Maciej Janeczek

Prof. Dr. Maciej Janeczek

Wroclaw University of Environmental and Life Sciences, Wroclaw, Poland
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 December 2020 in Materials
Verified
Journal Article
Open access
PDF file
Viktoria HoppeViktoria Hoppe
Viktoria Hoppe
Patrycja Szymczyk-ZiółkowskaPatrycja Szymczyk-Ziółkowska
Patrycja Szymczyk-Ziółkowska
MRMałgorzata Rusińska
Małgorzata Rusińska
BDBogdan Dybała
Bogdan Dybała
DPDominik Poradowski
Dominik Poradowski
Maciej JaneczekMaciej Janeczek
Maciej Janeczek
The purpose of this work is to obtain comprehensive reference data of the Ti-13Nb-13Zr alloy base material: its microstructure, mechanical, and physicochemical properties. In order to obtain extensive information on the tested materials, a number of examination methods were used, including SEM, XRD, and XPS to determine the phases occurring in the material, while mechanical properties were verified with static tensile, compression, and bending tests. Moreover, the alloy’s corrosion resistance in Ringer’s solution and the cytotoxicity were investigated using the MTT test. Studies have shown that this alloy has the structure α’, α, and β phases, indicating that parts of the β phase transformed to α’, which was confirmed by mechanical properties and the shape of fractures. Due to the good mechanical properties (E = 84.1 GPa), high corrosion resistance, as well as the lack of cytotoxicity on MC3T3 and NHDF cells, this alloy meets the requirements for medical implant materials. Ti-13Nb-13Zr alloy can be successfully used in implants, including bone tissue engineering products and dental applications.

1 July 2014 in The Angle Orthodontist
Verified
Journal Article
Closed access
MMMarcin Mikulewicz
Marcin Mikulewicz
PWPaulina Wołowiec
Paulina Wołowiec
Maciej JaneczekMaciej Janeczek
Maciej Janeczek
TGThomas Gedrange
Thomas Gedrange
KCKatarzyna Chojnacka
Katarzyna Chojnacka
Objective: To investigate the release of metal ions from an orthodontic appliance in tests on animals (pigs). Materials and Methods: An animal test was conducted on 24 pigs divided equally into an experimental and a control group. In total, 12 sets of experimental orthodontic plates were surgically inserted into pig snouts in the experimental group for 6 months. Noninvasive matrices (hair [0, 3, and 6 months]) and invasive matrices (kidneys, liver, lungs, aorta, and oral mucosa) were collected for multi-elemental analysis (inductively coupled plasma optical emission spectrometry) from the experimental and control groups. Results: The greatest differences in the content of toxic metals were found in the aorta (Ni level was 4.8 times higher in experimental than in the control group), in the cheek (Ni 3.5 times higher), and in the hair sampled after 3 months (Cr 3.4 times higher). Conclusions: The obtained data indicate that the products of corrosion have passed into selected tissues of pigs; however, the doses of toxic metal ions released from the appliance did not reach toxic levels.

Verified
Journal Article
Open access
PDF file
Kamil NelkeKamil Nelke
Kamil Nelke
AMAlicja Morawska
Alicja Morawska
BBBartłomiej Błaszczyk
Bartłomiej Błaszczyk
Maciej JaneczekMaciej Janeczek
Maciej Janeczek
Edyta PasickaEdyta Pasicka
Edyta Pasicka
Maciej DobrzyńskiMaciej Dobrzyński
Maciej Dobrzyński
The buccal fat pad, also called the Bichat’s fat pad (BFP), is an encapsulated fat mass located in the cheek. This type of specialized fat mass can be used both as a pedicular or free graft in various surgeries and approaches. Due to its easy access from the oral cavity approach, it is commonly used for oroantral and palatal fistula closure. The knowledge of its anatomy and surrounding tissues plays a role in its mobilization and suturing onto the desired defect in the palatal or maxillary region. The BFP is mostly associated with the primary approach used for a fistula or bone surgery. Alternatively, the procedure can be performed with a single approach incision, which does not compromise the appearance or the function of the operating or adjacent areas. The most important inclusion criteria for BFP usage and surgical limitations are highlighted. The BFP is used for multiple purposes in reconstructive and oncology surgery and also has its use in esthetic and facial contouring procedures. The amount, volume, and shape of the BFP are mostly associated with the scope of their usage. The aim of the following narrative review is to present the surgical and anatomical implications of fat pads in maxillary and palatal surgeries.

23 April 2012 in International Journal of Osteoarchaeology
Verified
Journal Article
Closed access
PDF file
Maciej JaneczekMaciej Janeczek
Maciej Janeczek
ADAleksander Chrószcz, DVM
Aleksander Chrószcz, DVM
Vedat OnarVedat Onar
Vedat Onar
RHRadomir Z. Henklewski
Radomir Z. Henklewski
JPJerzy Piekalski
Jerzy Piekalski
ICI. Całkosiński
I. Całkosiński

1 May 2017 in Journal of Trace Elements in Medicine and Biology
Verified
Journal Article
Closed access
PKPiotr Kosior
Piotr Kosior
Maciej DobrzyńskiMaciej Dobrzyński
Maciej Dobrzyński
Mariusz KorczyńskiMariusz Korczyński
Mariusz Korczyński
KHKatarzyna Herman
Katarzyna Herman
ACAgnieszka Czajczyńska-Waszkiewicz
Agnieszka Czajczyńska-Waszkiewicz
Maciej JaneczekMaciej Janeczek
Maciej Janeczek

2 June 2020 in Polymers
Verified
Journal Article
Open access
PDF file
DKDorota Kida
Dorota Kida
OGOlimpia Gładysz
Olimpia Gładysz
MSMałgorzata Szulc
Małgorzata Szulc
JZJacek Zborowski
Jacek Zborowski
Adam JunkaAdam Junka
Adam Junka
BKBozena Karolewicz
Bozena Karolewicz
The aim of this study was to develop and assess a polyvinyl alcohol-cellulose derivatives-based film with incorporated povidone-iodine (PVP-I) predicted for applications in the treatment of periodontitis. Films were fabricated by solvent-casting, and their physical characteristics, such as their surface and structure morphology, mechanical properties, and disintegrating time, were evaluated. For in vitro iodine release studies and evaluation, the antimicrobial activity was tested using a modified disc diffusion method against five microbial strains. For further use, we selected the film with polyvinyl alcohol-hydroxypropyl methylcellulose (PVA/HPMC_B) based on acceptable physicochemical properties. To assess the subacute toxicity of the film composition, the tissue regeneration process was tested in rats and compared to a conventional dressing commonly used in wound healing (Spongostan). Seven days after implantation, dorsal skin sections and blood samples (n = 10, in total n = 30) were examined. The wound area, epithelium, and dermis were evaluated microscopically, while the blood collected from the rats underwent biochemical analysis. The blood biochemistry results were comparable in all three groups. No significant histological differences between the Spongostan and the placebo film developed after subcutaneous implantation were observed. In contrast, the inflammation stage was reduced and the “scar” in the dermis was smaller when PVP-I and PVA/HPMC_B films were used. A smaller local inflammatory response inflicted less tissue damage, leading to the activation of subsequent regeneration phases and restoration of the area to its original state. The results obtained confirmed that PVP-I incorporated into PVA-hydroxypropyl methylcellulose film is a promising drug carrier, working faster and more effectively than the other two dressing materials evaluated. These developments provide a promising alternative in tissue regeneration and the wound healing process.