Yuki Hashimoto

Prof. Yuki Hashimoto

Institute of Science Tokyo, Tokyo, Japan
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 April 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
YHYuki Hashimoto
Yuki Hashimoto
TITakako Ishihara
Takako Ishihara
KKKei Kuwabara
Kei Kuwabara
TATatsuro Amano
Tatsuro Amano
HTHiroyoshi Togo
Hiroyoshi Togo
Temperature elevation due to global warming increases the risks of dehydration, which can induce heat-related illness. Proper rehydration with appropriate amounts of water and electrolytes is essential to aid body fluid homeostasis. Wearable sweat sensors which can monitor both the sweat rate and sweat electrolyte concentration may be an effective tool for determining appropriate rehydration. Here, we developed a novel potentially wearable sensor that can monitor both the local sweat rate and sweat electrolyte concentration continuously. The new device includes a system with a short microfluidic pathway that guides the sweat appearing on the skin to a small space in the device to form a quantifiable droplet. The sweat rate is assessed from the time for the droplet to appear and droplet volume, while an integrated electric sensor detects the sodium chloride concentration in each sweat droplet. We demonstrated that this new device could record both the flow rates of artificial sweat and its sodium chloride concentration in ranges of human sweating with an accuracy within ±10%. This is equivalent to the accuracy of commercially available sweat rate meters and sweat ion sensors. The present study provides a new perspective for the design of wearable sensors that can continuously monitor sweat rates and sweat electrolyte concentrations for potential application to a healthcare device.

3 September 2021 in IEEE Access
Verified
Journal Article
Open access
AHAkimasa Hirata
Akimasa Hirata
TMTaiki Miyazawa
Taiki Miyazawa
RURyota Uematsu
Ryota Uematsu
SKSachiko Kodera
Sachiko Kodera
YHYuki Hashimoto
Yuki Hashimoto
HTHideto Tanaka
Hideto Tanaka
With increasing heat-wave frequency, the prevention and public awareness of heat-related illnesses has become an essential topic. In the standard for heat strain and stress, empirical guidelines to prevent excess core temperature rise above 1 °C have been prescribed for workers. However, measuring core temperature change in our daily life or working place is not straightforward. The estimation of core temperature from measured vital signals in a non-invasive manner is thus essential for the management of heat stress or strain. Here, we propose an estimation method for core temperature change by a simplified thermodynamics model with the measured heart rate and ambient conditions (temperature and relative humidity). Our proposed model is based on a two-layer two-compartment model with tuned parameters, which were derived from comparison between the computations using high-resolution anatomical human body model. Our model exhibited good agreement with the measured core temperature rise; the computed and measured core temperature rise for the naked trial were 0.54 °C and 0.53 °C, whereas those for the clothed trial were 0.70 °C, and 0.71 °C, respectively. Furthermore, our compartment model with vital data measured from a wearable device achieved good estimation in real time for field measurement in addition to computational replication with a previous study.

28 November 2022 in Sensors
Verified
Journal Article
Open access
PDF file
YHYuki Hashimoto
Yuki Hashimoto
里佐里江子 佐藤
里江子 佐藤
KTKazuhiko Takagahara
Kazuhiko Takagahara
TITakako Ishihara
Takako Ishihara
KWKento Watanabe
Kento Watanabe
HTHiroyoshi Togo
Hiroyoshi Togo
Real-time monitoring of heart rate is useful for monitoring workers. Wearable heart rate monitors worn on the upper body are less susceptible to artefacts caused by arm and wrist movements than popular wristband-type sensors using the photoplethysmography method. Therefore, they are considered suitable for stable and accurate measurement for various movements. In this study, we conducted an experiment to verify the accuracy of our developed and commercially available wearable heart rate monitor consisting of a smart shirt with bioelectrodes and a transmitter, assuming a real-world work environment with physical loads. An exercise protocol was designed to light to moderate intensity according to international standards because no standard exercise protocol for the validation simulating these works has been reported. This protocol includes worker-specific movements such as applying external vibration and lifting and lowering loads. In the experiment, we simultaneously measured the instantaneous heart rate with the above wearable device and a Holter monitor as a reference to evaluate mean absolute percentage error (MAPE). The MAPE was 0.92% or less for all exercise protocols conducted. This value indicates that the accuracy of the wearable device is high enough for use in real-world cases of physical load in light to moderate intensity tasks such as those in our experimental protocol. In addition, the experimental protocol and measurement data devised in this study can be used as a benchmark for other wearable heart rate monitors for use for similar purposes.

22 December 2014 in RSC Advances
Verified
Journal Article
Closed access
PDF file
KMKatsuo Mogi
Katsuo Mogi
YHYuki Hashimoto
Yuki Hashimoto
TTTakeshi Tsukahara
Takeshi Tsukahara
MTMotoki Terano
Motoki Terano
MYMasahiko Yoshino
Masahiko Yoshino
TYTakatoki Yamamoto
Takatoki Yamamoto
The photocured elastomer presented here provided extremely high replication accuracy due to its thermal shrinkage of less than 0.02%, compared to 2.91% in the heat-cured elastomer.

16 April 2025 in IEEE Access
Verified
Journal Article
Open access
YHYuki Hashimoto
Yuki Hashimoto
KNKota Noto
Kota Noto
STSoto Tada
Soto Tada
YNYoshifumi Nishida
Yoshifumi Nishida
Global warming and the associated increase in heat-waves have made the prevention of heatrelated illnesses such as heatstroke a critical global challenge. Monitoring physiological indicators such as core body temperature, heart rate, and sweat rate is beneficial for preventing excessive accumulation of heat stress and ensuring safe activities in hot environments. However, existing methods typically require multiple separate sensors, limiting their practicality for real-world applications. In this study, we describe the development of a compact and easy-to-use wearable multimodal sensor probe capable of simultaneously measuring the core body temperature, electrocardiogram, heart rate, and sweat rate. The prototype features an innovative design that integrates a heat flux probe for simultaneous measurement of the core body temperature and cardiac potentials with a computational model for estimating the sweat rate. Validation experiments were conducted with ten healthy adult men performing cycling exercises under controlled environmental conditions, with the accuracy of each measurement obtained from the prototype evaluated by comparison with reference values. The results showed root mean squared errors of 0.087°C for core body temperature and 131 g for total water loss, both surpassing the accuracy of previous studies. However, the prototype exhibited a tendency to overestimate the core body temperature and sweat rate during the exercise and post-exercise recovery phases compared to the resting condition before exercise. This was attributed to thermoregulatory responses, such as evaporative heat loss from sweating and increased skin blood flow, during exercise and recovery. Despite some remaining challenges in validation, this study represents a significant advancement in wearable sensor technology by offering a practical and comprehensive solution for real-time monitoring in hot environments. The proposed system has the potential to contribute to heat stress prevention in occupational, sports, and everyday settings.

6 February 2024 in Sensors and Actuators A: Physical
Verified
Journal Article
Open access
YHYuki Hashimoto
Yuki Hashimoto
STSoto Tada
Soto Tada
YNYoshifumi Nishida
Yoshifumi Nishida