Yakub Fam

Dr. Yakub Fam

Technical University of Denmark
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 February 2020 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
XYXiaogang Yang
Xiaogang Yang
MKMaik Kahnt
Maik Kahnt
DBDennis Brückner
Dennis Brückner
ASAndreas Schropp
Andreas Schropp
YFYakub Fam
Yakub Fam
CSChristian G. Schroer
Christian G. Schroer
This paper presents a deep learning algorithm for tomographic reconstruction (GANrec). The algorithm uses a generative adversarial network (GAN) to solve the inverse of the Radon transform directly. It works for independent sinograms without additional training steps. The GAN has been developed to fit the input sinogram with the model sinogram generated from the predicted reconstruction. Good quality reconstructions can be obtained during the minimization of the fitting errors. The reconstruction is a self-training procedure based on the physics model, instead of on training data. The algorithm showed significant improvements in the reconstruction accuracy, especially for missing-wedge tomography acquired at less than 180° rotational range. It was also validated by reconstructing a missing-wedge X-ray ptychographic tomography (PXCT) data set of a macroporous zeolite particle, for which only 51 projections over 70° could be collected. The GANrec recovered the 3D pore structure with reasonable quality for further analysis. This reconstruction concept can work universally for most of the ill-posed inverse problems if the forward model is well defined, such as phase retrieval of in-line phase-contrast imaging.

30 July 2020 in Journal of Applied Crystallography
Verified
Journal Article
Open access
PDF file
ASAndreas Schropp
Andreas Schropp
RDRalph Döhrmann
Ralph Döhrmann
SBStephan Botta
Stephan Botta
DBDennis Brückner
Dennis Brückner
MKMaik Kahnt
Maik Kahnt
CSChristian G. Schroer
Christian G. Schroer
Ptychographic X-ray imaging at the highest spatial resolution requires an optimal experimental environment, providing a high coherent flux, excellent mechanical stability and a low background in the measured data. This requires, for example, a stable performance of all optical components along the entire beam path, high temperature stability, a robust sample and optics tracking system, and a scatter-free environment. This contribution summarizes the efforts along these lines to transform the nanoprobe station on beamline P06 (PETRA III) into the ptychographic nano-analytical microscope (PtyNAMi).

7 May 2018 in ChemCatChem
Verified
Journal Article
Open access
PDF file
YFYakub Fam
Yakub Fam
TSThomas L Sheppard
Thomas L Sheppard
ADAna Diaz
Ana Diaz
TSTorsten Scherer
Torsten Scherer
MHMirko Holler
Mirko Holler
Jan-Dierk GrunwaldtJan-Dierk Grunwaldt
Jan-Dierk Grunwaldt
Tomographic imaging of catalysts allows non‐invasive investigation of structural features and chemical properties by combining large fields of view, high spatial resolution, and the ability to probe multiple length scales. Three complementary nanotomography techniques, (i) electron tomography, (ii) focused ion beam—scanning electron microscopy, and (iii) synchrotron ptychographic X‐ray computed tomography, were applied to render the 3D structure of monolithic nanoporous gold doped with ceria, a catalytically active material with hierarchical porosity on the nm and μm scale. The resulting tomograms were used to directly measure volume fraction, surface area and pore size distribution, together with 3D pore network mapping. Each technique is critically assessed in terms of approximate spatial resolution, field of view, sample preparation and data processing requirements. Ptychographic X‐ray computed tomography produced 3D electron density maps with isotropic spatial resolution of 23 nm, the highest so far demonstrated for a catalyst material, and is highlighted as an emerging method with excellent potential in the field of catalysis.

26 September 2019 in Optica
Verified
Journal Article
Open access
PDF file
MKMaik Kahnt
Maik Kahnt
JBJohannes Becher
Johannes Becher
DBDennis Brückner
Dennis Brückner
YFYakub Fam
Yakub Fam
TSThomas L Sheppard
Thomas L Sheppard
CSChristian G. Schroer
Christian G. Schroer
Three-dimensional (3D) x-ray microscopy by ptychographic tomography requires elaborate numerical reconstructions. We describe a coupled ptychography-tomography reconstruction algorithm and apply it to an experimental ptychographic x-ray computed tomography data set of a catalyst particle. Compared to the traditional sequential algorithm, in which ptychographic projections are reconstructed to serve as input for subsequent tomographic reconstruction, the coupled ptychography-tomography algorithm reconstructs the 3D volume with higher spatial resolution over a larger field of view. Coupling the data from different projections improves the overall reconstruction, and the ptychographic sampling in individual projections can be coarsened beyond the point of overlap between neighboring scan points, still leading to stable reconstructions.

27 August 2019 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
YFYakub Fam
Yakub Fam
TSThomas L Sheppard
Thomas L Sheppard
JBJohannes Becher
Johannes Becher
DSDennis Scherhaufer
Dennis Scherhaufer
HLHeinz Lambach
Heinz Lambach
Jan-Dierk GrunwaldtJan-Dierk Grunwaldt
Jan-Dierk Grunwaldt
Two in situ `nanoreactors' for high-resolution imaging of catalysts have been designed and applied at the hard X-ray nanoprobe endstation at beamline P06 of the PETRA III synchrotron radiation source. The reactors house samples supported on commercial MEMS chips, and were applied for complementary hard X-ray ptychography (23 nm spatial resolution) and transmission electron microscopy, with additional X-ray fluorescence measurements. The reactors allow pressures of 100 kPa and temperatures of up to 1573 K, offering a wide range of conditions relevant for catalysis. Ptychographic tomography was demonstrated at limited tilting angles of at least ±35° within the reactors and ±65° on the naked sample holders. Two case studies were selected to demonstrate the functionality of the reactors: (i) annealing of hierarchical nanoporous gold up to 923 K under inert He environment and (ii) acquisition of a ptychographic projection series at ±35° of a hierarchically structured macroporous zeolite sample under ambient conditions. The reactors are shown to be a flexible and modular platform for in situ studies in catalysis and materials science which may be adapted for a range of sample and experiment types, opening new characterization pathways in correlative multimodal in situ analysis of functional materials at work. The cells will presently be made available for all interested users of beamline P06 at PETRA III.

23 September 2019 in The Journal of Physical Chemistry C
Verified
Journal Article
Closed access
JBJohannes Becher
Johannes Becher
TSThomas L Sheppard
Thomas L Sheppard
YFYakub Fam
Yakub Fam
SBSina Baier
Sina Baier
WWWu Wang
Wu Wang
Jan-Dierk GrunwaldtJan-Dierk Grunwaldt
Jan-Dierk Grunwaldt