Krischonme N. Bhumkittipich

Prof. Dr. Krischonme N. Bhumkittipich

Electrical Engineering, Rajamangala University of Technology Thanyaburi (RMUTT), Pathum Thani, Thailand
orcid
Professor in Electrical Engineering

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2013 in Energy Procedia
Verified
Journal Article
Open access
Krischonme N. BhumkittipichKrischonme N. Bhumkittipich
Krischonme N. Bhumkittipich
WPWeerachai Phuangpornpitak
Weerachai Phuangpornpitak
This paper presents a new methodology using particle swarm optimization (PSO) for the placement of distributed generation (DG) in the radial distribution systems to reduce the power loss. Single DG placement is used to find the optimal DG location and its size which corresponding to the maximum loss reduction. The proposed method is tested on the 26-bus radial distribution system which modified from the Provincial Electricity Authority (PEA) distribution system. The total power is 8.49 MW and 5.97 MVAR and the power loss is 11.68kW and 26.08 kVAR. The load flow analysis on distribution use forward-backward sweep methodology. The simulation results show that PSO can obtain the maximum power loss reductions

17 November 2023 in Energies
Verified
Journal Article
Open access
PDF file
SDSaksit Deeum
Saksit Deeum
TCTossaporn Charoenchan
Tossaporn Charoenchan
Natin JanjamrajNatin Janjamraj
Natin Janjamraj
Sillawat RomphochaiSillawat Romphochai
Sillawat Romphochai
SBSergej Baum
Sergej Baum
Krischonme N. BhumkittipichKrischonme N. Bhumkittipich
Krischonme N. Bhumkittipich
This article presents the optimal placement of electric vehicle (EV) charging stations in an active integrated distribution grid with photovoltaic and battery energy storage systems (BESS), respectively. The increase in the population has enabled people to switch to EVs because the market price for gas-powered cars is shrinking. The fast spread of EVs depends solely on the rapid and coordinated growth of electric vehicle charging stations (EVCSs). Since EVCSs can cause power losses and voltage variations outside the permissible limits, their integration into the current distribution grid can be characterized by the growing penetration of randomly dispersed photovoltaic (PV) and battery energy storage (BESS) systems, which is complicated. This study used genetic algorithm (GA) optimization and load flow (accommodation of anticipated rise in the number of electric cars on the road) analysis with a forward and backward sweep methodology (FBSM) to locate, scale and optimize EVCSs from a distribution grid where distributed PV/BESSs are prevalent. Power optimization was demonstrated to be the objective issue, which included minimizing active and reactive power losses. To verify the proposed optimal objective solutions from the active distribution grid, an IEEE 33 bus distribution grid was considered for EVCSs’ optimization under the penetration of photovoltaic and BESS systems. MATLAB simulations for the integrated EVCS-PV-BESS system on the distribution grid for five different zones were performed using detection from zone 1 (ranging from 301.9726 kW to 203.3872 kW), reducing the power losses (accounting for 33%) in the system to a minimum level.

14 June 2018 in Energies
Verified
Journal Article
Open access
PDF file
Yuttana KongjeenYuttana Kongjeen
Yuttana Kongjeen
Krischonme N. BhumkittipichKrischonme N. Bhumkittipich
Krischonme N. Bhumkittipich
This paper proposes the impact of plug-in electric vehicles (PEVs) integrated into a power distribution system based on voltage-dependent control. The gasolinegate situation has many people turning to electric vehicles as a more environmentally friendly option, especially in smart community areas. The advantage of PEVs is modern vehicles that can use several types of fuel cells and batteries as energy sources. The proposed PEVs model was developed as a static load model in power distribution systems under balanced load conditions. The power flow analysis was determined by using certain parameters of the proposed electrical network. The main research objective was to determine the voltage magnitude profiles, the load voltage deviation, and total power losses of the electrical power system by using the new proposed methodology. Furthermore, it investigated the effects of the constant power load, the constant current load, the constant impedance load, and the plug-in electric vehicles load model. The IEEE 33 bus system was selected as the test system. The proposed methodology assigned the balanced load types in a steady state condition and used the new methodology to solve the power flow problem. The simulation results showed that increasing the plug-in electric vehicles load had an impact on the grids when compared with the other four load types. The lowest increased value for the plug-in electric vehicles load had an effect on the load voltage deviation (0.062), the total active power loss (120 kW) and the total reactive power loss (80 kVar), respectively. Therefore, this study verified that the load of PEVs can affect the electrical power system according to the time charging and charger position. Therefore, future work could examine the difference caused when PEVs are attached to the electrical power system by means of the conventional or complex load type.

1 March 2019 in Electric Power Systems Research
Verified
Journal Article
Closed access
Yuttana KongjeenYuttana Kongjeen
Yuttana Kongjeen
Krischonme N. BhumkittipichKrischonme N. Bhumkittipich
Krischonme N. Bhumkittipich
NMN. Mithulananthan
N. Mithulananthan
IAIraj Sadegh Amiri
Iraj Sadegh Amiri
PYP. Yupapin
P. Yupapin

14 September 2021 in Symmetry
Verified
Journal Article
Open access
PDF file
PPPrakasit Prabpal
Prakasit Prabpal
Yuttana KongjeenYuttana Kongjeen
Yuttana Kongjeen
Krischonme N. BhumkittipichKrischonme N. Bhumkittipich
Krischonme N. Bhumkittipich
We designed a battery energy storage system (BESS) based on the symmetrical concept where the required control is by the symmetrical technique known as volt/var control. The integration of BESS into the conventional distribution has significantly impacted energy consumption over the past year. Load demand probability was used to investigate optimal sizing and location of BESS in an electrical power system. The open electric power distribution system simulator (OpenDSS) was interfaced with MATLAB m-file scripts and presented by using time series analysis with load demand. The optimal BESS solution was adapted by using a genetic algorithm (GA) optimization technique and particle swarm optimization (PSO). The simulation results showed that the BESS was directly connected to the power grid with GA and PSO, and it was observed that BESS sizing also varied for these two values of 1539 kW and 1000 kW, respectively. The merit of those values is the power figure of the system, which is necessary for installation. Therefore, optimal sizing and location of the BESS are helpful to reduce the impact from the load demand to the total system loss and levelling of the energy demand from the power system network. The integration of the BESS can be applied to improve grid stability and store surplus energy very well. The grid increased the stability of the power system and reduced the impact from the large scale of BESS penetration.

9 December 2021 in Symmetry
Verified
Journal Article
Open access
PDF file
KYKulsomsup Yenchamchalit
Kulsomsup Yenchamchalit
Yuttana KongjeenYuttana Kongjeen
Yuttana Kongjeen
Prakasit PrabpalPrakasit Prabpal
Prakasit Prabpal
Krischonme N. BhumkittipichKrischonme N. Bhumkittipich
Krischonme N. Bhumkittipich
In this study, the concept of symmetry is introduced by finding the optimal state of a power system. An electric vehicle type load is present, where the supply stores’ electrical energy causes an imbalance in the system. The optimal conditions are related by adjusting the voltage of the bus location. The key variables are the load voltage deviation (LVD), the variation of the load and the power, and the sizing of the distributed photovoltaic (DPV), which are added to the system for power stability. Here, a method to optimize the fast-charging stations (FCSs) and DPV is presented using an optimization technique comparison. The system tests the distribution line according to the bus grouping in the IEEE 33 bus system. This research presents a hypothesis to solve the problem of the voltage level in the system using metaheuristic algorithms: the cuckoo search algorithm (CSA), genetic algorithm (GA), and simulated annealing algorithm (SAA) are used to determine the optimal position for DPV deployment in the grid with the FCSs. The LVD, computation time, and total power loss for each iteration are compared. The voltage dependence power flow is applied using the backward/forward sweep method (BFS). The LVD is applied to define the objective function of the optimization techniques. The simulation results show that the SAA showed the lowest mean computation time, followed by the GA and the CSA. A possible location of the DPV is bus no. 6 for FCSs with high penetration levels, and the best FCS locations can be found with the GA, with the best percentage of best hit counter on buses no. 2, 3, 13, 14, 28, 15, and 27. Therefore, FCSs can be managed and handled in optimal conditions, and this work supports future FCS expansion.
1