Yida Zhang

Yida Zhang

Auto-generated profile, based on publicly available information

Yida Zhang

University of Georgia, Athens, USA

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 June 2025 in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
Verified
Journal Article
Open access
YSYingjian Song
Yingjian Song
HXHaotian Xiang
Haotian Xiang
ZZZixuan Zeng
Zixuan Zeng
JCJiayu Chen
Jiayu Chen
YZYida Zhang
Yida Zhang
WenZhan SongWenZhan Song
WenZhan Song
In-bed postures offer valuable information about an individual's sleep quality and overall health conditions, particularly for patients with sleep apnea. However, current in-bed posture classification systems lack privacy-friendly and easy-to-install options. Furthermore, existing solutions do not consider variations between patients and are typically trained only once, neglecting the utilization of time consistency and unlabeled data from new patients. To address these limitations, this paper builds on a seismic sensor to introduce a novel sleep posture framework, which comprises two main components, namely, the Multi-Granularity Supervised Contrastive Learning (MGSCL) module and the ensemble Online Adaptation (oa) module. Unlike most existing contrastive learning frameworks that operate at the sample level, MGSCL leverages multi-granular information, operating not only at the sample level but also at the group level. The oa module enables the model to adapt to new patient data while ensuring time consistency in sleep posture predictions. Additionally, it quantifies model uncertainty to generate weighted predictions, further enhancing performance. Evaluated on a dataset of 100 patients collected at a clinical research center, MGSCLoa achieved an average accuracy of 91.67% and an average F1 score of 91.53% with only 40 seconds of labeled data per posture. In a Phase 2 evaluation with 11 participants over 13 nights in home settings, the framework reached an average accuracy of 85.37% and a weighted F1 score of 83.59% using just 3 minutes of labeled data per common posture for each participant. These results underscore the potential of seismic sensor-based in-bed posture classification for assessing sleep quality and related health conditions.

4 November 2024
Verified
Conference Paper
Open access
YSYingjian Song
Yingjian Song
ZPZaid Farooq Pitafi
Zaid Farooq Pitafi
ZZZixuan Zeng
Zixuan Zeng
JCJiayu Chen
Jiayu Chen
YZYida Zhang
Yida Zhang
WenZhan SongWenZhan Song
WenZhan Song
Health monitoring is essential for both humans and animals in daily life. While numerous health monitoring systems have been developed, the majority are designed exclusively for either humans or animals, and most require direct physical contact. We have developed BedDot, a contactless health monitoring system for both humans and animals using a seismic sensor. BedDot can be deployed in various environments, such as bed and seat settings for humans, as well as in cages for animals, to monitor occupancy, heart rate (HR), respiratory rate (RR), and blood pressure (BP). Our system demonstrates high accuracy in the clinical experiments of 150 patients and 16 dogs and cats.

2 December 2025 in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
Verified
Journal Article
Open access
JCJiayu Chen
Jiayu Chen
YSYingjian Song
Yingjian Song
YZYida Zhang
Yida Zhang
ZZZixuan Zeng
Zixuan Zeng
XZXiang Zhang
Xiang Zhang
WenZhan SongWenZhan Song
WenZhan Song
Cardiovascular diseases (CVDs) remain a major global health challenge, highlighting the urgent need for advanced cardiac monitoring solutions. Continuous, contactless cardiac monitoring using seismic sensors enables comfortable, privacy-preserving assessments by capturing subtle heart vibrations. However, these systems are highly susceptible to diverse noise sources. Existing denoising methods struggle to handle the complex noise in cardiac seismic signals and poorly leverage the abundant unlabeled data. To address these challenges, we propose SelfDenoiser, a self-supervised framework for denoising and reconstructing cardiac seismic signals using unlabeled data. During training, SelfDenoiser first selects clean segments from the unlabeled pool, then injects adaptive noise into each segment to simulate shared, hard-to-remove interference commonly observed in real-world noise distributions. In addition, realistic artifacts are extracted and integrated into clean signals to model high-intensity, abrupt noise events. An encoder-decoder network designed with fixed temporal resolution is subsequently trained to recover the clean signals, guided by a loss function that captures both temporal and spectral characteristics. We evaluated SelfDenoiser on 11,392 hours of data collected in an Intensive Care Unit (ICU) using seismic sensor-based systems. The model was trained on 610 hours of clean signals selected from a 5176-hour unlabeled pool and tested on a 6216-hour labeled dataset. Results showed substantial improvements in two downstream tasks: heart rate (HR) and inter-beat interval (IBI) estimation, with notably increased data utilization and better accuracy compared to conventional denoising methods. This highlights SelfDenoiser's capability to transform low-quality, noisy signals into high-fidelity, reliable cardiac data.

15 June 2026 in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
Verified
Journal Article
Open access
JLJiahui Li
Jiahui Li
YZYida Zhang
Yida Zhang
ZZZixuan Zeng
Zixuan Zeng
JCJiayu Chen
Jiayu Chen
YSYingjian Song
Yingjian Song
FDFei Dou
Fei Dou
Accurate peak detection across diverse cardiac physiological signals, including the Electrocardiogram (ECG), Photoplethysmogram (PPG), Ballistocardiogram (BCG), and Bodyseismography (BSG), is fundamental for cardiovascular monitoring but is often hindered by artifacts and signal variability. Conventional algorithms are typically engineered with expert knowledge for a single signal modality, limiting their generalizability. Conversely, deep learning-based methods often lack interpretability, limiting transparency for expert verification and hindering expert-computer interaction. To address these limitations, we introduce Peak-Detector, a novel framework that leverages instruction-tuned Large Language Models (LLMs) for robust, cross-modal, and explainable peak detection. A core innovation of our framework is a “peak-representation” technique that transforms time-series data into a condensed format, preserving critical event information while significantly reducing signal length. This representation provides a crucial inductive bias, guiding the LLM to reason over physiologically meaningful events rather than raw, noisy data. The model is optimized through a two-stage process: supervised fine-tuning (SFT) followed by reinforcement learning (RL) with a multi-objective reward function. The model's self-explanation capabilities are cultivated by fine-tuning on a custom-built Peak-Explanation dataset. Across four modalities—ECG, PPG, BCG, and BSG—spanning seven datasets (six public benchmarks plus one real-world cohort), Peak-Detector demonstrates strong cross-modal performance, achieving best or tied-best detection under clinically relevant temporal tolerance. Beyond accuracy, the generated rationales surface failure modes and support verification and error analysis. Together, these results indicate a transparent and generalizable framework for trustworthy peak analysis and cardiovascular metric extraction.

26 October 2026
Verified
Conference Paper
Open access
YWYuyan Wu
Yuyan Wu
YZYuanyuan Zhang
Yuanyuan Zhang
YZYida Zhang
Yida Zhang
JLJiahui Li
Jiahui Li
FDFei Dou
Fei Dou
HNHae Young Noh
Hae Young Noh
Continuous arterial blood pressure (ABP) waveform monitoring provides beat-to-beat hemodynamic information for clinical decision-making. However, invasive arterial catheterization limits unobtrusive long-term use. We develop a contact-free method to reconstruct continuous ABP waveforms from triaxial bodyseismography (BSG) signals, which capture bed vibrations induced by cardiac mechanical activity. The key challenge is recovering physiologically meaningful beat-level ABP morphology from indirect, noisy signals transmitted through the body-to-bed pathway. To address this challenge, we develop a dual-branch framework that fuses temporal BSG with wavelet-based time-frequency representations, combining local beat-level morphology with global spectral context. In leave-one-subject-out evaluation on 33 ICU patients, our method achieved a mean absolute error of 12.8 mmHg and a peak normalized cross-correlation of 0.896.

8 June 1993 in ChemInform
Verified
Journal Article
Closed access
PDF file
GMG. Majetich
G. Majetich
YZY. Zhang
Y. Zhang
TFT. L. Feltman
T. L. Feltman
VBV. Belfoure
V. Belfoure