reduced-order models. Finally, the approach is illustrated by the example of a small-world network.

9 March 2020 in IEEE Transactions on Cybernetics
Verified
Journal Article
Closed access
NZNing Zhou
Ning Zhou
Xiaodong ChengXiaodong Cheng
Xiaodong Cheng
YXYuanqing Xia
Yuanqing Xia
YLYanjun Liu
Yanjun Liu
This article investigates the attitude stabilization problem of a rigid spacecraft with actuator saturation and failures. Two neural network-based control schemes are proposed using anti-saturation adaptive strategies. To satisfy the input constraint, we design two controllers in a saturation function structure. Taking into account the modeling uncertainties, external disturbances, and adverse effects from actuator faults and failures, the first anti-saturation adaptive controller is implemented based on radial basis function neural networks (RBFNNs) with a fixed-time terminal sliding mode (FTTSM) containing a tunable parameter. Then, we upgrade the proposed controller to a fully adaptive-gain anti-saturation version, in order to strengthen the robustness and adaptivity with respect to actuator faults and failures, unknown mass properties, and external disturbances. In the two schemes, all of the designed adaptive parameters are scalars, thus they only require light computational load and can avoid the redesign process of the controller during spacecraft operation. Finally, the feasibility of the proposed methods is illustrated via two numerical examples.

1 June 2019 in Automatica
Verified
Journal Article
Closed access
Xiaodong ChengXiaodong Cheng
Xiaodong Cheng
JSJacquelien M.A. Scherpen
Jacquelien M.A. Scherpen
BBBart Besselink
Bart Besselink

16 June 2018 in Advances in Computational Mathematics
Verified
Journal Article
Open access
PDF file
Xiaodong ChengXiaodong Cheng
Xiaodong Cheng
JSJacquelien M. A. Scherpen
Jacquelien M. A. Scherpen
This paper considers the network structure preserving model reduction of power networks with distributed controllers. The studied system and controller are modeled as second-order and first-order ordinary differential equations, which are coupled to a closed-loop model for analyzing the dissimilarities of the power units. By transfer functions, we characterize the behavior of each node (generator or load) in the power network and define a novel notion of dissimilarity between two nodes by the \(\mathcal {H}_{2}\)-norm of the transfer function deviation. Then, the reduction methodology is developed based on separately clustering the generators and loads according to their behavior dissimilarities. The characteristic matrix of the resulting clustering is adopted for the Galerkin projection to derive explicit reduced-order power models and controllers. Finally, we illustrate the proposed method by the IEEE 30-bus system example.