Xin'an Yuan

Prof. Xin'an Yuan

school of mechanical and electrical engineering, China University of Petroleum, East China, Qingdao, Shandong, China

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2021 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
Xin'an YuanXin'an Yuan
Xin'an Yuan
WLWei Li
Wei Li
GCGuoming Chen
Guoming Chen
XYXiaokang Yin
Xiaokang Yin
XLXiao Li
Xiao Li
JZJianming Zhao
Jianming Zhao
As the ocean engineering structure serves in the critical underwater environment, a variety of defects, such as cracks and corrosions, always cause damage to the structure. It is still a key challenge to identify and evaluate these defects accurately in the underwater environment. In this article, the visual and intelligent identification methods are presented for the inspection of defects in underwater structures using the alternating current field measurement (ACFM) technique. The current perturbation theory is developed to analyze the disturbed current field and the distorted magnetic field caused by defects. The gradient imaging algorithm is presented as an image preprocessing method to highlight the visual morphology of defects. The underwater intelligent ACFM system is set up. The experiments are carried out to verify the gradient imaging algorithm. The convolutional neural network (CNN) deep learning algorithm is presented to identify the grey-scale map samples preprocessed by the gradient imaging algorithm. The results show that the current perturbation theory clarifies the relationship between the characteristic signal and the morphology of various defects. The Bz image reflects the surface morphology of defects. The gradient imaging algorithm can achieve visual detection of defects. The single crack, the irregular crack, and the corrosion can be identified intelligently by the CNN deep learning algorithm. These defects can be evaluated accurately after classification.

28 October 2022 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
JZJianming Zhao
Jianming Zhao
WLWei Li
Wei Li
Xin'an YuanXin'an Yuan
Xin'an Yuan
XYXiaokang Yin
Xiaokang Yin
XLXiao Li
Xiao Li
JDJianxi Ding
Jianxi Ding
The alternating current field measurement (ACFM) technique has been widely used in the defect detection of metal structures. However, the identification and reconstruction of defects depend on human experience or simple empirical formulas, which leads to misjudgment of defects and large quantization errors. In this article, we propose an end-to-end physics-informed neural network for defect identification and 3-D reconstruction. The high-precision automatic detection system with a specially designed probe is established to detect defects in any direction. The faster RCNN network is used to identify and classify defects. The physics-informed Pix2Pix network is constructed to realize 3-D reconstruction of defects with different types. The results show that the established end-to-end physics-informed neural network can realize the identification and 3-D reconstruction of defects in which the mean average precision is 0.9982, the average length error of cracks is 0.9249 mm, the average depth error of cracks is 0.3402 mm, the average volume error of corrosion is 0.0667, and the average maximum depth error of corrosion is 0.3464 mm.

1 July 2018 in Measurement
Verified
Journal Article
Closed access
Xin'an YuanXin'an Yuan
Xin'an Yuan
WLWei Li
Wei Li
GCGuoming Chen
Guoming Chen
XYXiaokang Yin
Xiaokang Yin
JGJiuhao Ge
Jiuhao Ge
WMWeiping Ma
Weiping Ma

20 August 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
JZJianming Zhao
Jianming Zhao
WLWei Li
Wei Li
Xin'an YuanXin'an Yuan
Xin'an Yuan
XYXiaokang Yin
Xiaokang Yin
GCGuoming Chen
Guoming Chen
XLXiangyang Liu
Xiangyang Liu
As an important connection method between drill pipes, the thread is prone to fatigue cracks and stress corrosion cracks due to long-term exposure to complex forces and corrosive environments. The thread crack detection system of drill pipe based on altering current field measurement (ACFM) is proposed. The crack detection model of the drill pipe thread using ACFM is developed by the finite element software COMSOL. The distribution of the induced magnetic field above the thread is extracted. The relationships between the characteristic signal and the depth and angle of the crack are analyzed. The drill pipe thread detection probes and the detection system are established, and different types of cracks on two different specifications of threads are detected. The experimental results show that the detection system can achieve full coverage detection of the thread crest and root, and cracks at different angle can be identified effectively on the thread.

23 November 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
WLWei Li
Wei Li
ZWZhiren Wang
Zhiren Wang
XYXiaokang Yin
Xiaokang Yin
Xin'an YuanXin'an Yuan
Xin'an Yuan
HYHuimin Yang
Huimin Yang
XSXinyu Shao
Xinyu Shao
The circumferential 0-mode shear horizontal (CSH 0 ) guided waves have great advantages for the detection of cracks in pipelines due to the small attenuation of acoustic signals. However, the CSH 0 guided wave detection methods are confused by the signal mixing, low signal-to-noise ratio and poor quantitative accuracy of cracks. In this paper, the novel detection method which includes three circumferential uniformly distributed probes are proposed for quantitative detection of pipeline cracks. The signals received by two receiving probes constitute a couple of differential signals. A full physical field coupled finite element model is developed to study the effect of CSH guided wave-defect interactions. The differential signal enhancement algorithm can separate the crack signal from the overlapped signal, which greatly improves the accuracy of crack location. The characteristic coefficient method is introduced to improve the quantitative accuracy of the crack sizes. The localization and quantification methods are verified through experiments. The results show that the defect localization method proposed in this paper can improve the signal-to-noise ratio of the crack signal from -15 dB to 2.4 dB. The localization error of crack is less than 6.75%. The quantitative error of the crack sizes is less than 8.75% based on the characteristic coefficient method.

7 May 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
JZJianming Zhao
Jianming Zhao
WLWei Li
Wei Li
JGJiuhao Ge
Jiuhao Ge
Xin'an YuanXin'an Yuan
Xin'an Yuan
XYXiaokang Yin
Xiaokang Yin
JLJiang Li
Jiang Li
In recent years, with the exploitation of shale gas, the amount of coiled tubing has increased dramatically. Due to the harsh working environment, the wall thickness of the coiled tubing is easily thinned. In this paper, The coiled tubing wall thickness evaluation system is proposed based on the pulsed alternating current field measurement technique. The coiled tubing wall thickness evaluation model using pulsed alternating current field is developed by the finite element software COMSOL. The Bx signal is selected as the characteristic signal of thickness evaluation, and the relationship between characteristic signal and wall thickness is analyzed. According to the detection characteristics of the coiled tubing, probe and system for the wall thickness evaluation of the coiled tubing are designed and established. And the test experiment is carried out on different thicknesses of coiled tubing. The test results show that the detecting system can quantitatively evaluate the wall thickness of the coiled tubing accurately.