In this work, we present a novel technique to locate partial discharge (PD) sources based on the concept of time reversal. The localization of the PD sources is of interest for numerous applications, including the monitoring of power transformers, Gas Insulated Substations, electric motors, super capacitors, or any other device or system that can suffer from PDs. To the best of the authors’ knowledge, this is the first time that the concept of time reversal is applied to localize PD sources. Partial discharges emit both electromagnetic and acoustic waves. The proposed method can be used to localize PD sources using either electromagnetic or acoustic waves. As a proof of concept, we present only the results for the electromagnetic case. The proposed method consists of three general steps: (1) recording of the waves from the PD source(s) via proper sensor(s), (2) the time-reversal and back-propagation of the recorded signal(s) into the medium using numerical simulations, and (3) the localization of focal spots. We demonstrate that, unlike the conventional techniques based on the time difference of arrival, the proposed time reversal method can accurately localize PD sources using only one sensor. As a result, the proposed method is much more cost effective compared to existing techniques. The performance of the proposed method is tested considering practical scenarios in which none of the former developed methods can provide reasonable results. Moreover, the proposed method has the unique advantage of being able to locate multiple simultaneous PD sources and doing so with a single sensor. The efficiency of the method against the variation in the polarization of the PDs, their length, and against environmental noise is also investigated. Finally, the validity of the proposed procedure is tested against experimental observations.
In this paper, we propose and implement a novel technique to locate Electromagnetic Interference (EMI) sources using the concept of time reversal cavity. We show in an intuitive manner that reflections from the surfaces of a cavity can emulate an infinite number of sensors in the Time Reversal (TR) method. In order to locate EMI sources, the equipment under test (EUT) is placed in a rectangular metallic cavity, of suitable dimensions according to the considered frequency band and the EUT size, equipped with a simple monopole or dipole antenna. We demonstrate that, by using only one sensor, we are able to locate EMI sources by taking advantage of the focusing properties of a time reversal cavity. The entropy criterion is applied to obtain the focusing time slice in which the maximum electric field determines the location of the EMI source. Both two- and three-dimensional numerical simulation schemes are deployed to demonstrate the ability of the proposed technique. The validity of numerical simulations is tested against frequency domain measurements. Compared to conventional EMI tests in anechoic chambers and scanning methods, the proposed technique represents a simpler and cost-effective test method requiring only one sensor (a monopole or dipole antenna).
1 February 2012 in Composites Science and Technology
The paper presents a comprehensive approach for full-wave modeling of grounding systems buried in a multilayer stratified ground. The dyadic spectral domain Green's function associated with the multilayer stratified ground is first derived. This Green's function is then evaluated by numerical solution of Sommerfeld's integrals along the deformed path in the complex plane. The proposed method is general as it can deal with arbitrarily shaped grounding electrodes buried in soils with any number of layers. The case of horizontal, vertical, and oblique electrodes buried in soils with different layers is analyzed. The accuracy of the proposed approach is first validated by comparing the results with those obtained by NEC-4 for a homogeneous soil, and with those obtained by finite difference time domain method for a multilayer soil.