Zaid Farooq Pitafi

Dr. Zaid Farooq Pitafi

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 January 2025 in IEEE Internet of Things Journal
Verified
Journal Article
Closed access
ZPZaid Farooq Pitafi
Zaid Farooq Pitafi
YSYingjian Song
Yingjian Song
Zaipeng XieZaipeng Xie
Zaipeng Xie
BBBenjamin Brainard
Benjamin Brainard
WenZhan SongWenZhan Song
WenZhan Song
Monitoring vital signs such as Heart Rate (HR) and Respiratory Rate (RR) is critical for veterinary medicine. The existing contact based systems are difficult to use on animals for longer periods as they may cause movement restriction. Contactless solutions have recently gained more popularity due to their ease-of-use. However, there are very few validated systems for animals. In this study, we propose a contactless vital signs monitoring system, CageDot for animals. Our system provides continuous real-time monitoring of HR and RR during hospitalization. The CageDot is placed under the animal cage and detects the heart vibrations using a geophone sensor. The CageDot also has a signal quality control algorithm to address the problem of obtaining high-quality cardiac data in real-life noisy environments such as hospitals. Compared to the existing works that use controlled environments, this is especially significant. The algorithm includes several steps that include background noise/movement removal, subject movement detection, heartbeat extraction and vital signs estimation. The experimental results on 16 hospitalized dogs and cats show that this system can achieve high accuracy for vital signs monitoring with a Mean Absolute Error (MAE) of 4.71 for Heart Rate (3.8 percent error rate) and 1.28 (8 percent error rate) for Respiratory Rate.

9 June 2025 in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
Verified
Journal Article
Open access
YSYingjian Song
Yingjian Song
HXHaotian Xiang
Haotian Xiang
ZZZixuan Zeng
Zixuan Zeng
JCJiayu Chen
Jiayu Chen
YZYida Zhang
Yida Zhang
WenZhan SongWenZhan Song
WenZhan Song
In-bed postures offer valuable information about an individual's sleep quality and overall health conditions, particularly for patients with sleep apnea. However, current in-bed posture classification systems lack privacy-friendly and easy-to-install options. Furthermore, existing solutions do not consider variations between patients and are typically trained only once, neglecting the utilization of time consistency and unlabeled data from new patients. To address these limitations, this paper builds on a seismic sensor to introduce a novel sleep posture framework, which comprises two main components, namely, the Multi-Granularity Supervised Contrastive Learning (MGSCL) module and the ensemble Online Adaptation (oa) module. Unlike most existing contrastive learning frameworks that operate at the sample level, MGSCL leverages multi-granular information, operating not only at the sample level but also at the group level. The oa module enables the model to adapt to new patient data while ensuring time consistency in sleep posture predictions. Additionally, it quantifies model uncertainty to generate weighted predictions, further enhancing performance. Evaluated on a dataset of 100 patients collected at a clinical research center, MGSCLoa achieved an average accuracy of 91.67% and an average F1 score of 91.53% with only 40 seconds of labeled data per posture. In a Phase 2 evaluation with 11 participants over 13 nights in home settings, the framework reached an average accuracy of 85.37% and a weighted F1 score of 83.59% using just 3 minutes of labeled data per common posture for each participant. These results underscore the potential of seismic sensor-based in-bed posture classification for assessing sleep quality and related health conditions.

4 November 2024
Verified
Conference Paper
Open access
YSYingjian Song
Yingjian Song
ZPZaid Farooq Pitafi
Zaid Farooq Pitafi
ZZZixuan Zeng
Zixuan Zeng
JCJiayu Chen
Jiayu Chen
YZYida Zhang
Yida Zhang
WenZhan SongWenZhan Song
WenZhan Song
Health monitoring is essential for both humans and animals in daily life. While numerous health monitoring systems have been developed, the majority are designed exclusively for either humans or animals, and most require direct physical contact. We have developed BedDot, a contactless health monitoring system for both humans and animals using a seismic sensor. BedDot can be deployed in various environments, such as bed and seat settings for humans, as well as in cages for animals, to monitor occupancy, heart rate (HR), respiratory rate (RR), and blood pressure (BP). Our system demonstrates high accuracy in the clinical experiments of 150 patients and 16 dogs and cats.

22 August 2024 in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
Verified
Journal Article
Open access
YSYingjian Song
Yingjian Song
ZPZaid Farooq Pitafi
Zaid Farooq Pitafi
FDFei Dou
Fei Dou
JSJin Sun
Jin Sun
XZXiang Zhang
Xiang Zhang
WenZhan SongWenZhan Song
WenZhan Song
In automated sleep monitoring systems, bed occupancy detection is the foundation or the first step before other downstream tasks, such as inferring sleep activities and vital signs. The existing methods do not generalize well to real-world environments due to single environment settings and rely on threshold-based approaches. Manually selecting thresholds requires observing a large amount of data and may not yield optimal results. In contrast, acquiring extensive labeled sensory data poses significant challenges regarding cost and time. Hence, developing models capable of generalizing across diverse environments with limited data is imperative. This paper introduces SeismoDot, which consists of a self-supervised learning module and a spectral-temporal feature fusion module for bed occupancy detection. Unlike conventional methods that require separate pre-training and fine-tuning, our self-supervised learning module is co-optimized with the primary target task, which directs learned representations toward a task-relevant embedding space while expanding the feature space. The proposed feature fusion module enables the simultaneous exploitation of temporal and spectral features, enhancing the diversity of information from both domains. By combining these techniques, SeismoDot expands the diversity of embedding space for both the temporal and spectral domains to enhance its generalizability across different environments. SeismoDot not only achieves high accuracy (98.49%) and F1 scores (98.08%) across 13 diverse environments, but it also maintains high performance (97.01% accuracy and 96.54% F1 score) even when trained with just 20% (4 days) of the total data. This demonstrates its exceptional ability to generalize across various environmental settings, even with limited data availability.

2 December 2025 in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
Verified
Journal Article
Open access
JCJiayu Chen
Jiayu Chen
YSYingjian Song
Yingjian Song
YZYida Zhang
Yida Zhang
ZZZixuan Zeng
Zixuan Zeng
XZXiang Zhang
Xiang Zhang
WenZhan SongWenZhan Song
WenZhan Song
Cardiovascular diseases (CVDs) remain a major global health challenge, highlighting the urgent need for advanced cardiac monitoring solutions. Continuous, contactless cardiac monitoring using seismic sensors enables comfortable, privacy-preserving assessments by capturing subtle heart vibrations. However, these systems are highly susceptible to diverse noise sources. Existing denoising methods struggle to handle the complex noise in cardiac seismic signals and poorly leverage the abundant unlabeled data. To address these challenges, we propose SelfDenoiser, a self-supervised framework for denoising and reconstructing cardiac seismic signals using unlabeled data. During training, SelfDenoiser first selects clean segments from the unlabeled pool, then injects adaptive noise into each segment to simulate shared, hard-to-remove interference commonly observed in real-world noise distributions. In addition, realistic artifacts are extracted and integrated into clean signals to model high-intensity, abrupt noise events. An encoder-decoder network designed with fixed temporal resolution is subsequently trained to recover the clean signals, guided by a loss function that captures both temporal and spectral characteristics. We evaluated SelfDenoiser on 11,392 hours of data collected in an Intensive Care Unit (ICU) using seismic sensor-based systems. The model was trained on 610 hours of clean signals selected from a 5176-hour unlabeled pool and tested on a 6216-hour labeled dataset. Results showed substantial improvements in two downstream tasks: heart rate (HR) and inter-beat interval (IBI) estimation, with notably increased data utilization and better accuracy compared to conventional denoising methods. This highlights SelfDenoiser's capability to transform low-quality, noisy signals into high-fidelity, reliable cardiac data.

12 January 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
ZPZaid Farooq Pitafi
Zaid Farooq Pitafi
HYHe Yang
He Yang
JCJiayu Chen
Jiayu Chen
YSYingjian Song
Yingjian Song
JYJin Ye
Jin Ye
WenZhan SongWenZhan Song
WenZhan Song
Contactless monitoring of vital signs such as Heart Rate (HR) and Respiratory Rate (RR) has gained significant attention, with vibration-based sensors like geophones showing promise for accurate, non-invasive monitoring. However, most existing systems are developed with healthy subjects and may not generalize well to extreme physiological ranges, such as those observed in infants or patients with arrhythmia. Moreover, the underlying mechanisms of cardiorespiratory vibration dynamics remain insufficiently understood, limiting clinical adoption of these systems. To address these challenges, we present a programmable cardiorespiratory testbed capable of generating realistic HR and RR signals across a wide range (HR: 40–240 bpm, RR: 8–40 bpm). Our system uses a voice coil motor that acts as the vibration source, driven by a Raspberry Pi based control circuit. Unlike similar systems that use separate modules for heart and lung signals, our setup generates both signals using a single motor. The synthetic signals exhibit a strong correlation of 0.85 compared with data from 75 human subjects. We use this system to design signal processing based algorithms for vital signs monitoring and demonstrate their robustness for extreme physiological ranges. The proposed system enhances the understanding of cardiorespiratory vibration dynamics while significantly reducing the time and effort required to collect real-world data.