Yuttana Kongjeen

Dr. Yuttana Kongjeen

Department of Electrical engineering, Intelligent Power System and Energy Research (IPER), Department of Electrical engineering, Faculty of Engineering and Technology, Rajamangala University of Technology Isan, Nakhon Ratchasima, Thailand
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 June 2018 in Energies
Verified
Journal Article
Open access
PDF file
Yuttana KongjeenYuttana Kongjeen
Yuttana Kongjeen
Krischonme N. BhumkittipichKrischonme N. Bhumkittipich
Krischonme N. Bhumkittipich
This paper proposes the impact of plug-in electric vehicles (PEVs) integrated into a power distribution system based on voltage-dependent control. The gasolinegate situation has many people turning to electric vehicles as a more environmentally friendly option, especially in smart community areas. The advantage of PEVs is modern vehicles that can use several types of fuel cells and batteries as energy sources. The proposed PEVs model was developed as a static load model in power distribution systems under balanced load conditions. The power flow analysis was determined by using certain parameters of the proposed electrical network. The main research objective was to determine the voltage magnitude profiles, the load voltage deviation, and total power losses of the electrical power system by using the new proposed methodology. Furthermore, it investigated the effects of the constant power load, the constant current load, the constant impedance load, and the plug-in electric vehicles load model. The IEEE 33 bus system was selected as the test system. The proposed methodology assigned the balanced load types in a steady state condition and used the new methodology to solve the power flow problem. The simulation results showed that increasing the plug-in electric vehicles load had an impact on the grids when compared with the other four load types. The lowest increased value for the plug-in electric vehicles load had an effect on the load voltage deviation (0.062), the total active power loss (120 kW) and the total reactive power loss (80 kVar), respectively. Therefore, this study verified that the load of PEVs can affect the electrical power system according to the time charging and charger position. Therefore, future work could examine the difference caused when PEVs are attached to the electrical power system by means of the conventional or complex load type.

1 March 2019 in Electric Power Systems Research
Verified
Journal Article
Closed access
Yuttana KongjeenYuttana Kongjeen
Yuttana Kongjeen
Krischonme N. BhumkittipichKrischonme N. Bhumkittipich
Krischonme N. Bhumkittipich
NMN. Mithulananthan
N. Mithulananthan
IAIraj Sadegh Amiri
Iraj Sadegh Amiri
PYP. Yupapin
P. Yupapin

14 September 2021 in Symmetry
Verified
Journal Article
Open access
PDF file
PPPrakasit Prabpal
Prakasit Prabpal
Yuttana KongjeenYuttana Kongjeen
Yuttana Kongjeen
Krischonme N. BhumkittipichKrischonme N. Bhumkittipich
Krischonme N. Bhumkittipich
We designed a battery energy storage system (BESS) based on the symmetrical concept where the required control is by the symmetrical technique known as volt/var control. The integration of BESS into the conventional distribution has significantly impacted energy consumption over the past year. Load demand probability was used to investigate optimal sizing and location of BESS in an electrical power system. The open electric power distribution system simulator (OpenDSS) was interfaced with MATLAB m-file scripts and presented by using time series analysis with load demand. The optimal BESS solution was adapted by using a genetic algorithm (GA) optimization technique and particle swarm optimization (PSO). The simulation results showed that the BESS was directly connected to the power grid with GA and PSO, and it was observed that BESS sizing also varied for these two values of 1539 kW and 1000 kW, respectively. The merit of those values is the power figure of the system, which is necessary for installation. Therefore, optimal sizing and location of the BESS are helpful to reduce the impact from the load demand to the total system loss and levelling of the energy demand from the power system network. The integration of the BESS can be applied to improve grid stability and store surplus energy very well. The grid increased the stability of the power system and reduced the impact from the large scale of BESS penetration.

9 December 2021 in Symmetry
Verified
Journal Article
Open access
PDF file
KYKulsomsup Yenchamchalit
Kulsomsup Yenchamchalit
Yuttana KongjeenYuttana Kongjeen
Yuttana Kongjeen
Prakasit PrabpalPrakasit Prabpal
Prakasit Prabpal
Krischonme N. BhumkittipichKrischonme N. Bhumkittipich
Krischonme N. Bhumkittipich
In this study, the concept of symmetry is introduced by finding the optimal state of a power system. An electric vehicle type load is present, where the supply stores’ electrical energy causes an imbalance in the system. The optimal conditions are related by adjusting the voltage of the bus location. The key variables are the load voltage deviation (LVD), the variation of the load and the power, and the sizing of the distributed photovoltaic (DPV), which are added to the system for power stability. Here, a method to optimize the fast-charging stations (FCSs) and DPV is presented using an optimization technique comparison. The system tests the distribution line according to the bus grouping in the IEEE 33 bus system. This research presents a hypothesis to solve the problem of the voltage level in the system using metaheuristic algorithms: the cuckoo search algorithm (CSA), genetic algorithm (GA), and simulated annealing algorithm (SAA) are used to determine the optimal position for DPV deployment in the grid with the FCSs. The LVD, computation time, and total power loss for each iteration are compared. The voltage dependence power flow is applied using the backward/forward sweep method (BFS). The LVD is applied to define the objective function of the optimization techniques. The simulation results show that the SAA showed the lowest mean computation time, followed by the GA and the CSA. A possible location of the DPV is bus no. 6 for FCSs with high penetration levels, and the best FCS locations can be found with the GA, with the best percentage of best hit counter on buses no. 2, 3, 13, 14, 28, 15, and 27. Therefore, FCSs can be managed and handled in optimal conditions, and this work supports future FCS expansion.
1

8 September 2016
Verified
Conference Paper
Closed access
Yuttana KongjeenYuttana Kongjeen
Yuttana Kongjeen
Krischonme N. BhumkittipichKrischonme N. Bhumkittipich
Krischonme N. Bhumkittipich
This paper proposes the modeling of electric vehicle(EV) loads for power flow analysis based on User Define Models (UDMs) in power system analysis toolbox (PSAT) programming, According to the development of EV technology especially motor controller and battery, the EV has totally designed and made for using in city area as small city cars. To study the performance of EV, this aims to present the model of EV loads for using to solve power flow analysis in the real power system. EV load is modeled as the function box equivalent on PSAT that can connect to the single line diagram of power system model. The IEEE 14 bus system is selected for simulating the performance of EV and charging station which compared between PQ load base case and EV load. The simulation result showed that the EV load was installed at bus No.14. The rated power of EV load was increased from 5.0 p.u. to 79 p.u. This proposed EV load model can be used to solve the power flow analysis with continuation power flow (CPF) method. The EV load model is directly effected to voltage stability margin when the EV load increased. This study can be verified that proposed EV load can use to study the EV load in the future works.

1 March 2018
Verified
Conference Paper
Closed access
KYKulsomsup Yenchamchalit
Kulsomsup Yenchamchalit
Yuttana KongjeenYuttana Kongjeen
Yuttana Kongjeen
Krischonme N. BhumkittipichKrischonme N. Bhumkittipich
Krischonme N. Bhumkittipich
NMNadarajah Mithulananthan
Nadarajah Mithulananthan
This paper had presented the optimal battery charging station for Plug-in Electric Vehicles (PEVs) in the electrical power system, by using the Particle Swarm Optimization technique (PSO). The PEVs are represented using the Voltage Source Converter (VSC) as the group of PEVs that were installed in the charging station. The electrical power system was analyzed in a steady state, by using the IEEE 30 bus test system. The installed PEVs site in the power system aimed to minimize system power loss. The results were shown that the optimal site is bus N0.30. The total power loss and percentage of power loss reduction were 0.0994 p.u. and 6.4%, respectively.