The use of diesel generators to supply electricity to small remote islands is both costly and environmentally troublesome. On the other hand, small island networks pose peculiar stability and reliability problems when renewable energy sources are added. The paper regards the installation of an hybrid power plant (phortovoltaic, PV, plus lithium battery and synchronous condenser) in Giglio island, to replace existing diesel units. The paper discusses the general overview of the project and presents steady-state and dynamic simulations of the proposed energy system. Results evidence the advantages of the proposed Giglio hybrid power plant over existing diesel generators in terms of reduction of both pollution and energy costs, also allowing to fulfill the N-1 network security criterion. At the same time, results underline the need to install a properly sized flywheel in order to assure the stability of supply.
This paper offers a wide overview on the large-scale electrochemical energy projects installed in the high voltage Italian grid. Detailed descriptions of energy (charge/discharge times of about 8 h) and power intensive (charge/discharge times ranging from 0.5 h to 4 h) installations are presented with some insights into the authorization procedures, safety features, and ancillary services. These different charge/discharge times reflect the different operation uses inside the electric grid. Energy intensive storage aims at decoupling generation and utilization since, in the southern part of Italy, there has been a great growth of wind farms: these areas are characterized by a surplus of generation with respect to load absorption and to the net transport capacity of the 150 kV high voltage backbones. Power intensive storage aims at providing ancillary services inside the electric grid as primary and secondary frequency regulation, synthetic rotational inertia, and further functionalities. The return on experience of Italian installations will be able to play a key role also for other countries and other transmission system operators.
This paper presents an experimental application of LiFePO4 battery energy storage systems (BESSs) to primary frequency control, currently being performed by Terna, the Italian transmission system operator (TSO). BESS performance in the primary frequency control role was evaluated by means of a simplified electrical-thermal circuit model, taking into account also the BESS auxiliary consumptions, coupled with a cycle-life model, in order to assess the expected life of the BESS. Numerical simulations have been carried out considering the system response to real frequency measurements taken in Italy, spanning a whole year; a parametric study taking into account different values of governor droop and of BESS charge/discharge rates (C-rates) was also performed. Simulations, fully validated by experimental results obtained thus far, evidenced a severe trade-off between expected lifetime and overall efficiency, which significantly restricts the choice of operating parameters for frequency control.
This paper deals with the power conversion system architectures to interface a stationary electrochemical storage installation with the network. Theoretical justifications about the conversion system layouts and control, used for actual Italian installations, are given. This paper aims at giving the power energy society an overview of actual possibilities of static conversion of d.c. battery sources.
The paper describes the results of different types of ageing tests performed by Terna (the Italian Transmission System Operator) applied to several electrochemical technologies, namely lithium-based and sodium-nickel chloride-based technologies. In particular, the tested lithium-based technologies exploit a graphite-based anode and the following cathode electrochemistries: lithium iron phosphate, lithium nickel cobalt aluminium, lithium nickel cobalt manganese, and lithium titanate. These tests have been performed in the storage labs located in Sardinia (Codrongianos) and Sicily (Ciminna). The aim of the storage labs is intended to give the electrical grid ancillary services, for example, primary frequency regulation, secondary frequency regulation, voltage regulation, synthetic rotational inertia provision, and many more. For the primary frequency regulation service, the ageing of the batteries is difficult to foresee as the ageing tests are not standardized. The authors proposed some novel cycle types, which showed that, in several cases, the frequency regulation cycle ages the batteries much more than the standard cycle. The standard cycle definition has been adopted in the paper to identify a battery cycle test that was carried out to uniformly compare and rank the different technologies. Moreover, sodium-nickel chloride batteries are unaffected by the types of cycle and have a negligible ageing. In addition, lithium manganese oxide and lithium titanate batteries show very good behaviour with a slight degradation of the dischargeable energy, irrespectively of the type of cycle. Inversely, lithium nickel cobalt aluminium technology shows a considerable ageing and a strong dependence on the cycle types. Even if the theoretical explanations of such aging behaviours need time to be understood and expounded, the authors are convinced that the scientific community should become aware of these experimental results.
10 March 2021 in IEEE Transactions on Power Delivery
The paper deals with a final experimental validation of three-dimensional Multiconductor Cell Analysis (MCA) developed by the Electric Energy Transmission Laboratory of the University of Padova. This final confirmation comes from the measurement campaign carried out on one of the longest (100 km) HVAC submarine three-core cables: the Sicily-Malta interconnector. The considered frequency measurements range from 0 to 40 th harmonic order with both positive and zero sequence supplies. In this overall harmonic interval and with both supplies, the comparison between measurements and MCA results highlights a very good agreement (maximum differences of 10%). These differences are negligible if measurement uncertainties are considered.