Yoshihisa Ito

Mr. Yoshihisa Ito

Keio University
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 November 2020 in Small
Verified
Journal Article
Closed access
PDF file
YIYoshihisa Ito
Yoshihisa Ito
TOToshihisa Osaki
Toshihisa Osaki
KKKoki Kamiya
Koki Kamiya
TYTetsuya Yamada
Tetsuya Yamada
NMNorihisa Miki
Norihisa Miki
STShoji Takeuchi
Shoji Takeuchi

18 December 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
YIYoshihisa Ito
Yoshihisa Ito
YIYusuke Izawa
Yusuke Izawa
TOToshihisa Osaki
Toshihisa Osaki
KKKoki Kamiya
Koki Kamiya
NMNobuo Misawa
Nobuo Misawa
STShoji Takeuchi
Shoji Takeuchi
Lipid-bilayer devices have been studied for on-site sensors in the fields of diagnosis, food and environmental monitoring, and safety/security inspection. In this paper, we propose a lipid-bilayer-on-a-cup device for serial sample measurements using a pumpless solution exchange procedure. The device consists of a millimeter-scale cylindrical cup with vertical slits which is designed to steadily hold an aqueous solution and exchange the sample by simply fusing and splitting the solution with an external solution. The slit design was experimentally determined by the capabilities of both the retention and exchange of the solution. Using the optimized slit, a planar lipid bilayer was reconstituted with a nanopore protein at a microaperture allocated to the bottom of the cup, and the device was connected to a portable amplifier. The solution exchangeability was demonstrated by observing the dilution process of a blocker molecule of the nanopore dissolved in the cup. The pumpless solution exchange by the proposed cup-like device presents potential as a lipid-bilayer system for portable sensing applications.

1 June 2019
Verified
Conference Paper
Closed access
YIYoshihisa Ito
Yoshihisa Ito
TOToshihisa Osaki
Toshihisa Osaki
KKKoki Kamiya
Koki Kamiya
TYTetsuya Yamada
Tetsuya Yamada
NMNorihisa Miki
Norihisa Miki
STShoji Takeuchi
Shoji Takeuchi
This work designs and demonstrates the lipid bilayer-based ultra-sensitive biosensor capable of short-time detection in a quantitative manner, which is achieved by connecting multiple sensor elements in parallel.Artificial cell membranes with functional membrane proteins can form sensitive/selective biosensors. But the sensors suffer lengthy detection time at low concentration of analytes because the sensing mechanism relies on stochastic phenomena.In this work, we connected independent membrane sensors in parallel, where the ionic current through the multiple membranes was monitored by a single detector. With this format, the detection time is shortened based on the number of the array and the sensing can be quantitative. We developed a quad sensor assembling four membranes in parallel, and examined detection time of a single membrane sensor, the quad sensor, and four parallel quad-sensors. 1-GΩ resistor was installed in series with each membrane to avoid overload current caused by membrane rupture. The results showed significant improvement in the detection time and deviation by the parallelization, which promises quantitative monitoring with the stochastic sensor.

1 January 2018 in The Proceedings of the Symposium on Micro-Nano Science and Technology
Verified
Journal Article
Closed access
PDF file
YIYoshihisa Ito
Yoshihisa Ito
TOToshihisa Osaki
Toshihisa Osaki
KKKoki Kamiya
Koki Kamiya
TYTetsuya Yamada
Tetsuya Yamada
NMNorihisa Miki
Norihisa Miki
STShoji Takeuchi
Shoji Takeuchi
We developed a lipid bilayer array device for biological nanopore recordings. Our previous device using a droplet contact method had an advantage in good reproducibility, but a disadvantage in integration because of its large footprint. In this work, we proposed a device that is able to simultaneously form an array of lipid bilayers with a small footprint. The device consists of a rotating plate with 16 micropores and a fixed plate with 16 wells that hold aqueous droplets. Lipid bilayer membranes were formed at the micropores, and even if the bilayer is ruptured, the bilayer can be reconstructed by turning the rotating plate. We succeeded in observing the bilayer formed with the device and monitoring an ionic current signal by α-hemolysin incorporation.