Zakaria M.S Elbarbary

Prof. Dr. Zakaria M.S Elbarbary

King Khalid University, Abhā, ‘Asīr, Saudi Arabia
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 September 2023 in IEEE Access
Verified
Journal Article
Open access
Nagwa .F IbrahimNagwa .F Ibrahim
Nagwa .F Ibrahim
Mohamed Metwally MahmoudMohamed Metwally Mahmoud
Mohamed Metwally Mahmoud
ATAli M. H. Al Thaiban
Ali M. H. Al Thaiban
ABAbdulwasa Bakr Barnawi
Abdulwasa Bakr Barnawi
Zakaria M.S ElbarbaryZakaria M.S Elbarbary
Zakaria M.S Elbarbary
HAHany Abdelfattah
Hany Abdelfattah
The expanding use of photovoltaics (PV) as a green energy resource has been rising in these years, mostly due to the possibility of being incorporated with traditional power systems, to meet the world’s energy needs and reduce carbon emissions. However, providing green electricity from this renewable generator is frequently vulnerable to power quality (PQ) disruptions resulting from the PV’s intermittent nature and other factors associated with the electric grid, power converters, and linked loads. These disruptions need to be reduced to keep the investigated system’s PQ from deteriorating. The investigated system includes PV, DC-DC, and DC-AC converters, filter, power grid, and control schemes. If the DC-DC converter is not managed, a deviation from the maximum power point (MPP) extrapolated from the PV system will take place. In order to maximize the energy harvested from the PV system by managing the DC-DC converter, this research developed two MPP tracking (MPPT) algorithms: artificial neural networks (ANN) and cuckoo search (CS). Additionally, a design and implementation for a shunt active power filter (LCL) using genetic algorithm and GRG is provided to lower the injected total harmonic distortion (THD) and thereby enhance the PQ. To achieve the smallest size of the LCL components, the generalized reduced gradient (GRG) was the best compared to genetic algorithms GA. The results of the simulation showed that ANN performed better at tracking maximum power than CS. With the designed LCL, the THD is reduced by 99.78% compared to without a filter. To verify the simulation’s findings, a practical configuration is implemented.

18 August 2023 in IEEE Access
Verified
Journal Article
Open access
HCHamid Chojaa
Hamid Chojaa
ADAziz Derouich
Aziz Derouich
OZOthmane Zamzoum
Othmane Zamzoum
AWAziz Watil
Aziz Watil
MTMohammed Taoussi
Mohammed Taoussi
Mahmoud A.MossaMahmoud A.Mossa
Mahmoud A.Mossa
This research work addresses the challenge of controlling a wind energy conversion system (WECS) connected to the grid, which incorporates a battery energy storage system and operates under varying real wind speed profiles. The system comprises a Doubly-Fed Induction Generator (DFIG) connected to the grid through an AC/DC/AC converter, along with a Li-ion battery pack storage unit linked to the Back-to-Back converter DC via a DC/DC converter. The study highlights that internal parametric variations and the non-linear behavior of the wind turbine negatively affect the energy quality produced, as well as the battery charging performance and its overall lifespan. To overcome these issues, the research proposes a robust control strategy based on Integral action Sliding Mode Control (ISMC) to independently manage the powers of the WECS, particularly the DFIG, to enhance dynamic performance. Furthermore, effective battery charging and discharging controllers are crucial for efficiently distributing the generated power to both the grid and the storage unit, ensuring proper energy extraction and battery charging/discharging. Depending on the battery’s State of Charge (SOC), the available extracted energy, and the power injected into the grid, two current regulation modes are employed: buck charging mode and boost discharging mode. A storage system energy management algorithm is then utilized to determine the appropriate charging mode, ensuring battery safety. To validate the system’s performance, a 1.5 MW wind power conversion system is tested using Matlab/Simulink simulations. The results demonstrate the robustness and efficiency of the proposed control approach in enhancing the overall system’s performance.

6 May 2021 in Frontiers in Engineering and Built Environment
Verified
Journal Article
Open access
PDF file
Zakaria M.S ElbarbaryZakaria M.S Elbarbary
Zakaria M.S Elbarbary
MAMohamed Abdullrahman Alranini
Mohamed Abdullrahman Alranini
Purpose Silicon photovoltaics technology has drawbacks of high cost and power conversion efficiency. In order to extract the maximum output power of the module, maximum power point (MPP) is used by implying the nonlinear behavior of I-V characteristics. Different techniques are used regarding maximum power point tracking (MPPT). The paper aims to review the techniques of MPPT used in PV systems and review the comparison between Perturb and Observe (P&O) method and incremental conductance (IC) method that are used to track the maximum power and gives a comparative review of all those techniques. Design/methodology/approach A study of MPPT techniques for photovoltaic (PV) systems is presented. Matlab Simulink is used to find the MPP using P&O simulation along with IC simulation at a steady temperature and irradiance. Findings MATLAB simulations are used to implement the P&O method and IC method, which includes a PV cell connected to an MPPT-controlled boost converter. The simulation results demonstrate the accuracy of the PV model as well as the functional value of the algorithms, which has improved tracking efficiency and dynamic characteristics. P&O solution gave 94% performance when configured. P&O controller has a better time response process. As compared to the P&O method of tracking, the incremental conductance response rate was significantly slower. Originality/value In PV systems, MPPT techniques are used to optimize the PV array output power by continuously tracking the MPP under a variety of operating conditions, including cell temperature and irradiation level.

27 June 2025 in IEEE Access
Verified
Journal Article
Open access
EAEmrah ASLAN
Emrah ASLAN
YÖyıldırım özüpak
yıldırım özüpak
FAFeyyaz ALPSALAZ
Feyyaz ALPSALAZ
Zakaria M.S ElbarbaryZakaria M.S Elbarbary
Zakaria M.S Elbarbary
Power transformers are critical components in ensuring the continuous and stable operation of power systems. Failures in these units can lead to significant power outages and costly downtime. Existing maintenance strategies often fail to accurately predict such failures, highlighting the need for novel predictive approaches. This study aims to improve the reliability of power systems by predicting transformer failures through the integration of IoT technologies and advanced machine learning techniques. The proposed hybrid model combines the LightGBM algorithm with GridSearch optimization to achieve both high predictive accuracy and computational efficiency. In addition, the model enhances interpretability by incorporating SHapley Additive exPlanations (SHAP) and Local Interpretable Model-Agnostic Explanations (LIME) for transparent decision making. The study presents a detailed comparison of different classification algorithms and evaluates their performance using metrics such as accuracy, recall, and F1 score. The results show that the hybrid model outperforms other methods, achieving an accuracy of 99.91%. The SHAP and LIME analyses provide engineers and researchers with valuable insights by highlighting the most influential features in failure prediction. In addition, the model’s ability to efficiently handle large data sets enhances its practicality in real-world power systems. By proposing an innovative approach to failure prediction, this research contributes to both the theoretical foundation and practical advancement of sustainable and reliable energy infrastructures.

9 December 2024 in Heliyon
Verified
Journal Article
Open access
WWWaqar Waheed
Waqar Waheed
QXQingshan Xu
Qingshan Xu
MAMuhammad Aurangzeb
Muhammad Aurangzeb
Sheeraz IqbalSheeraz Iqbal
Sheeraz Iqbal
SDSaadat Hanif Dar
Saadat Hanif Dar
Zakaria M.S ElbarbaryZakaria M.S Elbarbary
Zakaria M.S Elbarbary
The integration of renewable energy sources has resulted in an increasing intricacy in the functioning and organization of power systems. Accurate load forecasting, particularly taking into account dynamic factors like as climatic and socioeconomic impacts, is essential for effective management. Conventional statistical analysis and machine learning methods struggle with accurately capturing the intricate temporal relationships present in load data. Recurrent neural networks (RNNs), specifically long short-term memory (LSTM) networks, demonstrate potential in representing and interpreting sequences of data. This study presents an approach that employs an LSTM-RNN model for load forecast prediction. This study highlights the importance of this technology in combining effective demand response with distributed renewable energy sources, which are crucial for the stability of smart grids and accurate power demand estimation. The LSTM-RNN model has outstanding accuracy, with a Mean Absolute Percentage Error (MAPE) of 1.5% and a Root Mean Squared Error (RMSE) of 26.5 for hourly forecasts. Additionally, it achieves a MAPE of 1.77% and an RMSE of 30 for yearly load estimations. The hourly LSTM-RNN load forecast model outperforms the yearly LSTM-RNN load forecast model, as evidenced by lower error rates. Importantly, this model demonstrates robustness even when the inputs are inadequate or noisy. To summarize, this research suggests that LSTM-RNN is a practical and efficient approach for precisely forecasting load in power systems. This underscores its capacity to enhance operational efficiency and resilience in power systems.

9 January 2023 in IEEE Access
Verified
Journal Article
Open access
NANoura A. Nour Aldin
Noura A. Nour Aldin
WAWalid S. E. Abdellatif
Walid S. E. Abdellatif
Zakaria M.S ElbarbaryZakaria M.S Elbarbary
Zakaria M.S Elbarbary
Ahmed I. OmarAhmed I. Omar
Ahmed I. Omar
Mohamed Metwally MahmoudMohamed Metwally Mahmoud
Mohamed Metwally Mahmoud
Modern wind power systems have recently tended to focus on achieving fast-tracking wind speeds (WSs), high maximum power point tracking (MPPT) efficacy without mechanical sensors, and high performance under uncertain WS together with an effective control system. Therefore, a sensorless MPPT method is introduced, which calculates the actual WS to save system installation costs and boost performance levels. The implemented MPPT method is based on the approximating of the 3-order polynomial to the aerodynamics torque power coefficient. In this study, three-speed control strategies (SCSs) for a grid-connected permanent magnet synchronous wind generator (PMSWG) are examined and assessed. Harris Hawks’ algorithm (HHA)-based PI controller (HHA-PIC) is used in place of (the conventional proportional-integral controller (CPIC), and adaptive fuzzy logic controller (AFLC)) as a speed controller to overcome their drawbacks. To track the generator speed to the desired speed, the HHA-PIC is used. All the CPIC, AFLC, and HHA-PIC have been carefully thought out and constructed to satisfy the speed control loop’s responsive performance. Additionally, a comparison of SCSs amongst the categories under investigation is done. The effect of HHA on the functionality of SCS is verified using MATLAB/SIMULINK. To ensure the efficacy and supremacy of the HHA-PIC over the CPIC and AFLC, a wide variety of WSs (step change, ramp, and real fluctuations) are applied. Finally, it can be said that HHA is a crucial remedy for the problems with CPIC and is superior to AFLC.