Zhuo Liu

Dr. Zhuo Liu

CHINT Low Voltage Intelligent Electrical R&D Center, Zhejiang Chint Electrics Co., Ltd., Shanghai, China
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 August 2017 in Energies
Verified
Journal Article
Open access
PDF file
ZLZhuo Liu
Zhuo Liu
TWTianzhen Wang
Tianzhen Wang
TTTianhao Tang
Tianhao Tang
Yide WANGYide WANG
Yide WANG
Cascaded H-bridge Multilevel Inverter (CHMI) is widely used in industrial applications thanks to its many advantages. However, the reliability of a CHMI is decreased with the increase of its levels. Fault diagnosis techniques play a key role in ensuring the reliability of a CHMI. The performance of a fault diagnosis method depends on the characteristics of the extracted features. In practice, some extracted features may be very similar to ensure a good diagnosis performance at some H-bridges of CHMI. The situation becomes even worse in the presence of noise. To fix these problems, in this paper, signal denoising and data preprocessing techniques are firstly developed. Then, a Principal Components Rearrangement method (PCR) is proposed to represent the different features sufficiently distinct from each other. Finally, a PCR-based fault diagnosis strategy is designed. The performance of the proposed strategy is compared with other fault diagnosis strategies, based on a 7-level CHMI hardware platform.

3 June 2019 in Energies
Verified
Journal Article
Open access
PDF file
MZMilu Zhang
Milu Zhang
TWTianzhen Wang
Tianzhen Wang
TTTianhao Tang
Tianhao Tang
ZLZhuo Liu
Zhuo Liu
Christophe ClaramuntChristophe Claramunt
Christophe Claramunt
Affected by high density, non-uniform, and unstructured seawater environment, fault detection of Marine Current Turbine (MCT) faces various fault features and strong interferences. To solve these problems, a harmonic analysis strategy based on zero-crossing estimation and Empirical Mode Decomposition (EMD) filter banks is proposed. First, the detection problems of rotor imbalance fault under strong interference conditions are described through an analysis of the fault mechanism and operation environment of MCT. Therefore, against various fault features, a zero-crossing estimation is proposed to calculate instantaneous frequency. Last, and in order to solve the problem that the frequency and amplitude of the operating parameters are partially or completely covered by interference, a band-pass filter based on EMD is used, together with a characteristic frequency selected by a Pearson correlation coefficient. This strategy can accurately detect the multiplicative faults under strong interference conditions, and can be applied to the MCT fault detection system. Theoretical and experimental results verify the effectiveness of the proposed strategy.

16 December 2020 in Energies
Verified
Journal Article
Open access
PDF file
ZLZhuo Liu
Zhuo Liu
Azeddine HouariAzeddine Houari
Azeddine Houari
Mohamed MachmoumMohamed Machmoum
Mohamed Machmoum
Mohamed Fouad BENKHORISMohamed Fouad BENKHORIS
Mohamed Fouad BENKHORIS
TTTianhao Tang
Tianhao Tang
In recent years, multi-phase permanent magnet synchronous generators (PMSGs) have become attractive in the field of tidal current energy conversion systems (TCECS) due to their high-power density, reliability, and availability. However, external disturbances and malfunctions in power conversion chains will bring challenges to achieving stable and continuous tidal current energy harnessing. Using generalized proportional integral observers, an active fault-tolerant control (AFTC) strategy is therefore proposed for a five-phase PMSG based TCECS that is subjected to an open switch fault (OSF) in the generator side converter. This proposed AFTC strategy is applied into q-axis current control loops, which contain fault detection and compensation. The fault compensator will be smoothly activated using a sigmoid function once the OSF is detected. Finally, a small-scale power experimental platform emulating the TCECS is established in order to verify the feasibility and efficiency of the proposed FTC strategy. Experiment results show that this AFTC strategy can detect faults rapidly and effectively attenuate torque ripples in the post-fault operation mode.

18 October 2020
Verified
Conference Paper
Closed access
ZLZhuo Liu
Zhuo Liu
Azeddine HouariAzeddine Houari
Azeddine Houari
MMMohamed Machmoum
Mohamed Machmoum
MBMohamed Fouad Benkhoris
Mohamed Fouad Benkhoris
TTTianhao Tang
Tianhao Tang
Comparing with classical three phase generators, multiphase ones attract more and more attention for industrial applications due to their capability of fault tolerance, high quality of output power and so on. In the event of a fault occurrence, before reconfiguring the control algorithms, it is necessary to detect the fault. A second order filter-based fault detection method is thus proposed in this paper and applied to a five-phase permanent magnet synchronous generator. The method is based on the analysis of the phase current in the natural basis when it varies suddenly. Thus, a second order filter is studied with a view to detecting faults and defining a fast indicator extracted from the derivative of the phase current. This approach is then applied to tidal energy conversion chain using a five-phase PMSG with non-sinusoidal EMF. Two faults are investigated successfully: open phase fault of the generator and open switch fault in its serial converter legs.


25 October 2021 in IEICE Electronics Express
Verified
Journal Article
Closed access
PDF file
ZLZhuo Liu
Zhuo Liu
Azeddine HouariAzeddine Houari
Azeddine Houari
MMMohamed Machmoum
Mohamed Machmoum
MBMohamed-Fouad Benkhoris
Mohamed-Fouad Benkhoris
TTTianhao Tang
Tianhao Tang
Using multiphase permanent magnet synchronous generators (PMSG) is able to strengthen whole reliabilities of the tidal stream energy systems. Even so, advanced fault-tolerant control designs are also needed for a further enhancement of multiphase PMSG integrated tidal stream turbine under harsh sea water environments. Thus, extended state observers are used to develop a fault-tolerant control strategy towards a trapezoidal five-phase PMSG incorporated tidal stream application. This FTC strategy considers open circuit of a phase and a switch in the five-phase PMSG and its connected converter. To attenuate influences due to these faults, a dual-loop compensation mechanism is performed via extended state observers. System adaptation to swell effects of the tidal stream and feasibility of the proposed FTC strategy are verified through a 1.5 MW simulation setup.