RAPIN Michaël

Dr. RAPIN Michaël

CSEM SA

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 July 2018 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
RMRAPIN Michaël
RAPIN Michaël
FBFabian Braun
Fabian Braun
AAAndy Adler
Andy Adler
JWJosias Wacker
Josias Wacker
IFInez Frerichs
Inez Frerichs
OCOlivier Chetelat
Olivier Chetelat
This paper presents a wearable sensor architecture for frequency-multiplexed electrical impedance tomography (EIT) and synchronous multilead electrocardiogram (ECG) data acquisition. The system is based on a novel electronic sensing architecture, called cooperative sensors, that significantly reduces the cabling complexity and enables flexible EIT stimulation and measurement patterns. The cooperative-sensor architecture was initially designed for ECG and has been extended for multichannel bioimpedance measurement. This approach allows for an adjustable EIT stimulation pattern via frequency-division multiplexing. This paper also shows a calibration procedure as well as EIT system noise performance assessment. Preliminary measurements on a healthy volunteer showed the ability of the wearable system to measure EIT data synchronously with multilead ECG. Ventilation-related and heartbeat-related EIT images were reconstructed, demonstrating the feasibility of the proposed architecture for noninvasive cardiovascular monitoring.

1 December 2015 in Critical Care
Verified
Journal Article
Open access
PDF file
CTConstantin J. C. Trepte
Constantin J. C. Trepte
CPCharles R. Phillips
Charles R. Phillips
JSJosep Solà
Josep Solà
AAAndy Adler
Andy Adler
SHSebastian A. Haas
Sebastian A. Haas
DRDaniel A. Reuter
Daniel A. Reuter
Background: Assessment of pulmonary edema is a key factor in monitoring and guidance of therapy in critically ill patients. To date, methods available at the bedside for estimating the physiologic correlate of pulmonary edema, extravascular lung water, often are unreliable or require invasive measurements. The aim of the present study was to develop a novel approach to reliably assess extravascular lung water by making use of the functional imaging capabilities of electrical impedance tomography. Methods: Thirty domestic pigs were anesthetized and randomized to three different groups. Group 1 was a sham group with no lung injury. Group 2 had acute lung injury induced by saline lavage. Group 3 had vascular lung injury induced by intravenous injection of oleic acid. A novel, noninvasive technique using changes in thoracic electrical impedance with lateral body rotation was used to measure a new metric, the lung water ratioEIT, which reflects total extravascular lung water. The lung water ratioEIT was compared with postmortem gravimetric lung water analysis and transcardiopulmonary thermodilution measurements. Results: A significant correlation was found between extravascular lung water as measured by postmortem gravimetric analysis and electrical impedance tomography (r = 0.80; p < 0.05). Significant changes after lung injury were found in groups 2 and 3 in extravascular lung water derived from transcardiopulmonary thermodilution as well as in measurements derived by lung water ratioEIT. Conclusions: Extravascular lung water could be determined noninvasively by assessing characteristic changes observed on electrical impedance tomograms during lateral body rotation. The novel lung water ratioEIT holds promise to become a noninvasive bedside measure of pulmonary edema.

8 September 2020 in Sensors
Verified
Journal Article
Open access
PDF file
GYGürkan Yilmaz
Gürkan Yilmaz
RMRAPIN Michaël
RAPIN Michaël
Diogo PessoaDiogo Pessoa
Diogo Pessoa
BRBruno Rocha
Bruno Rocha
ASAntonio Moreira de Sousa
Antonio Moreira de Sousa
OCOlivier Chételat
Olivier Chételat
Lung sounds acquired by stethoscopes are extensively used in diagnosing and differentiating respiratory diseases. Although an extensive know-how has been built to interpret these sounds and identify diseases associated with certain patterns, its effective use is limited to individual experience of practitioners. This user-dependency manifests itself as a factor impeding the digital transformation of this valuable diagnostic tool, which can improve patient outcomes by continuous long-term respiratory monitoring under real-life conditions. Particularly patients suffering from respiratory diseases with progressive nature, such as chronic obstructive pulmonary diseases, are expected to benefit from long-term monitoring. Recently, the COVID-19 pandemic has also shown the lack of respiratory monitoring systems which are ready to deploy in operational conditions while requiring minimal patient education. To address particularly the latter subject, in this article, we present a sound acquisition module which can be integrated into a dedicated garment; thus, minimizing the role of the patient for positioning the stethoscope and applying the appropriate pressure. We have implemented a diaphragm-less acousto-electric transducer by stacking a silicone rubber and a piezoelectric film to capture thoracic sounds with minimum attenuation. Furthermore, we benchmarked our device with an electronic stethoscope widely used in clinical practice to quantify its performance.

23 March 2015 in Physiological Measurement
Verified
Journal Article
Closed access
RMRAPIN Michaël
RAPIN Michaël
MPM Proença
M Proença
FBF Braun
F Braun
CMC Meier
C Meier
JSJ Solà
J Solà
OCO Chételat
O Chételat
Cooperative sensors is a novel measurement architecture that allows the acquiring of biopotential signals on patients in a comfortable and easy-to-integrate manner. The novel sensors are defined as cooperative in the sense that at least two of them work in concert to measure a target physiological signal, such as a multi-lead electrocardiogram or a thoracic bioimpedance. This paper starts by analysing the state-of-the-art methods to simultaneously measure biopotential and bioimpedance signals, and justifies why currently (1) passive electrodes require the use of shielded or double-shielded cables, and (2) active electrodes require the use of multi-wired cabled technologies, when aiming at high quality physiological measurements. In order to overcome the limitations of the state-of-the-art, a new method for biopotential and bioimpedance measurement using the cooperative sensor is then presented. The novel architecture allows the acquisition of the aforementioned biosignals without the need of shielded or multi-wire cables by splitting the electronics into separate electronic sensors comprising each of two electrodes, one for voltage measurement and one for current injection. The sensors are directly in contact with the skin and connected together by only one unshielded wire. This new configuration requires one power supply per sensor and all sensors need to be synchronized together to allow them to work in concert. After presenting the working principle of the cooperative sensor architecture, this paper reports first experimental results on the use of the technology when applied to measuring multi-lead ECG signals on patients. Measurements performed on a healthy patient demonstrate the feasibility of using this novel cooperative sensor architecture to measure biopotential signals and compliance with common mode rejection specification accordingly to international standard (IEC 60601-2-47) has also been assessed. By reducing the need of using complex wiring setups, and by eliminating the presence of central recording devices (cooperative sensors directly sense and store the measured biosignals on the site), the depicted novel technology is a candidate to a novel generation of highly-integrated, comfortable and reliable technologies that measure physiological signals in real-life scenarios.

24 April 2017 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
RMRAPIN Michaël
RAPIN Michaël
JWJosias Wacker
Josias Wacker
OCOlivier Chetelat
Olivier Chetelat
Classical approaches to make high-quality measurements of biopotential signals require the use of shielded or multiwire cables connecting the electrodes to a central unit in a star arrangement. As a consequence, increasing the number of leads increases cabling and connector complexity, which is not only limiting the patient comfort but is also anticipated as the main limiting factor to future miniaturization and cost reduction of tomorrow's wearables. We have recently introduced a novel sensing architecture that significantly reduces the cabling complexity by eliminating shielded or multiwire cables and by allowing simple connectors, thanks to a bus arrangement. In this architecture, electrodes are replaced by so-called cooperative sensors that require synchronous operation for systems larger than two sensors. This paper presents a novel full duplex body-sensor network based on a simple two-wire bus that combines biopotential measurements, synchronization, and gathering of data in a single cooperative sensor with a throughput up to 2 Mb/s. When compared to others, the suggested approach is advantageous as it keeps the cabling complexity at its minimum and does not require every sensor to be equipped with wireless communication capabilities. First experimental measurements demonstrated the reliability of the approach for a wearable 12-lead electrocardiogram monitoring system tested in real-life scenario.

1 January 2015
Verified
Conference Paper
Open access
RMRAPIN Michaël
RAPIN Michaël
JWJosias Wacker
Josias Wacker
OCOlivier Chételat
Olivier Chételat
Cooperative sensors are a novel measurement architecture based on active dry electrodes that allows the acquisition of biopotential signals (e.g., electrocardiogram, ECG) on patients in a comfortable and easy-to-integrate manner. This paper starts by analyzing the classical methods for measuring multilead ECG signals. Based on these classical methods, we then briefly introduce the concept of cooperative sensors and show how these sensors can be implemented in a wearable and reliable system that measures ECG signals in a real-life scenario. The main focus and innovation presented in this paper is on the duplex communication between the cooperative sensors. In addition, we show a first measurement of an ECG signal with cooperative sensors.