Emile Martincic

Dr. Emile Martincic

Centre de Nanosciences et de Nanotechnologies, Universite Paris-Saclay, 91190 Saint-Aubin, France
orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 January 2010 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
MKM. El Kurdi
M. El Kurdi
HBH. Bertin
H. Bertin
EMEmile Martincic
Emile Martincic
MKM. de Kersauson
M. de Kersauson
GFG. Fishman
G. Fishman
PBP. Boucaud
P. Boucaud
We show that the recombination energy of the direct band gap photoluminescence (PL) of germanium can be controlled by an external mechanical stress. The stress is provided by an apparatus commonly used for bulge or blister test. An energy redshift up to 60 meV is demonstrated for the room temperature PL of a thin germanium membrane (125 nm wavelength shift from 1535 to 1660 nm). This PL shift is correlated with the in-plane tensile strain generated in the film. A biaxial tensile strain larger than 0.6% is achieved by this method. This mechanical strain allows to approach the direct band gap condition for germanium which is of tremendous importance to achieve lasing with this material.

23 August 2012 in IEEE Sensors Journal
Verified
Journal Article
Closed access
ISIman Shahosseini
Iman Shahosseini
ELElie Lefeuvre
Elie Lefeuvre
JMJohan Moulin
Johan Moulin
EMEmile Martincic
Emile Martincic
MWMarion Woytasik
Marion Woytasik
GLGuy Lemarquand
Guy Lemarquand
A novel structure of electrodynamics microelectromechanical systems (MEMS) microspeaker designed for mobile electronics is proposed in this paper. The originality of the device lies on the use of a rigid silicon membrane suspended by highly flexible silicon springs, contrary to most MEMS and non-MEMS microspeakers, which use polymer diaphragms. Important rigidity of the membrane and high linearity of the magnetic actuation conferred outstanding sound quality. The design of the silicon springs enabled large out-of-plane displacement of the membrane, which improved the bass rendering and the acoustic intensity over the whole bandwidth. The low density of silicon material helped to reduce the mobile mass and thus improved the microspeaker efficiency. A prototype with a membrane diameter of 15 mm and a thickness of 20 μm is microfabricated and characterized. The silicon springs enabled out-of-plane displacement of more than 300 μm. Acoustic intensity of 80-dB SPL is measured at 10 cm with 500-mW input power. This sound pressure level is obtained at frequencies from 330 Hz up to 70 kHz. Thanks to the membrane backside microstructure, most of the membrane proper modes are shifted out of the audible bandwidth. The measured electroacoustic efficiency is almost three times better than that of conventional microspeakers.

26 April 2019 in Sensors
Verified
Journal Article
Open access
PDF file
SBSylvie Bilent
Sylvie Bilent
TDThi-Hong-Nhung Dinh
Thi-Hong-Nhung Dinh
EMEmile Martincic
Emile Martincic
PJPierre-Yves Joubert
Pierre-Yves Joubert
This paper reports on the study of microporous polydimethylsiloxane (PDMS) foams as a highly deformable dielectric material used in the composition of flexible capacitive pressure sensors dedicated to wearable use. A fabrication process allowing the porosity of the foams to be adjusted was proposed and the fabricated foams were characterized. Then, elementary capacitive pressure sensors (15 × 15 mm2 square shaped electrodes) were elaborated with fabricated foams (5 mm or 10 mm thick) and were electromechanically characterized. Since the sensor responses under load are strongly non-linear, a behavioral non-linear model (first order exponential) was proposed, adjusted to the experimental data, and used to objectively estimate the sensor performances in terms of sensitivity and measurement range. The main conclusions of this study are that the porosity of the PDMS foams can be adjusted through the sugar:PDMS volume ratio and the size of sugar crystals used to fabricate the foams. Additionally, the porosity of the foams significantly modified the sensor performances. Indeed, compared to bulk PDMS sensors of the same size, the sensitivity of porous PDMS sensors could be multiplied by a factor up to 100 (the sensitivity is 0.14 %.kPa−1 for a bulk PDMS sensor and up to 13.7 %.kPa−1 for a porous PDMS sensor of the same dimensions), while the measurement range was reduced from a factor of 2 to 3 (from 594 kPa for a bulk PDMS sensor down to between 255 and 177 kPa for a PDMS foam sensor of the same dimensions, according to the porosity). This study opens the way to the design and fabrication of wearable flexible pressure sensors with adjustable performances through the control of the porosity of the fabricated PDMS foams.

1 November 2006 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
MWM. Woytasik
M. Woytasik
JGJ.-P. Grandchamp
J.-P. Grandchamp
EDE. Dufour-Gergam
E. Dufour-Gergam
JGJ.-P. Gilles
J.-P. Gilles
SMS. Megherbi
S. Megherbi
PCP. Crozat
P. Crozat

11 December 2007 in Microsystem Technologies
Verified
Journal Article
Closed access
PDF file
CSChristophe Serre
Christophe Serre
Alejandro Pérez-RodróhiezAlejandro Pérez-Rodróhiez
Alejandro Pérez-Rodróhiez
NFNuria Fondevilla
Nuria Fondevilla
EMEmile Martincic
Emile Martincic
SMSusanna Martínez
Susanna Martínez
JEJaume Esteve
Jaume Esteve

10 November 2006 in Microsystem Technologies
Verified
Journal Article
Closed access
PDF file
MWM. Woytasik
M. Woytasik
JGJ.-C. Ginefri
J.-C. Ginefri
JRJ.-S. Raynaud
J.-S. Raynaud
MPM. Poirier-Quinot
M. Poirier-Quinot
EDE. Dufour-Gergam
E. Dufour-Gergam
LDL. Darrasse
L. Darrasse