In industry, natural cracks usually exist in complex forms such as adjacent, colony, irregular, and crossing. Mere magnetic field is inadequate to accurately evaluate the complex cracks using eddy current testing. In this study, an improved eddy current imaging method using the signal of rotating eddy current testing (RECT) was proposed to reconstruct the surface profile of complex cracks. A transformation method was adopted to transform the signals of RECT into those under uniform eddy current testing at the desired orientation. The deconvolution of the transformed signals and square current dipole was carried out to obtain eddy current images at eight orientations around complex cracks. By accumulating the eddy current images, the surface profile of the complex cracks was reconstructed. Simulations and experiments were carried out to illustrate, validate, and test the proposed method. The results indicated that the obtained surface profiles were clearer than those obtained by the previous method using uniform eddy current testing. The improved method was effective for artificial complex slits and irregular stress corrosion crack colonies. Moreover, its performance was stable for the cracks with different angles and depths.
In recent years, with the exploitation of shale gas, the amount of coiled tubing has increased dramatically. Due to the harsh working environment, the wall thickness of the coiled tubing is easily thinned. In this paper, The coiled tubing wall thickness evaluation system is proposed based on the pulsed alternating current field measurement technique. The coiled tubing wall thickness evaluation model using pulsed alternating current field is developed by the finite element software COMSOL. The Bx signal is selected as the characteristic signal of thickness evaluation, and the relationship between characteristic signal and wall thickness is analyzed. According to the detection characteristics of the coiled tubing, probe and system for the wall thickness evaluation of the coiled tubing are designed and established. And the test experiment is carried out on different thicknesses of coiled tubing. The test results show that the detecting system can quantitatively evaluate the wall thickness of the coiled tubing accurately.