Abhinav Prasad

Dr. Abhinav Prasad


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 July 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
APAbhinav Prasad
Abhinav Prasad
RMRichard Middlemiss
Richard Middlemiss
ANAndreas Noack
Andreas Noack
KAKristian Anastasiou
Kristian Anastasiou
SBSteven G. Bramsiepe
Steven G. Bramsiepe
GHGiles D. Hammond
Giles D. Hammond
The measurement of tiny variations in local gravity enables the observation of subterranean features. Gravimeters have historically been extremely expensive instruments, but usable gravity measurements have recently been conducted using MEMS (microelectromechanical systems) sensors. Such sensors are cheap to produce, since they rely on the same fabrication techniques used to produce mobile phone accelerometers. A significant challenge in the development of MEMS gravimeters is maintaining stability over long time periods, which is essential for long term monitoring applications. A standard way to demonstrate gravimeter stability and sensitivity is to measure the periodic elastic distortion of the Earth due to tidal forces—the Earth tides. Here, a 19 day measurement of the Earth tides, with a correlation coefficient to the theoretical signal of 0.975, has been presented. This result demonstrates that this MEMS gravimeter is capable of conducting long-term time-lapse gravimetry, a functionality essential for applications such as volcanology.

18 August 2014 in The Analyst
Verified
Journal Article
Open access
PDF file
APAbhinav Prasad
Abhinav Prasad
ALA. T.-H. Lin
A. T.-H. Lin
VRV. R. Rao
V. R. Rao
ASASHWIN A. SESHIA
ASHWIN A. SESHIA
A bulk acoustic mode micro-electro-mechanical dual resonator platform is utilised to study the evaporation of sub-microliter water droplets from the surface of the resonator. An analytical formulation for the observed frequency shift and the measure dependence of resonant frequency on the modes of evaporation which is consistent with the optically derived data. The resonators access only a thin layer of the liquid through shear contact and, hence, the response is not affected by the bulk mass of the droplet to first order. A relationship between the droplet contact area and the elapsed time was established for the evaporation process and is used to derive a value of the diffusion coefficient of water in air that is found to be in reasonable agreement with literature values. This work introduces a new tool for the electro-mechanical monitoring of droplet evaporation with relevance to applications such as biosensing in liquid samples of sub-microliter volumes.

1 February 2016 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
APAbhinav Prasad
Abhinav Prasad
JCJerome Charmet
Jerome Charmet
ASASHWIN A. SESHIA
ASHWIN A. SESHIA

1 January 2016 in Ultrasonics
Verified
Journal Article
Closed access
MAMegha Agrawal
Megha Agrawal
APAbhinav Prasad
Abhinav Prasad
JBJayesh Bellare
Jayesh Bellare
ASASHWIN A. SESHIA
ASHWIN A. SESHIA

19 March 2018 in Applied Nanoscience
Verified
Journal Article
Closed access
PDF file
DADilip Kumar Agarwal
Dilip Kumar Agarwal
APAbhinav Prasad
Abhinav Prasad
MVMadhuri Vinchurkar
Madhuri Vinchurkar
SGSahir Gandhi
Sahir Gandhi
DPDeepika Prabhakar
Deepika Prabhakar
VRV. Ramgopal Rao
V. Ramgopal Rao

1 October 2018
Verified
Conference Paper
Closed access
APAbhinav Prasad
Abhinav Prasad
SBS. G. Bramsiepc
S. G. Bramsiepc
RMR. P. Middlemiss
R. P. Middlemiss
JHJ. Hough
J. Hough
SRS. Rowan
S. Rowan
DPD. J. Paul
D. J. Paul
Gravimeters are used for measuring the local gravitational acceleration. The use of current commercially available gravimeters, however, has been limited by their high cost and large size. In this study, a microelectromechanical system (MEMS) based relative gravimeter with an acceleration sensitivity of 8 μGall / √ (Hz) is demonstrated. The MEMS gravimeter, along with the custom interface electronics, is embedded on a battery powered portable platform. The portable platform enables continuous recording of the sensor response, while simultaneously measuring critical temperature and tilt parameters. To demonstrate the long-term stability of the system, the reported MEMS gravimeter platform was used to detect the Earth tides. In this paper, the first results from these measurements have been discussed.